Search

234 results for “eye lens dose limit”, 52 in State rules.

Results

  1. State rules

    Oklahoma Radiation Safety Rules for Fluoroscopy Teams

    ALARA for X-ray users In part X-ray rule. Whole-body limit 5 rem (50 mSv) per year total effective dose equivalent. Eye-lens limit 150 mSv a year. Apron inspection Required

    orsif.org/guidelines/us/states/oklahoma

  2. State rules

    New Hampshire Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem) = 50 mSv per year total effective dose equivalent. Eye-lens limit 150 mSv a year. Apron inspection Not found. Alternatives to aprons In part

    orsif.org/guidelines/us/states/new-hampshire

  3. State rules

    Utah Radiation Safety Rules for Fluoroscopy Teams

    …uses X-ray machines, including fluoroscopy, to keep worker doses ALARA under R313-15-101, a rule shared with radioactive-materials licensees and cross-referenced by the X-ray registration rules, and…

    orsif.org/guidelines/us/states/utah

  4. State rules

    California Radiation Safety Rules for Fluoroscopy Teams

    …Branch regulates X-ray in California, and staff ALARA and dose limits come from 17 CCR § 30253, which adopts 10 CFR Part 20 as of January 1, 2021 and applies it to all users, including X-ray…

    orsif.org/guidelines/us/states/california

  5. State rules

    Ohio Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem) = 50 mSv per year total effective dose equivalent (TEDE). Eye-lens limit 150 mSv a year. Apron inspection Required. Alternatives to aprons In part

    orsif.org/guidelines/us/states/ohio

  6. State rules

    Kansas Radiation Safety Rules for Fluoroscopy Teams

    …X-ray registrants alike and contain the ALARA requirement. Dose limits follow the federal model: 50 mSv whole body, 150 mSv lens of the eye, 500 mSv skin or extremities, and 5 mSv to the embryo/fetus.…

    orsif.org/guidelines/us/states/kansas

  7. State rules

    Mississippi Radiation Safety Rules for Fluoroscopy Teams

    …is unsettled. Fluoroscopy workers have the federal dose limits, including the 150 mSv/year lens limit. Staff must be protected by aprons 'or whole body protective barriers' of at least 0.25 mm lead…

    orsif.org/guidelines/us/states/mississippi

  8. State rules

    Arkansas Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 5 rems (50 mSv) per year total effective dose equivalent (TEDE). Eye-lens limit 150 mSv a year. Apron inspection Not found. Alternatives to aprons In part

    orsif.org/guidelines/us/states/arkansas

  9. State rules

    Massachusetts Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem) = 50 mSv total effective dose equivalent (TEDE) per year; applies to registrants as well as licensees. Eye-lens limit 150 mSv a year

    orsif.org/guidelines/us/states/massachusetts

  10. State rules

    Maine Radiation Safety Rules for Fluoroscopy Teams

    …ALARA only in its quality assurance (QA) appendix. Dose limits follow the NRC model: 50 mSv whole body, 150 mSv lens (the International Commission on Radiological Protection (ICRP)'s lower limit has…

    orsif.org/guidelines/us/states/maine

  11. State rules

    Washington Radiation Safety Rules for Fluoroscopy Teams

    …exposure. Fluoroscopy workers share the materials dose limits: 50 mSv whole body, 150 mSv lens, 500 mSv skin and extremities, and 5 mSv embryo/fetus. Everyone working in a fluoroscopy room must wear a…

    orsif.org/guidelines/us/states/washington

  12. State rules

    Maryland Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit Total effective dose equivalent of 0.05 Sv (5 rem), which is 50 mSv per year. Eye-lens limit 150 mSv a year. Apron inspection Not found. Alternatives to aprons In part

    orsif.org/guidelines/us/states/maryland

  13. State rules

    Vermont Radiation Safety Rules for Fluoroscopy Teams

    …which adopts 10 CFR Part 20 by reference, and its worker dose limits match the NRC's: 50 mSv whole body, 150 mSv lens of the eye, 500 mSv skin and extremities, and 5 mSv to the fetus of a declared…

    orsif.org/guidelines/us/states/vermont

  14. State rules

    Michigan Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem), or 50 mSv per year, effective dose equivalent. Eye-lens limit 150 mSv a year. Apron inspection Not found. Alternatives to aprons Not found

    orsif.org/guidelines/us/states/michigan

  15. State rules

    South Carolina Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 5 rem (0.05 Sv), or 50 mSv, total effective dose equivalent (TEDE) per year. Eye-lens limit 150 mSv a year. Apron inspection Required. Alternatives to aprons In part

    orsif.org/guidelines/us/states/south-carolina

  16. State rules

    Wisconsin Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem) = 50 mSv per year total effective dose equivalent for adults. Eye-lens limit 150 mSv a year. Apron inspection Required. Alternatives to aprons In part

    orsif.org/guidelines/us/states/wisconsin

  17. State rules

    Kentucky Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 5 rem (50 mSv) total effective dose equivalent (TEDE) per year for adults. Eye-lens limit 150 mSv a year. Apron inspection Not found. Alternatives to aprons Not found

    orsif.org/guidelines/us/states/kentucky

  18. State rules

    Nevada Radiation Safety Rules for Fluoroscopy Teams

    …could affect fluoroscopy rules. Nevada uses the federal dose limits of 50 mSv whole body, 150 mSv lens of the eye, 500 mSv skin and extremities, and 5 mSv over a pregnancy for a declared pregnant…

    orsif.org/guidelines/us/states/nevada

  19. State rules

    Arizona Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem) = 50 mSv total effective dose equivalent (TEDE) per year. Eye-lens limit 150 mSv a year. Apron inspection Required. Alternatives to aprons Addressed

    orsif.org/guidelines/us/states/arizona

  20. State rules

    Louisiana Radiation Safety Rules for Fluoroscopy Teams

    …X-ray chapter (Chapter 6) has no ALARA wording of its own. Dose limits follow the federal model: 50 mSv per year whole body, 150 mSv per year to the lens of the eye (the lower 20 mSv lens limit has…

    orsif.org/guidelines/us/states/louisiana