Is South Carolina an NRC Agreement State?
Yes. South Carolina is an NRC Agreement State. Its radioactive-materials rule is R.61-63 (Title A).
Rule text and source
- Rule
- NRC list of Agreement States, updated October 29, 2026
- Source
- nrc.gov
What South Carolina's rules say about ALARA (as low as reasonably achievable), dose limits in millisieverts (mSv), dosimeters, aprons and training for the people who work in fluoroscopy labs.
Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made
ORSIF's research identified the SC Department of Environmental Services (SCDES), Bureau of Land & Waste Management, Radiation Protection Program, Division of Electronic Products as the agency that regulates X-ray and fluoroscopy equipment in South Carolina. South Carolina is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.
South Carolina regulates X-rays under a separate rule, R.61-64 (Title B), administered by SCDES (formerly DHEC). Its Part III requires registrants to keep doses ALARA, while radioactive-materials licensees follow R.61-63 (Title A). Dose limits are the standard US values, including a 150 mSv lens limit. All fluoroscopy personnel must be monitored, with badges at the collar outside the apron and formulas set for one-badge and two-badge dose estimates. Staff must be protected by aprons or whole-body barriers of at least 0.25 mm lead equivalent, and aprons and gloves must be inspected annually. Engineered systems that replace aprons are not addressed by name. Only licensed practitioners or SCRQSA-certified technologists may operate X-ray equipment. PAs, NPs and CRNAs need an SCRQSA fluoroscopy certificate.
Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.
Which rules apply, and whether ALARA is among them.
Yes. South Carolina is an NRC Agreement State. Its radioactive-materials rule is R.61-63 (Title A).
S.C. Code Ann. Regs. 61-64, X-Rays (Title B). Part III covers Standards for Protection Against Radiation (RHB 3.1-3.30). Part IV covers Use of X-Rays in the Health Professions, including RHB 4.2 general safety and RHB 4.9 fluoroscopic systems. Radioactive-materials licensees follow the separate R.61-63 Part III.
PART III - STANDARDS FOR PROTECTION AGAINST RADIATIONThis quote was matched word for word to the source page.
Yes. X-ray registrants must use procedures and engineering controls to keep occupational and public doses ALARA. They also need a written radiation protection program, a Radiation Safety Officer and investigative limits.
Where ALARA lives in South Carolina: In X-ray-specific rules. The registrant ALARA duty is in R.61-64 (Title B) RHB 3.3.2. Licensees have a separately worded duty in R.61-63 RHA 3.4.2. RHB 3.5 applies Title A dose-limit rules to registrants that are also licensees. In this research's reading, an NRC compatibility change would directly affect R.61-63, while changing R.61-64 would require a separate SCDES rulemaking. (R.61-64 RHB 3.3.2 and RHB 3.5; R.61-63 RHA 3.1 and RHA 3.4.2)
procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are as low as is reasonably achievable (ALARA).This quote was matched word for word to the source page.
The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.
5 rem (0.05 Sv), or 50 mSv, TEDE per year.
15 rem (0.15 Sv), or 150 mSv. South Carolina has not adopted the International Commission on Radiological Protection (ICRP) 20 mSv lens limit.
3.4.1.2.1 An eye dose equivalent of 15 rem (0.15 Sv), and 3.4.1.2.2 A shallow dose equivalent of 50 rem (0.5 Sv) to the skin or to any extremity.This quote was matched word for word to the source page.
Shallow dose of 50 rem (0.5 Sv), or 500 mSv, to the skin or any extremity.
3.4.1.2.1 An eye dose equivalent of 15 rem (0.15 Sv), and 3.4.1.2.2 A shallow dose equivalent of 50 rem (0.5 Sv) to the skin or to any extremity.This quote was matched word for word to the source page.
0.5 rem (5 mSv) to the embryo/fetus of a declared pregnant woman over the whole pregnancy. An extra badge worn under the apron is available on request and must be read at least monthly.
When a worker must wear a dosimeter, and where.
Individual monitoring is required for anyone likely to exceed 10% of the applicable limits. All personnel working with medical fluoroscopic equipment must be monitored regardless of expected dose. Dosimeters are read at least quarterly, returned within 45 days, and processed by a National Voluntary Laboratory Accreditation Program (NVLAP)-accredited processor.
3.12.4.1.4 Personnel working with medical fluoroscopic equipment.This quote was matched word for word to the source page.
A single badge is worn at the collar outside the apron. With one collar badge, effective dose = deep dose × 0.3. With two badges, effective dose = 1.5 × waist badge under the apron + 0.04 × neck badge outside the apron. The radiation safety officer (RSO) may choose effective dose as the record, subject to semi-annual observation visits, and SCDES may revoke its use. Guidance B2 says the outside badge is the permanent record when two badges are worn.
the reported deep dose equivalent value multiplied by 0.3 shall be the effective dose for external radiationThis quote was matched word for word to the source page.
Protective apparel, how it is checked, and whether other systems are addressed.
Staff must be protected from scatter by aprons or whole-body barriers of at least 0.25 mm lead equivalent. Body parts in the useful beam need at least 0.5 mm lead equivalent. Facilities must have enough aprons and gloves. Fluoroscopy also requires at least 0.25 mm lead equivalent drapes or curtains against scatter. Thyroid shields and eyewear for staff are not addressed.
protected from the direct scattered radiation by protective aprons or whole body protective barriers of not less than 0.25 mm lead equivalent material.This quote was matched word for word to the source page.
Aprons and gloves must be checked at least annually for cracks and holes. Checks are documented and records kept for 2 years or until the next inspection, whichever is later. The method is not specified.
Protective aprons and gloves shall be checked at least annually for cracks and holes that could compromise the radiation protection it provides.This quote was matched word for word to the source page.
Engineered systems are not addressed by name. RHB 4.2.9.2 accepts whole-body protective barriers of at least 0.25 mm lead equivalent as an alternative to aprons, and RHB 4.9.13.7 allows a protected area instead of an apron for vertical fluoroscopic systems. Whether this covers engineered systems is this research's reading, not the agency's.
Operators shall remain in a protected area during exposures, or shall be protected by aprons of not less than 0.25 millimeter lead equivalent material.This quote was matched word for word to the source page.
Who may use fluoroscopy equipment and what training the rules ask for.
Only licensed practitioners or SCRQSA-certified technologists working under a licensed practitioner's direction may operate X-ray equipment. Only licensed practitioners may use fluoroscopy to position a patient. Others may use fluoroscopy only with a licensed practitioner physically in the room. PAs, NPs and CRNAs need the SCRQSA Limited Practice Radiographer, Fluoroscopy certificate, and the presence rule appears to apply to them (this research's reading). Students and residents may operate under supervision without a certificate.
It shall be unlawful for a person other than a licensed practitioner to use fluoroscopy when the licensed practitioner is not physically present in the roomThis quote was matched word for word to the source page.
Technologists need an SCRQSA certificate (ARRT-certified technologists qualify without an exam) and 24 hours of continuing education (CE) every 2 years. PAs, NPs and CRNAs need 40 hours of didactic and 40 hours of clinical fluoroscopy training, a letter from the supervising radiologist, a passing American Registry of Radiologic Technologists (ARRT) Fluoroscopy exam (75%) and 8 hours of CE every 2 years; this has applied since Sept. 1, 2023. Registrants must document facility-specific training. No physician fluoroscopy training requirement was found.
you must complete 40 hours of didactic training in fluoroscopy, and an additional 40 hours of clinical training.This quote was matched word for word to the source page.
Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.
Amended July 24, 2026; substance not checked
ALARA is still in RHA 3.4.2 of the current PDF.
Proposed Feb. 27, 2026; exempt from General Assembly review; hearing canceled; listed in SCDES PDF history as April 24, 2026 (Vol. 50, Issue 4)
Incorporates FDA MQSA amendments; changes Parts V and X only, not occupational protections.
Amended May 23, 2025; document not read
Appears to be the DHEC-to-DES name change.
Notice of Drafting published (Jul 24, 2026)
Further name-change package for R.61-63; substance not checked.
Enacted; effective May 15, 2026
Substituted the new agency name in S.C. Code §§44-74-50 and -60.
Unverified; seen only in search results
Concerns pediatric patient imaging.
Questions the research could not settle. If you know the answer, tell us.
ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.
Found something wrong or missing? Tell ORSIF.
Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.