Is Nevada an NRC Agreement State?
Yes. Nevada is an NRC Agreement State.
Rule text and source
- Rule
- NRC list of Agreement States, updated October 29, 2026
- Source
- nrc.gov
What Nevada's rules say about ALARA (as low as reasonably achievable), dose limits in millisieverts (mSv), dosimeters, aprons and training for the people who work in fluoroscopy labs.
Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made
ORSIF's research identified the Radiation Control Program (RCP), Nevada Division of Public and Behavioral Health (DPBH), Department of Health and Human Services as the agency that regulates X-ray and fluoroscopy equipment in Nevada. Nevada is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.
Nevada's radiation rules are in NAC Chapter 459. One shared set of Standards for Protection Against Radiation (NAC 459.320-459.374) covers both radioactive-materials licensees and X-ray registrants, and it holds the only clear ALARA requirement found for X-ray users, so a federal NRC change to ALARA could affect fluoroscopy rules. Nevada uses the federal dose limits: 50 mSv whole body, 150 mSv lens of the eye, 500 mSv skin and extremities, and 5 mSv over a pregnancy for a declared pregnant worker. Workers must be monitored if they are likely to exceed 10% of a limit, and the dosimeter goes at the collar outside the apron. Staff must use 0.25 mm lead-equivalent aprons or barriers, or keep their distance. Engineered alternatives to aprons are not addressed. Under NRS 653, fluoroscopy may be performed by American Registry of Radiologic Technologists (ARRT)-certified licensed technologists, by grandfathered persons, or under narrow exceptions. Several 2025-2026 draft rules are pending, and their adoption is unconfirmed.
Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.
Which rules apply, and whether ALARA is among them.
Yes. Nevada is an NRC Agreement State.
All rules are in NAC Chapter 459: general applicability NAC 459.118; Standards for Protection Against Radiation NAC 459.320-459.374 (all licensees and registrants); X-rays in the Healing Arts NAC 459.400-459.624, with fluoroscopy at NAC 459.566-459.578; employee notices NAC 459.780-459.794.
Yes, with a caveat. NAC 459.320(3) requires licensees and registrants to keep exposures ALARA. The wording pairs exposures with effluent releases, so its reach to occupational X-ray exposure is a matter of interpretation. The ALARA definition expressly includes registered activities.
Where ALARA lives in Nevada: Only in a rule shared with radioactive materials. The ALARA requirement (459.320(3)) and its definition (459.0205) sit in sections that apply to both materials licensees and X-ray registrants. No X-ray-specific ALARA wording was found in the X-ray sections read, but NAC 459.556 was not checked. A federal change could reach X-ray registrants through these shared rules. (NAC 459.320(2)-(3); NAC 459.0192)
a licensee or registrant shall make every reasonable effort to maintain exposures and releases of radioactive materials in effluents to unrestricted areas, as low as is reasonably achievable.This quote was matched word for word to the source page.
The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.
Total effective dose equivalent of 5 rems (50 mSv) per year.
15 rems (150 mSv) per year. No lower limit has been adopted.
50 rems (500 mSv) per year to the skin of the whole body or any extremity.
0.5 rem (5 mSv) to the embryo over the entire pregnancy for a woman who has declared her pregnancy.
When a worker must wear a dosimeter, and where.
Adults likely to receive more than 10% of any NAC 459.325 limit in a year from external sources must be monitored. Minors must be monitored above 0.1 rem deep dose, 0.15 rem lens dose, or 0.5 rem skin or extremity dose. Declared pregnant women are also covered.
When an apron is worn, at least one dosimeter goes at the collar outside the apron. The recorded whole-body dose is the highest dose to any critical organ. No two-badge or effective-dose calculation method was found; the 2015 DPBH dosimetry bulletin was not read.
Protective apparel, how it is checked, and whether other systems are addressed.
Staff must wear aprons or use whole-body barriers of at least 0.25 mm lead equivalent, or stand at a set distance (at least 2 meters, per a search excerpt). NAC 459.578 adds fluoroscopy scatter shielding below and above the table. No general thyroid-shield or eyewear requirement was found.
protective aprons or whole body protective barriers of not less than 0.25 mm lead equivalent.This quote was matched word for word to the source page.
not found
Engineered systems that replace aprons are not addressed. Whole-body protective barriers are an alternative to aprons, and the Division may grant exceptions to the above-table barrier rule where a sterile field prevents their use.
Upon application to the Division with adequate justification, exceptions to subsection 2 may be made in some special procedures where a sterile field will not permit the use of the normal protective barriers or where the protective barriers would interfere with the procedures.This quote was matched word for word to the source page.
Who may use fluoroscopy equipment and what training the rules ask for.
Fluoroscopy may be performed by ARRT-certified state license holders, by people performing fluoroscopy on January 1, 2020 who meet the exception's conditions, and under limited NRS 653.620 exceptions. Exemptions for physicians, PAs and NPs are unconfirmed.
License holders need ARRT certification to perform fluoroscopy. A grandfather clause covers people performing fluoroscopy on January 1, 2020. No required training hours, continuing education, or physician fluoroscopy training rule was found.
Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.
Draft (initial draft I and LCB draft P); adoption not confirmed
Would require monitoring when protective clothing or devices are worn (amending NAC 459.339 and 459.558), require registrants to supply monitoring to people who must wear protective clothing, restate who may perform fluoroscopy, and raise machine fees.
Second revised draft (RP2); adoption not confirmed
Amends machine registration (NAC 459.150-459.154) and NAC 459.554 (documenting protocols), and adds a requirement that CT systems used for CT fluoroscopy have policies and training to reduce staff exposure.
Informational statement; adoption not confirmed
Concerns dental lead aprons under NAC 459.554.
Revised draft; adoption not confirmed
Updates the radioactive-materials rules for NRC compatibility.
Questions the research could not settle. If you know the answer, tell us.
ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.
Found something wrong or missing? Tell ORSIF.
Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.