Is Maine an NRC Agreement State?
Yes. Maine is not among the non-Agreement States on the NRC list, and the NRC's July 10, 2025 periodic meeting summary on the Maine Agreement State Program is consistent with this.
What Maine's rules say about ALARA (as low as reasonably achievable), dose limits in millisieverts (mSv), dosimeters, aprons and training for the people who work in fluoroscopy labs.
Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made
ORSIF's research identified the Maine CDC Radiation Control Program, Department of Health and Human Services (DHHS) as the agency that regulates X-ray and fluoroscopy equipment in Maine. Maine is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.
Maine (an Agreement State) regulates X-ray through the Maine CDC Radiation Control Program under 10-144 CMR ch. 220. The occupational ALARA duty is in the shared Part D, not the X-ray-specific Part F, which mentions ALARA only in its quality assurance (QA) appendix. Dose limits follow the NRC model: 50 mSv whole body, 150 mSv lens (the International Commission on Radiological Protection (ICRP)'s lower limit has not been adopted), 500 mSv skin and extremities, and 5 mSv to the embryo/fetus. Fluoroscopy staff must be protected by aprons or whole-body barriers of at least 0.25 mm Pb, and aprons are tested semi-annually. The rules are silent on engineered apron alternatives, thyroid shields and eyewear. Physicians and supervised licensed radiographers may perform fluoroscopy, and credentialed CV technologists may do limited tasks; limited radiographers may not.
Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.
Which rules apply, and whether ALARA is among them.
Yes. Maine is not among the non-Agreement States on the NRC list, and the NRC's July 10, 2025 periodic meeting summary on the Maine Agreement State Program is consistent with this.
All rules are in 10-144 CMR ch. 220 (Radiation Protection Rule). Part D (Standards for Protection Against Radiation, October 23, 2022) covers licensees and registrants. Part F (X-Rays in the Healing Arts, October 23, 2022) covers medical X-ray, with §F.6 specific to fluoroscopy. Part A holds the definitions. The chapter was last amended October 23, 2022 (filing 2022-210).
Part D establishes standards for protection against ionizing radiation resulting from activities conducted pursuant to licenses or registrations issued by the Agency.This quote was matched word for word to the source page.
Yes. Part D requires every licensee or registrant (which includes X-ray machine users) to use procedures and engineering controls to keep occupational doses ALARA. Part F §F.3.A(1)(j) also makes X-ray personnel subject to D.1201, D.2104 and D.1502.
Where ALARA lives in Maine: Only in a rule shared with radioactive materials. The binding occupational ALARA duty is in Part D §1101.B, the Standards for Protection Against Radiation part shared by radioactive-materials licensees and X-ray registrants. Part F mentions ALARA only in Appendix G, as the stated basis for the QA program, and has a general duty to minimize personnel exposure (§F.3.A(1)(i)); neither is a separate occupational-dose ALARA requirement. This research's own reading, not stated in the rules, is that an NRC-driven change to Part D would affect the X-ray ALARA duty unless the State carves it out. (Part D §1101.B; Part F §F.3.A(1)(i) and Appendix G §I.C; 22 M.R.S. §674(4)(B)-(C))
The licensee or registrant shall use, to the extent practical, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are as low as is reasonably achievable (ALARA).This quote was matched word for word to the source page.
The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.
TEDE of 0.05 Sv (5 rem) = 50 mSv/yr, or 0.5 Sv to any organ other than the lens, whichever is more limiting. Minors are limited to 10% of the adult limits.
0.15 Sv (15 rem) = 150 mSv/yr. Maine has not adopted a lower lens limit such as the ICRP's 20 mSv.
(a) A lens dose equivalent of 0.15 Sv (15 rem), and (b) A shallow dose equivalent of 0.5 Sv (50 rem) to the skin of the whole body or to the skin of any extremity.This quote was matched word for word to the source page.
0.5 Sv (50 rem) = 500 mSv/yr shallow dose equivalent to the skin or any extremity.
(a) A lens dose equivalent of 0.15 Sv (15 rem), and (b) A shallow dose equivalent of 0.5 Sv (50 rem) to the skin of the whole body or to the skin of any extremity.This quote was matched word for word to the source page.
5 mSv (0.5 rem) to the embryo/fetus of a declared pregnant woman over the whole pregnancy. D.1208.D states the allowance remaining after declaration as "5mSv (0.05 rem)"; the units do not match, which looks like a typo in the Maine text.
When a worker must wear a dosimeter, and where.
Individual dosimeters must be supplied and used for: adults likely to exceed 10% of the D.1201.A limits in a year; minors likely to exceed 1 mSv deep dose, 1.5 mSv lens dose, or 5 mSv skin/extremity dose; declared pregnant women likely to exceed 1 mSv (0.1 rem) during the pregnancy; and anyone entering a high or very high radiation area. Part F §F.3.A(1)(j) applies this to X-ray personnel.
Adults likely to receive, in one year from sources external to the body, a dose in excess of 10 percent of the limits in D.1201.AThis quote was matched word for word to the source page.
When an apron is worn, at least one dosimeter must be worn at the collar, outside the apron. If more than one device is used, each dose must be identified with where it was worn, and the whole-body dose is based on the maximum dose attributed to the most critical organ. No formal two-badge method and no named effective-dose method (NCRP 122, Webster) is specified. Part D §1201.C allows effective dose equivalent only by a dosimetry method approved by the NRC.
When an apron is worn, the monitoring device shall be worn at the collar outside of the apron.This quote was matched word for word to the source page.
Protective apparel, how it is checked, and whether other systems are addressed.
Staff must be protected from scatter by protective aprons or whole-body protective barriers of at least 0.25 mm lead equivalent, and anyone who could be struck by the useful beam needs at least 0.5 mm. Facilities must keep enough leaded aprons and gloves. For fluoroscopy, under-table scatter must be attenuated by at least 0.25 mm Pb. For above-table scatter, staff must stand at least 120 cm from the beam center, or the scatter must pass through at least 0.25 mm Pb (drapes, Bucky-slot cover, curtains) in addition to the apron. Thyroid shields and protective eyewear are not addressed.
The x-ray operator, other staff, ancillary personnel and other persons required for the medical procedure shall be protected from the direct scatter radiation by protective aprons or whole body protective barriers of not less than 0.25 millimeter lead equivalent.This quote was matched word for word to the source page.
Yes, semi-annually. Under the Appendix G QA program, aprons, gloves and drapes are tested semi-annually. The method is not specified, and facilities may change tests or frequencies if they show image quality will still be assured.
Each facility shall conduct the following tests, at the frequency specified, and maintain records of the data.This quote was matched word for word to the source page.
Not specifically addressed; engineered apron-replacement systems are not mentioned. §F.3.A(1)(e)(ii) allows whole-body protective barriers as an alternative to aprons. §F.6.I(3) allows Agency exceptions where a sterile field prevents normal barriers. §F.3.D(4) allows exemptions with a qualified expert's written justification. No Maine bill or rule on this topic was found.
Exemptions to the requirements of Part F may be granted, provided written justification is submitted by a qualified expert.This quote was matched word for word to the source page.
Who may use fluoroscopy equipment and what training the rules ask for.
Physicians and other licensed practitioners may operate fluoroscopy, as may licensed radiographers under a licensed practitioner's supervision. Credentialed cardiovascular technologists may do certain table-side fluoroscopy tasks under a physician's direct supervision in cath and EP labs. Residents and students are exempt while supervised. Limited radiographers and limited-license trainees may not perform fluoroscopy. Whether PAs and NPs may operate is unclear.
Limited radiographers may not perform cardiovascular-interventional radiography, cardiac-interventional radiography, vascular interventional radiography, mammography, computed tomography, bone densitometry, fluoroscopy or administration of radiographic contrast.This quote was matched word for word to the source page.
There is no separate fluoroscopy permit and no fluoroscopy-specific training hours were found. Radiographers need a board-approved course and exam, or American Registry of Radiologic Technologists (ARRT) certification and current registration, plus continuing education at each two-year renewal (current ARRT registration in continuing education (CE) compliance or 24 CE hours, among other options). Cardiovascular technologists must hold the credentials named in the statute. For physicians, Part F requires only that operators be adequately instructed and competent.
Either have successfully completed a course of study in radiologic technology and an examination that is approved by the board or possess valid certification and current registration from the American Registry of Radiologic TechnologistsThis quote was matched word for word to the source page.
Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.
Enacted (2025)
Created a chiropractic radiographer exemption and amended the cardiovascular technologist exemption in 32 M.R.S. §9854(3).
Draft; scheduled to be adopted in early 2026; adoption not confirmed
Overdue or NRC-commented compatibility packages are in draft form and in the State's process. The Secretary of State still lists Parts D and F at October 23, 2022.
Enacted; effective January 1, 2027
Updates "physician associates" wording in 32 M.R.S. §9855(4).
Enacted (2025)
Amended the dental exemption.
Questions the research could not settle. If you know the answer, tell us.
ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.
Found something wrong or missing? Tell ORSIF.
Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.