Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Radiation Safety Section, Technical Services Division, MIOSHA (Michigan Occupational Safety and Health Administration), Department of Labor and Economic Opportunity (LEO) as the agency that regulates X-ray and fluoroscopy equipment in Michigan. Michigan is not a U.S. Nuclear Regulatory Commission (NRC) Agreement State, so the NRC regulates radioactive materials there directly. The state still regulates X-ray machines.

Michigan's X-ray rules define ALARA but impose no operative ALARA requirement. Those rules cover only radiation machines, and Michigan is not an NRC Agreement State. Occupational dose limits match the NRC's, including a 150 mSv lens limit. Everyone in a fluoroscopy room except the patient must wear an apron of at least 0.5 mm lead equivalence. The rules are silent on engineered shielding, though secondary sources report a state certification of one engineered shielding system. Since March 13, 2024, non-physician operators must hold a recognized credential. There is no state license, and conditional status ends March 13, 2027.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Michigan an NRC Agreement State?

No

No. Michigan is not an NRC Agreement State, so the NRC regulates radioactive materials there directly.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026
Source
nrc.gov

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Michigan?

Yes

Michigan Administrative Code R 333.5001-R 333.5721, "Ionizing Radiation Rules Governing the Use of Radiation Machines." Most rules took effect 5/25/2016. R 333.5065 was amended in 2023 and Part 5 was added effective 3/13/2024. Part 3 contains the general protection standards, Part 7 covers medical X-ray (fluoroscopy at R 333.5337,.5347 and.5348) and Part 5 covers operator qualifications. The governing statute is MCL 333.13501 et seq.

Rule text and source
Rule
R 333.5051(1); R 333.5052
Source
ars.apps.lara.state.mi.us
What it says
This part applies to radiation machine registrants of the department.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Michigan require X-ray users to keep doses as low as reasonably achievable (ALARA)?

NoLess certain

ALARA is defined in R 333.5002(5), but no operative requirement to keep doses ALARA was found. The closest provisions are R 333.5093(1)(a) (instruction in precautions to minimize exposure) and R 333.5348(2) (only necessary people in the fluoroscopy room).

Where ALARA lives in Michigan: No ALARA requirement found for X-ray users. The ALARA definition appears only in the radiation-machine rules (R 333), which since 2016 apply only to machines, and no rule imposes it. The NRC regulates radioactive materials in Michigan directly. The status of the older R 325.5001 et seq. rules is unconfirmed. (R 333.5002(5); LEO notice "New Radiation Machine Rules Now Effective" (5/25/2016))

Rule text and source
Rule
R 333.5002(5)
Source
ars.apps.lara.state.mi.us
What it says
"As low as reasonably achievable" (ALARA) means making every reasonable effort to maintain exposures to radiation as far below the dose limits in these rules as is practical
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual eye-lens dose limit in Michigan?

Yes

0.15 Sv (15 rem), or 150 mSv per year. No lower limit has been adopted.

Rule text and source
Rule
R 333.5057(1)
Source
ars.apps.lara.state.mi.us
What it says
(i) A lens dose equivalent of 0.15 sieverts (15 rem). (ii) A shallow dose equivalent of 0.5 sievert (50 rem)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Michigan?

Yes

0.5 Sv (50 rem), or 500 mSv per year, shallow dose equivalent to the skin of the whole body or the extremities.

Rule text and source
Rule
R 333.5057(1)
Source
ars.apps.lara.state.mi.us
What it says
(i) A lens dose equivalent of 0.15 sieverts (15 rem). (ii) A shallow dose equivalent of 0.5 sievert (50 rem)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Michigan wear a dosimeter?

Yes

The general rule requires a dosimeter for adults likely to exceed 10% of a limit, minors above set lower levels, declared pregnant women likely to exceed 1 mSv, and anyone entering a high radiation area. For diagnostic X-ray, every occupationally exposed person must be monitored. Under policy MIOSHA-RSS-118, only the operator of a mini C-arm needs a dosimeter.

Rule text and source
Rule
R 333.5064(a); R 333.5348(3); MIOSHA-RSS-118
Source
michigan.gov
What it says
Personnel monitoring shall be performed in controlled areas for each individual occupationally exposed to ionizing radiation from diagnostic x-ray equipment.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Michigan when a protective apron is worn?

Yes

With an apron, the whole-body badge goes at the unshielded location of highest exposure, typically the neck. The lens badge goes at the neck or nearer the eye, and the fetal badge at the waist under the apron. With one collar badge, the deep dose counts as the effective dose, or the deep dose may be multiplied by 0.3 if it exceeds 25% of the limit. With two badges, effective dose is 1.5 × waist + 0.04 × neck. The department may approve other methods. R 333.5348(5) conflicts by saying badges are normally worn on the chest or abdomen.

Rule text and source
Rule
R 333.5057(3)(b); R 333.5065; R 333.5348(5)
Source
ars.apps.lara.state.mi.us
What it says
multiplied by 1.5 and the deep dose equivalent reported for the individual monitoring device located at the neck outside the protective apron multiplied by 0.04
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Michigan fluoroscopy rooms wear protective aprons or other apparel?

Yes

Everyone in a fluoroscopy room except the patient must wear an apron of at least 0.5 mm lead equivalence. Fixed fluoroscopes need drapes or panels of at least 0.25 mm lead equivalence. Mobile-unit operators need a 0.5 mm apron unless 1.6 mm portable shielding is provided. No thyroid shield or eyewear requirement was found.

Rule text and source
Rule
R 333.5348(1); R 333.5337(6); R 333.5353(2)
Source
ars.apps.lara.state.mi.us
What it says
An individual present in a fluoroscopic room, except the patient, shall wear a protective apron of at least 0.5 millimeter lead equivalence.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Michigan require protective aprons to be inspected?

Not foundLess certain

not found

Rule text and source
Source
ars.apps.lara.state.mi.us
What it says
Unauthorized override of safety interlocks or other intentional misuse or non-use of required safety equipment shall be considered willful violation
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Michigan address engineered protection systems used in place of aprons?

UnclearCheck the source

The rules do not address engineered shielding systems, and R 333.5348(1) requires aprons for everyone present. R 333.5015 allows exemptions where there is no undue hazard. Secondary sources report that Michigan certified one engineered shielding system for use without aprons, but no primary state record was found. Separately, the statute exempts operators of handheld dental X-ray systems from aprons under certain conditions (MCL 333.13527).

Rule text and source
Rule
R 333.5348(1); R 333.5015; MCL 333.13527
Source
scholarlyworks.corewellhealth.org

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Michigan?

In partLess certain

Facilities may not employ non-exempt people to perform medical radiologic technology unless they meet Part 5 or have the department's written approval. Article 15 licensed practitioners acting within their scope of practice, including physicians, are exempt. Whether PAs, NPs and RNs are covered is unclear. Technologists work under general supervision and students need direct supervision. Violations are cited against the facility.

Rule text and source
Rule
R 333.5201(2); R 333.5209(1); R 333.5206(1)
Source
ars.apps.lara.state.mi.us
What it says
a registrant shall not employ an individual to perform medical radiologic technology who does not meet the requirements of this part
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Michigan require to operate fluoroscopy equipment?

Yes

There is no state license or fluoroscopy permit, and none is planned. Operators need a recognized credential, such as American Registry of Radiologic Technologists (ARRT) (R) or CAMRT, or for cardiac and interventional work ARRT CV, CI or VI or CCI RCIS. Temporary status lasts up to 3 years after an approved program. Conditional status based on a signed statement of assurance ends March 13, 2027. Limited radiographers need 40 hours of training plus 12 continuing education (CE) credits every 24 months, and their categories exclude fluoroscopy. No fluoroscopy-specific training requirement for physicians was found.

Rule text and source
Rule
R 333.5210; R 333.5211(e); R 333.5212; R 333.5213
Source
michigan.gov
What it says
No, a license is not required, and a licensing program is not anticipated.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Adopted rulePart 5 operator qualifications (R 333.5201-R 333.5213)

    Adopted; effective 3/13/2024 (Mar 13, 2024)

    Adds credential requirements for non-exempt operators.

  • Adopted ruleAmendment to R 333.5065

    Adopted 2023

    Amended dosimeter placement rule.

  • Proposed ruleDraft rule set 2026-25 LE

    Filed with JCAR in 2026 as a Draft Proposed Rule; hearing and adoption dates unconfirmed

    Would amend Part 5 (R 333.5203,.5205,.5207,.5209,.5210,.5211): add an explicit licensed-practitioner exemption, add nurse-practitioner wording to a definition, say bone densitometry includes non-osseous tissue, and fix March 13, 2027 as the end of conditional status. Known from search excerpts only.

    Source: council.legislature.mi.gov

1 other item the research logged (radiation therapy, industrial machines, fees and other subjects)
  • BillPublic Act 63 of 2025 (SB 136)

    Enacted; effective March 24, 2026

    Moves mammography standards into LEO rules, resets fees with CPI adjustment from October 1, 2026, and repeals the Radiation Advisory Board (MCL 333.13531).

    Source: legislature.mi.gov

Also worth knowing

  • The radiation program sits inside MIOSHA, Michigan's workplace-safety agency.
  • Part 4 (R 333.5091-.5101) covers instructions to workers, worker requests for inspection (R 333.5098) and employee protection (R 333.5101); only the section titles were seen.
  • Registrants may not require routine radiation staff to hold patients (R 333.5333(3)).
  • Only necessary people may be in the fluoroscopy room (R 333.5348(2)).
  • The mini C-arm dosimetry policy (RSS-118) relaxes badge requirements for assisting staff.
  • PA 63 of 2025 abolished the Radiation Advisory Board.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Do R 325.5001-R 325.5721 still apply to any radioactive material in Michigan, and do they contain an ALARA requirement?
  • Is ALARA imposed indirectly, for example through registration conditions, shielding-plan review or inspection guidance?
  • What form did that certification take, and who does it cover?
  • Do PAs, NPs and RNs fall under the R 333.5209(1) licensed-practitioner exemption, and what would draft 2026-25 LE change?
  • How does the department enforce the conflict between R 333.5348(5) (chest or abdomen badge) and R 333.5065(a) (collar badge)?
  • Are there 2025-26 bills on technologist licensure, aprons or shielding? A full legislative search was not run.
  • The 2016 notice, MCL 333.13527 and the 2026-25 LE draft were read only through search excerpts; their text needs verification.

Who regulates, and where to read the rules

Documents ORSIF has on file

Copies saved earlier. Rules change, so check the current text at the source.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

  • The rule itself. Open "Rule text and source" under any answer, or read the sources listed below.
  • The state. Radiation Safety Section. Program contacts in the CRCPD directory.
  • Your radiation safety officer. They know the federal, accreditation and facility requirements that apply at your site, which the state rules do not cover.

What may be missing here

  • 2 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 4 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ARRT
American Registry of Radiologic Technologists
CE
Continuing education
All 14 sources the research read