Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Radiation Control Section, Arkansas Department of Health as the agency that regulates X-ray and fluoroscopy equipment in Arkansas. Arkansas is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Arkansas requires X-ray registrants to keep worker doses ALARA under RH-1004.b, in a section shared with radioactive-materials licensees. Part G adds a duty to 'minimize patient and personnel exposure' without using the term ALARA. Dose limits follow the federal model: 50 mSv whole body, 150 mSv lens, 500 mSv skin and extremities. All fluoroscopy workers must wear dosimeters, and staff must be protected by aprons or barriers of at least 0.25 mm lead equivalent. Apron inspection and apron alternatives are not addressed. Fluoroscopy may be operated by licensed practitioners, radiologic technologists and two supervised cardiac specialist licenses. A major revision adding training hours, annual apron checks and effective-dose formulas passed subcommittee review on June 15, 2026, but its effective date is unconfirmed.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Arkansas an NRC Agreement State?

Yes

Yes. Arkansas is not on the list of non-Agreement jurisdictions, so it is an Agreement State.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; Ark. Code Ann. § 20-21-207(a)(3), as quoted in the legislature's review packet
Source
nrc.gov
arkleg.state.ar.us
What it says
The State Board of Health is the designated State Radiation Control Agency for Arkansas
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Arkansas?

Yes

Rules for Control of Sources of Ionizing Radiation, 20 CAR pt. 3 (revision effective September 14, 2024). Section 3 holds the general protection standards (RH-1000 onward), and Part G (RH-1600 to RH-1613) holds the X-ray rules, with fluoroscopy at RH-1603. A pending revision would move Part G into a new Section 10.

Rule text and source
Rule
20 CAR pt. 3; RH-1002, RH-1600
Source
codeofarrules.arkansas.gov
What it says
This Part establishes requirements, for which a registrant (or licensee) is responsible, for use of x-ray equipment by or under the supervision of an individual authorized by and licensed in accordance with state statutes to engage in the healing arts
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Arkansas require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes. RH-1004.b requires every licensee or registrant to achieve ALARA occupational doses, and the ALARA definition names x-ray equipment use explicitly.

Where ALARA lives in Arkansas: Only in a rule shared with radioactive materials. The explicit ALARA requirement is in RH-1004.b in Section 3, which covers radioactive-materials licensees and X-ray registrants together. Part G requires procedures to 'minimize patient and personnel exposure' (RH-1602.a.9) but does not use the term ALARA. (RH-1004.b; RH-1602.a.9; RH-1602.a.10)

Rule text and source
Rule
RH-1004.a-b; RH-1100 (definition of ALARA)
Source
codeofarrules.arkansas.gov
What it says
The licensee or registrant shall use, to the extent practical, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and doses to members of the public that are as low as is reasonably achievable (ALARA).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual eye-lens dose limit in Arkansas?

Yes

15 rems (150 mSv) per year. No lower limit has been adopted, and the May 2026 draft keeps 15 rems.

Rule text and source
Rule
RH-1200.a
Source
codeofarrules.arkansas.gov
What it says
An lens dose equivalent of 15 rems (0.15 Sv), and … A shallow-dose equivalent of 50 rems (0.50 Sv) to the skin of the whole body or to skin of any extremity.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Arkansas?

Yes

50 rems (500 mSv) shallow-dose equivalent to the skin of the whole body or any extremity.

Rule text and source
Rule
RH-1200.a
Source
codeofarrules.arkansas.gov
What it says
An lens dose equivalent of 15 rems (0.15 Sv), and … A shallow-dose equivalent of 50 rems (0.50 Sv) to the skin of the whole body or to skin of any extremity.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Arkansas wear a dosimeter?

Yes

Monitoring is required for adults likely to exceed 10% of a limit and for declared pregnant women likely to exceed 0.1 rem (1 mSv). Everyone working with medical fluoroscopy equipment must be monitored, with no dose threshold.

Rule text and source
Rule
RH-1302.a.1, a.3, a.5
Source
codeofarrules.arkansas.gov
What it says
Adults likely to receive, in one (1) year from sources external to the body, a dose in excess of ten percent (10%) of the limits in RH-1200.a; … 5. Individuals working with medical fluoroscopic equipment.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Arkansas when a protective apron is worn?

Yes

A single badge is worn at the collar outside the apron. A second badge, if used, is worn under the apron at the waist and is required for a declared pregnant woman. A lens badge is worn at the collar or closer to the eye. The current rule names no effective-dose method beyond a Department-approved method. Proposed RH-1200.d would add formulas: 0.3 × deep dose with one badge above 25% of the limit, and 1.5 × waist + 0.04 × collar with two badges.

Rule text and source
Rule
RH-1302.a.5.A-C; RH-1311; RH-1200.c; proposed RH-1200.d
Source
codeofarrules.arkansas.gov
arkleg.state.ar.us
What it says
When only 1 individual monitoring device is used to determine the effective dose equivalent for external radiation, it shall be located at the neck (collar) outside the protective apron.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Arkansas fluoroscopy rooms wear protective aprons or other apparel?

Yes

Staff must be protected by aprons or whole-body barriers of at least 0.25 mm lead equivalent, and aprons and gloves must be available in sufficient numbers. In fluoroscopy, drapes or curtains are required in addition to the apron, or staff must stand at least 120 cm from the beam. Thyroid shields and eyewear are not required.

Rule text and source
Rule
RH-1602.a.5.B; RH-1602.a.8.B.vi; RH-1603.f; RCG 2.2
Source
codeofarrules.arkansas.gov
healthy.arkansas.gov
What it says
Staff and ancillary personnel shall be protected from the direct scatter radiation by protective aprons or whole body protective barriers of not less than 0.25 millimeter lead equivalent.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Arkansas require protective aprons to be inspected?

Not found

not found. The current rules have no apron inspection requirement. Proposed RH-9200.g would require an annual integrity check and lead-equivalence labels.

Rule text and source
Rule
Proposed RH-9200.g (May 15, 2026 draft)
Source
healthy.arkansas.gov
What it says
All protective apparel and auxiliary shields shall be evaluated annually for integrity and clearly labeled with their lead equivalence.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Arkansas address engineered protection systems used in place of aprons?

Not foundLess certain

Not addressed. No current or proposed provision deals with engineered systems used in place of aprons. The closest are the 'whole body protective barriers' option and the general reference to engineering controls.

Rule text and source
Rule
RH-1603.f.2; proposed RH-9305.k.1
Source
codeofarrules.arkansas.gov
arkleg.state.ar.us
What it says
The material may be, but is not limited to, drapes, self-supporting curtains, or viewing shields, in addition to any lead equivalency provided by a protective apron.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Arkansas?

YesLess certain

Licensed practitioners (medicine, osteopathy, dentistry, podiatric medicine, chiropractic, optometry), licensed radiologic technologists, and Invasive Cardiovascular and Cardiac Electrophysiology Specialists under supervision may operate fluoroscopy. Limited licensees may not. Physician assistants and nurse practitioners are not listed.

Rule text and source
Rule
17 CAR §§ 49-102(24), (27); 49-103(a)-(b); 49-105(d)-(e); RH-1603.i.1
Source
codeofarrules.arkansas.gov
What it says
No person, other than a licensed practitioner, radiologic technologist, licensed technologist, or limited licensed technologist shall use radioactive materials or medical equipment emitting or detecting ionizing radiation on human beings for diagnostic or therapeutic purposes.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Arkansas require to operate fluoroscopy equipment?

In part

The current radiation rule requires only that operators be 'adequately instructed' and competent, with no set hours. Technologists need a national registry, and specialists need a committee-approved exam. Pending RH-9305.l would require 4 hours of fluoroscopy training (8 for fluoroscopically guided interventional (FGI), including 1 hour hands-on) and 2 hours every 2 years.

Rule text and source
Rule
RH-1602.a.2; 17 CAR § 49-102(48); proposed RH-9305.l
Source
codeofarrules.arkansas.gov
arkleg.state.ar.us
What it says
All persons operating, or supervising the operation of, fluoroscopy systems during fluoroscopically-guided interventional (FGI) procedures shall have completed a minimum of eight (8) hours of training approved by the Department.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Adopted rule17 CAR pt. 49 (technologist licensing)

    Amended effective August 13, 2026 (Ark. R. 2026-92)

    Updated 'two limited scope radiation modalities,' apparently the Invasive Cardiovascular and Cardiac Electrophysiology Specialist licenses (this research's inference).

  • Proposed rule20 CAR pt. 3, Rules for Control of Sources of Ionizing Radiation (July 2025 package)

    Approved by ALC Administrative Rules Subcommittee June 15, 2026; effective date not confirmed

    Moves Part G to a new Section 10. Adds effective-dose formulas under aprons, annual apparel integrity checks, aprons for everyone in sterile-field cases, 4- and 8-hour fluoroscopy training, a written patient-dose policy, qualified-expert evaluations, an FGI Radiation Protocol Committee and skin-dose misadministration reporting. Removes gonadal shielding. Lens limit stays at 15 rems and ALARA stays in RH-1004.b.

    Source: arkleg.state.ar.us

Also worth knowing

  • Dosimeters are required for all fluoroscopy workers regardless of expected dose (RH-1302.a.5).
  • Estimated patient doses must be logged for listed interventional, cardiac and electrophysiology procedures. Skin doses above 300 rad (adults) or 100 rad (children) must be reviewed by the radiation safety committee or explained to the Department within 30 days (RH-1603.h).
  • A qualified expert must measure entrance exposure rates annually (RH-1603.j).
  • The Department applies a 14-month window to 'annual' surveys.
  • Guidance RCG 2.2 says workers should be told each year if their exposure exceeded 100 mrem.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Effective date of the 20 CAR pt. 3 revision: check the Arkansas Register or call ADH Radiation Control, and compare the final text with Exhibit T.
  • Whether physician assistants and nurse practitioners may operate fluoroscopy: read Ark. Code § 17-106-111 and the State Medical Board's PA rules.
  • Hospital-rule limit on technologists performing fluoroscopy (Section 20 A.6): check the Rules for Hospitals and Related Institutions (20 CAR pt. 41).
  • Approved effective-dose methods under RH-1200.c: no published approval (e.g., of National Council on Radiation Protection and Measurements (NCRP) 122) was found.
  • Technologist continuing education: the 6-hour figure was found only in suspension and lapse provisions, so the renewal section of 17 CAR pt. 49 should be read directly.
  • Two differing versions of § 49-105: confirm against the Ark. R. 2026-92 filing.
  • Whether Arkansas would keep ALARA for X-ray users if NRC changes force edits to Section 3.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

  • The rule itself. Open "Rule text and source" under any answer, or read the sources listed below.
  • The state. Radiation Control Section. Program contacts in the CRCPD directory.
  • Your radiation safety officer. They know the federal, accreditation and facility requirements that apply at your site, which the state rules do not cover.

What may be missing here

  • 2 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 2 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
NCRP
National Council on Radiation Protection and Measurements
TEDE
Total effective dose equivalent
FGI
Fluoroscopically guided interventional