Is New Hampshire an NRC Agreement State?
Yes. New Hampshire is an NRC Agreement State, with its agreement dating from May 16, 1966.
What New Hampshire's rules say about ALARA (as low as reasonably achievable), dose limits in millisieverts (mSv), dosimeters, aprons and training for the people who work in fluoroscopy labs.
Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made
ORSIF's research identified the NH Department of Health and Human Services, Division of Public Health Services, Radiological Health Section (DHHS/RHS), Radiation Machines Program as the agency that regulates X-ray and fluoroscopy equipment in New Hampshire. New Hampshire is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.
New Hampshire's ALARA requirement is in He-P 4020.04(b), a unified part covering both materials licensees and X-ray registrants. He-P 4045.03(p) applies He-P 4020-4022 to all X-ray workers. Occupational dose limits match the federal ones: 50 mSv whole body, 150 mSv lens, 500 mSv skin/extremities, and 5 mSv to the embryo/fetus. Scatter protection may come from either aprons or whole-body barriers of at least 0.5 mm lead equivalent; engineered systems are not named. Limited operators are barred from fluoroscopy. The main X-ray parts (He-P 4045 except 4045.03, and He-P 4046) showed a 7-21-25 expiration with no readoption found, so their current status needs confirmation.
Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.
Which rules apply, and whether ALARA is among them.
Yes. New Hampshire is an NRC Agreement State, with its agreement dating from May 16, 1966.
Yes. Chapter He-P 4000 contains the general standards (He-P 4019-4022) and the machine rules (He-P 4040, 4041, 4045, 4046). Fluoroscopy is covered at He-P 4046.02-4046.05. He-P 4020 was readopted effective 7-23-24. The current status of He-P 4045/4046 is uncertain.
He-P 4020 through He-P 4023 establish standards for protection against ionizing radiation resulting from activities conducted pursuant to licenses or registrations issued by the department of health and human services radiological health section (DHHS/RHS).This quote was matched word for word to the source page.
Yes. Licensees and registrants must use procedures and engineering controls to keep occupational and public doses ALARA, run a radiation protection program, and review it at least every 12 months.
Where ALARA lives in New Hampshire: Only in a rule shared with radioactive materials. ALARA is in He-P 4020.04(b), a unified part applying to both materials licensees and machine registrants. He-P 4045.03(p) applies He-P 4020-4022 to everyone associated with X-ray operation. No separate X-ray occupational-ALARA language was found, though He-P 4046.03-.05 were not read. (He-P 4020.02; He-P 4045.03(p))
The licensee or registrant shall use procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are as low as is reasonably achievable (ALARA).This quote was matched word for word to the source page.
The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.
0.05 Sv (5 rem) = 50 mSv per year total effective dose equivalent. Any single organ or tissue other than the lens is limited to 500 mSv.
0.15 Sv (15 rem) = 150 mSv per year. No lower International Commission on Radiological Protection (ICRP)-style limit has been adopted.
A lens-dose equivalent of 0.15 Sv (15 rem); and b. A shallow-dose equivalent of 0.5 Sv (50 rem) to the skin of the whole body or to the skin of any extremity.This quote was matched word for word to the source page.
0.5 Sv (50 rem) = 500 mSv shallow-dose equivalent to the skin or any extremity.
A lens-dose equivalent of 0.15 Sv (15 rem); and b. A shallow-dose equivalent of 0.5 Sv (50 rem) to the skin of the whole body or to the skin of any extremity.This quote was matched word for word to the source page.
5 mSv (0.5 rem) to the embryo/fetus of a declared pregnant woman for the whole pregnancy.
When a worker must wear a dosimeter, and where.
not found
If the licensee or registrant shall monitor pursuant to He-P 4022.02(a), (b), and (c), the licensee or registrant shall demonstrate compliance with the dose limits by summing external and internal doses.This quote was matched word for word to the source page.
With a single dosimeter at the neck outside the apron, the deep-dose reading is reported as the effective dose equivalent. Otherwise deep-dose equivalent is used unless the effective dose is determined by a dosimetry method acceptable to DHHS/RHS. No named two-badge method was found, and He-P 4022.03 was not read.
when one individual monitoring device is used and it is located at the neck outside the protective apron, the reported deep-dose equivalent shall be the effective dose equivalent for external radiationThis quote was matched word for word to the source page.
Protective apparel, how it is checked, and whether other systems are addressed.
Yes. Everyone in the room except the patient must be protected from scatter by aprons or whole-body barriers of at least 0.5 mm lead equivalent. Enough garments or barriers must be provided, and each must be labeled with its lead equivalence. No thyroid shield or eyewear requirement was found.
shall be protected from scatter radiation by either protective aprons or whole body protective barriers, of not less than 0.5 millimeter lead equivalent material.This quote was matched word for word to the source page.
not found
All protective apparel or barriers shall be clearly labeled with its lead equivalence.This quote was matched word for word to the source page.
Addressed indirectly. Whole-body protective barriers of at least 0.5 mm lead equivalent are accepted as an alternative to aprons. Engineered radiation protection systems are not mentioned by name.
shall be protected from scatter radiation by either protective aprons or whole body protective barriers, of not less than 0.5 millimeter lead equivalent material.This quote was matched word for word to the source page.
Who may use fluoroscopy equipment and what training the rules ask for.
Partly found. RSA 328-J requires a license to perform medical imaging, and limited X-ray machine operators may not perform fluoroscopy. Students and residents may perform imaging under supervision. Physician, PA and NP exemptions were not verified.
Partly found. Operators must be instructed in the manufacturer's safe operating procedures and be competent. Diagnostic operators must show competence in listed areas, including personnel protection and dosimetry. American Registry of Radiologic Technologists (ARRT), fluoroscopy permit, training-hour and continuing-education requirements were not verified.
Persons who operate radiation or MRI machines shall be instructed in the manufacturer's safe operating procedures and be competent in the safe use of the equipment.This quote was matched word for word to the source page.
Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.
Effective 7-23-24 (#14028)
Standards for Protection Against Radiation readopted. This contains the ALARA text (He-P 4020.04(b)) that would be relevant if NH matches the NRC proposed ALARA change.
Last readopted effective 7-21-15 with listed expiration 7-21-25; no later readoption shown in filing history; status unsettled
Main X-ray parts may have expired or may remain in force while a readoption is pending.
Interim rule effective 4-24-26, expiring 10-21-26 (#14566); unclear whether replaced by a final rule
Interim registration rule.
Interim rule effective 4-22-26, expiring 10-19-26 (#14562); unclear whether replaced by a final rule
Interim fees rule.
Effective 7-1-25 (#14303)
Surveys and monitoring part readopted with amendments.
Effective 7-1-25 (#14301, #14300)
Notices/instructions to workers and definitions readopted.
Effective 8-8-25 (#14336)
He-P 4043 readopted.
Questions the research could not settle. If you know the answer, tell us.
ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.
Found something wrong or missing? Tell ORSIF.
Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.