Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Wisconsin Department of Health Services (DHS), Division of Public Health, Radiation Protection Section as the agency that regulates X-ray and fluoroscopy equipment in Wisconsin. Wisconsin is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Wisconsin's ALARA requirement is in shared DHS 157.21, which covers X-ray registrants, and the X-ray chapter adds its own minimize-exposure language. Dose limits are 50 mSv whole body and 150 mSv lens; the lower 20 mSv lens limit has not been adopted. All fluoroscopy operators must wear a dosimeter, and the rule sets apron badge placement and dose formulas. Facilities must supply protective garments and X-ray them for defects every 2 years. Engineered alternatives to aprons are not addressed. Licensed practitioners or trained technologists under supervision may operate fluoroscopy. Pending CR 26-033 would rewrite the operator and supervision language.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Wisconsin an NRC Agreement State?

Yes

Yes. Wisconsin is an Agreement State; its agreement took effect August 11, 2003.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; DHS Radiation Protection page
Source
nrc.gov
dhs.wisconsin.gov
What it says
Wisconsin became the 33rd agreement state effective August 11, 2003.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Wisconsin?

Yes

All radiation rules are in Wis. Admin. Code ch. DHS 157. General standards are in Subchapter III (DHS 157.20-157.33), X-ray rules are in Subchapter VIII (DHS 157.74-157.86), and fluoroscopy is in DHS 157.76. The official text was read only through excerpts and secondary copies. The DHS version note appears internally inconsistent.

Rule text and source
Rule
ch. DHS 157, Subch. III and VIII
Source
dhs.wisconsin.gov
law.cornell.edu
What it says
Rules are specified in Wis. Admin. Code ch. DHS 157
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Wisconsin require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes. DHS 157.21(2) applies to licensees and registrants, including X-ray facilities, and requires procedures and engineering controls that keep occupational doses ALARA. The radiation protection program must be reviewed at least every 13 months.

Where ALARA lives in Wisconsin: In a shared rule and in X-ray-specific language. The ALARA requirement is in shared Subchapter III (DHS 157.21), which applies to licensees and registrants. The X-ray chapter separately requires procedures to minimize personnel exposure (DHS 157.74(2)(h)) without using the term ALARA. DHS 157.74(2)(i) cross-references the dose limits but not 157.21. Because 157.21 is shared, NRC-driven changes could reach X-ray registrants. (DHS 157.21(2); DHS 157.74(2)(h)-(i))

Rule text and source
Rule
DHS 157.21(2); DHS 157.03(27)
Source
docs.legis.wisconsin.gov
What it says
to achieve occupational doses and doses to members of the public that are as low as is reasonably achievable.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual eye-lens dose limit in Wisconsin?

Yes

0.15 Sv (15 rem) = 150 mSv per year. Wisconsin has not adopted a lower lens limit, and the pending CR 26-033 draft does not appear to change it.

Rule text and source
Rule
DHS 157.22(1)(a)
Source
docs.legis.wisconsin.gov
What it says
A lens dose equivalent of 0.15 Sv (15 rem).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Wisconsin?

Yes

5 mSv (500 mrem) to the embryo/fetus of a declared pregnant woman over the whole pregnancy, with efforts to avoid large month-to-month variation.

Rule text and source
Rule
DHS 157.22(8)(a)
Source
mcw.edu

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Wisconsin wear a dosimeter?

Yes

A dosimeter is required for adults likely to exceed 10% of a limit, for minors and declared pregnant women above lower thresholds (1 mSv for a declared pregnant woman), for anyone entering a high radiation area, and for every individual operating medical fluoroscopic equipment regardless of projected dose. Dosimeters must be individually assigned and not shared. CR 26-033 would delete the badge-exchange language.

Rule text and source
Rule
DHS 157.25(2)(a)1.-5.
Source
docs.legis.wisconsin.gov
What it says
5. An individual operating medical fluoroscopic equipment.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Wisconsin when a protective apron is worn?

YesLess certain

When an apron is worn, the badge goes at the neck (collar) outside the apron, with an optional second badge under the apron at the waist. Two-badge formula: HE = 1.5 HW + 0.04 HN. With one badge, the deep dose counts as the effective dose if exposure is under 25% of a limit; above 25%, it is the deep dose × 0.3. DHS may approve other methods. A ring badge is required for an unprotected hand in the beam unless clinically contraindicated.

Rule text and source
Rule
DHS 157.25(3)(b); DHS 157.22(1)(c)1.-2.
Source
mcw.edu
What it says
If a protective apron is worn, the individual monitoring device shall be located at the neck, which is the collar.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Wisconsin fluoroscopy rooms wear protective aprons or other apparel?

In part

At least 0.5 mm lead equivalent is required for body parts in the useful beam. Others must be behind whole body protective barriers of at least 0.25 mm lead equivalent or stay at least 2 m away. Operators of C-arms at 0.2 mA or less are exempt from wearing an apron if they wear a dosimeter, which implies an apron requirement otherwise. Facilities must supply enough garments for personnel otherwise not shielded. There is no explicit thyroid-shield requirement for fluoroscopy, and no eyewear requirement was found.

Rule text and source
Rule
DHS 157.74(2)(d)1.-3., (g)3. and Note
Source
law.cornell.edu
What it says
0.2 mA are exempt from the requirement to wear a leaded apron, provided the operator wears a personal dosimeter
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Wisconsin require protective aprons to be inspected?

Yes

Garments must be inspected fluoroscopically or radiographically at least every 2 years and replaced if defective. A visual inspection showing possible defects triggers a radiographic or fluoroscopic inspection.

Rule text and source
Rule
DHS 157.74(2)(g)4.-5.
Source
law.cornell.edu
What it says
shall be fluoroscopically or radiographically inspected at least every 2 years for defects and replaced if defective.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Wisconsin address engineered protection systems used in place of aprons?

UnclearLess certain

Not addressed. The rules require whole body protective barriers or distance, and the garment-supply rule covers personnel 'otherwise not shielded'. Whether an engineered system counts as a barrier is not stated. CR 26-033 would change 'leaded shielding garments' to 'radiation protective garments and devices'.

Rule text and source
Rule
DHS 157.74(2)(d)2., (g)3.
Source
docs.legis.wisconsin.gov
What it says
shall be protected from the direct scatter radiation by whole body protective barriers of not less than 0.25 millimeter lead equivalent material
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Wisconsin?

In partLess certain

A licensed practitioner or a radiologic technologist trained in fluoroscopy may operate. Technologists work under a licensed practitioner's supervision, and students need direct supervision. Diagnostic X-ray operators need a radiography license or LXMO permit, with statutory exemptions for physicians, PAs, chiropractors, dentists and dental staff, podiatrists, and supervised students. The LXMO scope does not include fluoroscopy. Nurse practitioners are not exempt; SB 281/AB 295 failed. 'Licensed practitioner' was not defined in the retrieved text.

Rule text and source
Rule
DHS 157.76(11)(a)-(c); DHS 157.74(2)(m); Wis. Stat. 462.02(2)
Source
law.cornell.edu
What it says
only a licensed practitioner or a radiologic technologist who is trained in the safe use of fluoroscopic x-ray systems is allowed to operate these systems.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Wisconsin require to operate fluoroscopy equipment?

Yes

Fluoroscopy operators must be ABR-certified or board eligible, or have completed training covering specified topics. No hours are specified and there is no state fluoroscopy permit. Radiographers need the American Registry of Radiologic Technologists (ARRT) exam or certification and 24 continuing education (CE) hours every two years; LXMO holders need 12 CE hours every two years. No annual training requirement was found.

Rule text and source
Rule
DHS 157.76(11)(e); RAD 2.03; RAD 5.01
Source
law.cornell.edu
What it says
Is certified by the American Board of Radiology or board eligible.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Proposed ruleCR 26-033 (DHS 157 revision, Statement of Scope SS 069-24)

    Sent to Rules Clearinghouse 6/22/26; public hearing 9/25/26; comments closed 10/2/26; scope expires 12/24/26; no later status found (Sep 25, 2026)

    Would require fluoroscopy operators to be authorized under ch. 462 and specifically trained; technologists would work under direct supervision and students under personal supervision; 'leaded shielding' would become 'radiation protective garments and devices'; the badge-exchange language would be deleted. No ALARA or lens-limit changes found.

    Source: dhs.wisconsin.gov

  • BillSB 281 / AB 295 (advanced practice nurse prescribers and radiography)

    Failed to pass (Mar 23, 2026)

    Would have added advanced practice nurses to the radiographer licensing exemptions.

    Source: docs.legis.wisconsin.gov

1 other item the research logged (radiation therapy, industrial machines, fees and other subjects)
  • Adopted ruleCR 22-015

    Effective 7/1/2023 (Jul 1, 2023)

    Set program review at 13 months, amended parts of DHS 157.74 and 157.76, and repealed patient gonad shielding (DHS 157.74(2)(e)).

    Source: dhs.wisconsin.gov

Also worth knowing

  • Hospitals must have registered facilities inspected at least every 2 years and fix identified hazards within 30 days (DHS 157.74(5)).
  • Typical and maximum air kerma must be measured annually (DHS 157.76(12)).
  • Newer fluoroscopy units must display irradiation time and give an audible 5-minute signal (DHS 157.76(7)).
  • A ring badge is required for unprotected hands in the beam.
  • Radioactive-materials provisions must be kept compatible with NRC rules within three years of a federal change, which matters for the shared DHS 157.21.
  • DHS issued an updated employee notice, P-45027, dated 10/2025.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Confirm that DHS 157.25(2)(a)5., 157.25(3)(b) and 157.22(1)(c)2. are unchanged in the current official text.
  • The DHS 157.03 definition of 'licensed practitioner' was not retrieved.
  • Whether proposed DHS 157.76(11)(a) narrows out any group currently allowed (e.g., nurse practitioners); check the Clearinghouse report (https://docs.legis.wisconsin.gov/code/chr/active).
  • CR 26-033 status after the 10/2/2026 comment deadline and before the scope expires 12/24/26.
  • Whether DHS treats engineered shielding systems as 'whole body protective barriers'; ask DHSXray@dhs.wisconsin.gov.
  • Whether the DHS 157.74(2)(d) room-presence rule applies to fluoroscopy.
  • The source of the two-badge formula was not verified.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 1 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 3 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ARRT
American Registry of Radiologic Technologists