The Evidence
Resources
Clinician AssessmentGet Your Risk Score FAQs Admin ToolkitMembers Economic Impact Research ArticlesMembers SIRP 2025 WebinarMembers Videos
Guidelines
What is ALARA+? US Guidelines International Guidelines News Is Not Here About Contact Donate
Join Free

Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Oklahoma State Department of Health (OSDH), Consumer Health Service (X-Ray program) for diagnostic X-ray including fluoroscopy; Department of Environmental Quality (DEQ), Land Protection Division, Radiation Management Section for radioactive materials and therapeutic, industrial and analytical X-ray as the agency that regulates X-ray and fluoroscopy equipment in Oklahoma. Oklahoma is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Oklahoma splits radiation regulation between two agencies. OSDH regulates diagnostic X-ray, including fluoroscopy, under OAC 310:281. DEQ regulates radioactive materials and therapeutic and industrial X-ray under OAC 252:410, which excludes OSDH-regulated diagnostic X-ray facilities. Chapter 281's only ALARA sentence covers unrestricted areas, not worker doses; DEQ's adoption of 10 CFR 20.1101 does not apply to fluoroscopy. Worker dose limits are the standard US values: 50 mSv whole body, 150 mSv lens, 500 mSv skin and extremities, and 5 mSv embryo/fetus. Lead aprons or whole-body barriers (0.25 or 0.5 mm lead equivalent) are required and must be checked annually. The rules do not address engineered alternatives to aprons. Oklahoma does not license radiologic technologists, and fluoroscopy must be used by or under the supervision of a licensed practitioner.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Oklahoma an NRC Agreement State?

Yes

Yes. Oklahoma is an NRC Agreement State. DEQ runs the program, and the DEQ rule states the agreement relationship.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; OAC 252:410-1-1(c)
Source
nrc.gov
oklahoma.gov
What it says
Any regulation by the State of Oklahoma of source material, byproduct material and special nuclear material in quantities not sufficient to form a critical mass is subject to agreement between the State and the U.S. Nuclear Regulatory Commission
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Oklahoma?

YesCheck the source

Fluoroscopy and diagnostic X-ray are covered by OAC Title 310, Chapter 281, "Diagnostic X-Ray Systems." Subchapter 9 is "Standards for Protection Against Radiation" and Subchapter 11 is "Use of X-Rays in the Healing Arts and Veterinary Medicine"; fluoroscopy controls are in 310:281-11-7. The latest amendment shown is 38 Ok Reg 1954, effective 9-11-2021. DEQ's OAC 252:410 Subchapter 20 adopts parts of 10 CFR 20 by reference for radioactive materials and non-diagnostic X-ray only.

Rule text and source
Rule
OAC 310:281-1-1; 310:281 Subch. 9 and 11; OAC 252:410-20-1
Source
oklahoma.gov

Why this matters, in ORSIF's FAQs

Does Oklahoma require X-ray users to keep doses as low as reasonably achievable (ALARA)?

In partLess certain

Only partly. Chapter 281's single ALARA sentence covers exposures to unrestricted areas. No wording was found requiring occupational doses to be kept ALARA, and no radiation protection program requirement was found. The closest occupational provision, 11-7(b)(3), requires the fluoroscopic field to be reduced "to the absolute minimum required" when sterile fields rule out drapes or barriers.

Where ALARA lives in Oklahoma: In X-ray-specific rules. The fluoroscopy ALARA sentence is in OSDH's own Chapter 281, a separate rule from a separate agency. DEQ's 252:410-20-1 adopts 10 CFR 20.1101 but applies only to sources under DEQ jurisdiction, and 252:410-1-1(b) excludes OSDH diagnostic X-ray facilities. An NRC Part 20 compatibility change would flow most directly into the DEQ rule, not Chapter 281. Hospitals that also hold a DEQ radioactive-materials license are under both rules. (OAC 252:410-20-1(a), (c)(2); 252:410-1-1(b); OAC 310:281-9-1(b))

Rule text and source
Rule
OAC 310:281-9-1(b)
Source
oklahoma.gov
What it says
In addition to complying with the requirements set forth in this subchapter, every reasonable effort shall be made to maintain radiation exposures to unrestricted areas to as low as is reasonably achievable.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual eye-lens dose limit in Oklahoma?

Yes

15 rem (150 mSv) per year. No lower lens limit, such as the International Commission on Radiological Protection (ICRP)'s 20 mSv, has been adopted.

Rule text and source
Rule
OAC 310:281-9-2(b)
Source
oklahoma.gov
What it says
(3) Lens dose equivalent (LDE) is 15 Rems; and (4) Shallow dose equivalent (SDE) to the skin or any extremity is 50 Rems.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Oklahoma?

Yes

50 rem (500 mSv) per year to the skin or any extremity.

Rule text and source
Rule
OAC 310:281-9-2(b)
Source
oklahoma.gov
What it says
(3) Lens dose equivalent (LDE) is 15 Rems; and (4) Shallow dose equivalent (SDE) to the skin or any extremity is 50 Rems.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Oklahoma?

Yes

0.5 rem (5 mSv) to the embryo/fetus of a declared pregnant woman over the whole pregnancy. The rule also adopts National Council on Radiation Protection and Measurements (NCRP) 91 guidance of no more than 0.05 rem (0.5 mSv) per month.

Rule text and source
Rule
OAC 310:281-9-40
Source
oklahoma.gov
What it says
does not exceed 0.5 rem (5 mSv).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Oklahoma wear a dosimeter?

Yes

No percentage threshold by default. Dosimeters must be issued to everyone who enters a controlled or high radiation area and to everyone who uses or operates any source of radiation. OSDH may grant a written exemption if no one is likely to exceed 25% of the annual limits (5% for people under 18). For fluoroscopy where sterile fields prevent drapes or barriers, everyone in the room except the patient must have monitoring devices. Dental-only operators are exempt.

Rule text and source
Rule
OAC 310:281-9-12(a)-(b); 310:281-11-7(b)(2)
Source
oklahoma.gov
What it says
Each permittee shall supply and require the use of appropriate personnel monitoring equipment to: (1) each individual who enters a controlled radiation area; (2) each individual who enters a high radiation area; and (3) each individual who uses or operates any source of radiation.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Oklahoma when a protective apron is worn?

Yes

With an apron, the whole-body badge is worn at the unshielded location likely to get the highest dose, typically the collar. The lens badge goes at the collar or closer to the eye, outside the apron; the embryo/fetus badge at the waist under the apron; the extremity badge on the extremity likely to get the highest dose. Wear periods are no more than three months. Effective dose equivalent may be assigned by one of three methods: the collar badge deep dose equivalent; the collar badge × 0.3; or 1.5 × the waist badge under the apron + 0.04 × the collar badge outside it. The factors match NCRP 122, but the rule does not name it. 11-4(d)(1) requires the collar badge reading to be recorded as whole-body dose, which may conflict with 9-3(c).

Rule text and source
Rule
OAC 310:281-9-12(d); 310:281-9-3(c); 310:281-11-4(d)(1)
Source
oklahoma.gov
What it says
the EDE for external radiation is assigned the value of the sum of the DDE reported for the personal monitoring device located at the waist under the protective apron multiplied by 1.5 and the DDE reported for the personal monitoring device located at the neck (collar) outside the protective apron multiplied by 0.04.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Oklahoma fluoroscopy rooms wear protective aprons or other apparel?

Yes

In general radiography, staff must be protected from scatter by aprons or whole-body protective barriers of at least 0.25 mm lead equivalent; anyone whose body may be struck by the direct beam needs 0.5 mm lead-equivalent apron, gloves or shielding. In fluoroscopy, the setup must keep scatter to the body (except head, neck and extremities) behind at least 0.25 mm lead equivalent, with drapes, curtains or viewing shields counting in addition to any apron. Where sterile fields prevent drapes or barriers, everyone except the patient must wear 0.5 mm lead-equivalent aprons. Thyroid shields and protective eyewear are not addressed.

Rule text and source
Rule
OAC 310:281-11-6(c); 310:281-11-7(a)-(b)
Source
oklahoma.gov
What it says
All persons, except the patient, in the room where fluoroscopy is performed, shall wear protective aprons which provide a shielding equivalent of 0.5 millimeter of lead.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Oklahoma require protective aprons to be inspected?

Yes

Yes, annually. Aprons, gloves and shields must be checked for defects and the check recorded; defective items must be replaced or removed from service until repaired. The inspection method is not specified.

Rule text and source
Rule
OAC 310:281-11-4(d)(2)
Source
oklahoma.gov
What it says
Protective equipment including aprons, gloves, and shields shall be checked annually for defects, such as holes, cracks, and tears to assure reliability and integrity. A record of this test shall be made and maintained for inspection by the Department.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Oklahoma address engineered protection systems used in place of aprons?

Not foundLess certain

Not addressed. Chapter 281 does not mention engineered radiation protection systems used in place of aprons. 11-6(c)(2) accepts "whole body protective barriers" as an alternative to aprons for scatter in general radiography. 11-7 treats drapes, curtains and shields as additions to any apron and requires 0.5 mm aprons when barriers can't be used. A 2025 PMC study lists Oklahoma among 15 states that specifically require lead aprons.

Rule text and source
Rule
OAC 310:281-11-6(c)(2); 310:281-11-7(a)
Source
oklahoma.gov
What it says
Staff and ancillary personnel shall be protected from primary scatter (once-scattered) radiation by protective aprons or whole body protective barriers of not less than 0.25 millimeter lead equivalent material.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Oklahoma?

In partLess certain

All use must be by or under the supervision of a person licensed under Oklahoma law to practice the relevant healing art. The rules do not list operator categories or define fluoroscopy supervision levels. Oklahoma does not license radiologic technologists (per secondary sources). Radiologist assistants, licensed by the Board of Medical Licensure and Supervision, may operate a fluoroscopic unit under general supervision of the supervising radiologist (rule dated Eff. 6-25-09, possibly out of date).

Rule text and source
Rule
OAC 310:281-11-1(a); OAC 435:60-7-3(a)(16)
Source
oklahoma.gov
What it says
All usage of such systems under this Subchapter shall be made by or under the supervision of an individual licensed in accordance with Oklahoma law to practice the healing art or veterinary medicine in which a diagnostic x-ray system is used.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Oklahoma require to operate fluoroscopy equipment?

In partLess certain

Operators need only be instructed in, and able to show competence with, the permittee's operating and safety procedures, and must be given written procedures. No state fluoroscopy permit, American Registry of Radiologic Technologists (ARRT) requirement, training hours, continuing education or physician fluoroscopy training requirement was found. CT has a specific-training requirement; fluoroscopy has none. Radiologist assistants must be ARRT-registered R.R.A.s who completed an ARRT-accredited program.

Rule text and source
Rule
OAC 310:281-11-4(f); OAC 435:60-3-2
Source
oklahoma.gov
What it says
Individuals who operate diagnostic x-ray systems shall be instructed in and be able to demonstrate competence with the permittee's operating and safety procedures.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Proposed ruleDEQ OAC 252:410, OAR Docket #25-651

    Proposed permanent rule published 8/15/2025, comments closed 9/25/2025; not on the 11/6/2025 or 1/21/2026 EQB agendas reviewed; adoption status unconfirmed (Aug 15, 2025)

    Would update the 10 CFR incorporation date to January 1, 2025, to maintain compatibility with federal regulations. Affects DEQ licensees, not OSDH fluoroscopy rules.

    Source: oklahoma.gov

  • BillSB 439 (2025, Sen. Bergstrom)

    Introduced 1/8/2025; final status unconfirmed (Jan 8, 2025)

    Relates to diagnostic X-ray systems and requires the Board of Dentistry to enforce certain laws; appears aimed at dental X-ray.

    Source: www3.oklegislature.gov

  • OtherOSDH online X-ray permitting portal

    Implemented (Apr 22, 2026)

    OSDH moved X-ray permitting to an online portal.

2 other items the research logged (radiation therapy, industrial machines, fees and other subjects)
  • Adopted ruleOSDH Chapter 281 amendment (38 Ok Reg 1954)

    Adopted 1-25-2021, approved by HJR 1046, effective 9-11-2021; no 2025 or 2026 proposal to amend Chapter 281 found (Sep 11, 2021)

    Changed suggested exposure limits to mandatory limits and exempted dental cone beam CT and non-diagnostic CT systems from survey requirements.

    Source: oklahoma.gov

  • OtherRadiation Management Advisory Council sunset

    Sunset per a DEQ advisory-councils page seen in search results (Jul 1, 2026)

    The DEQ Radiation Management Advisory Council was sunset.

Also worth knowing

  • 310:281-9-2(c) still lets a permittee allow a whole-body dose greater than the annual standard, provided it stays under 3 rem (30 mSv) per calendar quarter and dose history is documented. This is pre-1994-style wording that sits awkwardly with the 5 rem total effective dose equivalent (TEDE) limit.
  • 11-4(d)(1) requires the collar badge to be recorded as whole-body dose, which may conflict with the reduced effective-dose methods in 9-3(c).
  • Incidents must be reported immediately at 25 rem whole body, 150 rem skin or 375 rem extremities, and within 24 hours at 5, 30 or 75 rem (9-31).
  • Dosimetry must be processed by a National Voluntary Laboratory Accreditation Program (NVLAP)-accredited processor (9-12(c)).
  • People may not be used routinely to hold patients or film, and holders must be protected (11-6(e)).
  • 63 O.S. § 1-1505 requires OSDH X-ray rules to be "consistent with nationally recognized standards."
  • No Oklahoma bill or rule on engineered protection systems comparable to Arizona SB 1121 or the pending Illinois rule was found.
  • Minors are limited to 10% of the adult dose limits (9-5).

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Confirm on the Oklahoma Office of Administrative Rules site (rules.ok.gov) that no amendment to Chapter 281 after 9-11-2021 exists; OSDH's posted PDFs were used instead of the official portal.
  • Final status of SB 439 (2025); check oklegislature.gov BillInfo for the 2025-2026 sessions.
  • Adoption status and effective date of DEQ Docket #25-651; check the DEQ Land Protection Division proposed-rules page and later Oklahoma Register issues.
  • Whether OSDH reads any Chapter 281 provision, or the 63 O.S. "nationally recognized standards" clause, as requiring occupational ALARA; ask OSDH Consumer Health Service, (405) 426-8250.
  • Whether physician assistants, nurse practitioners or unlicensed technologists may run fluoroscopy, and under what supervision, under Medical, Osteopathic and Nursing board scope-of-practice rules, which were not reviewed.
  • Whether OSDH would accept engineered whole-body shielding in place of aprons under 11-6(c)(2) and 11-7; no guidance found.
  • Confirm on oklegislature.gov that the radiologic technologist licensure bills (SB 1329 in 2018; HB 2041 committee substitute in 2019-20) were not enacted.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 1 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 5 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ICRP
International Commission on Radiological Protection
NCRP
National Council on Radiation Protection and Measurements
TEDE
Total effective dose equivalent
ARRT
American Registry of Radiologic Technologists
NVLAP
National Voluntary Laboratory Accreditation Program
All 15 sources the research read

Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.