Search

186 results for “lead apron”, 52 in State rules.

Results

  1. State rules

    Indiana Radiation Safety Rules for Fluoroscopy Teams

    …pregnant workers. Staff in the room must be protected by aprons or whole-body protective barriers of at least 0.25 mm lead equivalent, but the rules say nothing specific about engineered radiation…

    orsif.org/guidelines/us/states/indiana

  2. State rules

    West Virginia Radiation Safety Rules for Fluoroscopy Teams

    …embryo/fetus, and all fluoroscopy workers must be badged. Aprons or whole-body barriers of at least 0.25 mm lead equivalent are required, but there is no apron inspection rule and the rules do not…

    orsif.org/guidelines/us/states/west-virginia

  3. State rules

    Hawaii Radiation Safety Rules for Fluoroscopy Teams

    …of a declared pregnant woman. Staff must be protected by aprons or whole-body barriers of at least 0.25 mm lead equivalent unless a qualified medical physicist authorizes otherwise, and the rules are…

    orsif.org/guidelines/us/states/hawaii

  4. State rules

    Georgia Radiation Safety Rules for Fluoroscopy Teams

    …mSv). Staff who must stay in the room must be protected by aprons "or whole body protective barriers" of at least 0.25 mm lead equivalent, dosimeters are worn outside the apron at the collar, and the…

    orsif.org/guidelines/us/states/georgia

  5. State rules

    Wyoming Radiation Safety Rules for Fluoroscopy Teams

    …achievable (ALARA). Wyoming rules do not require lead aprons, thyroid shields or protective eyewear, do not require apron inspection, say nothing about where to wear a badge with an apron, and do not…

    orsif.org/guidelines/us/states/wyoming

  6. State rules

    Maryland Radiation Safety Rules for Fluoroscopy Teams

    …(effective 15 September 2025) deleted the general 0.25 mm apron rule, leaving a fluoroscopy standard of 0.25 mm lead-equivalent shielding or 120 cm distance; aprons need no scheduled inspection, and…

    orsif.org/guidelines/us/states/maryland

  7. State rules

    District of Columbia Radiation Safety Rules for Fluoroscopy Teams

    …mSv/yr lens limit. Fluoroscopy staff must be protected by aprons or whole-body protective barriers of at least 0.25 mm lead equivalent, and the posted rules set no schedule for inspecting aprons for…

    orsif.org/guidelines/us/states/district-of-columbia

  8. State rules

    Pennsylvania Radiation Safety Rules for Fluoroscopy Teams

    …mSv per year with no lower state limit. Staff must wear aprons of at least 0.25 mm lead equivalent or use whole protective barriers, and the rules do not address engineered systems used instead of…

    orsif.org/guidelines/us/states/pennsylvania

  9. State rules

    North Carolina Radiation Safety Rules for Fluoroscopy Teams

    …Staff in the room must wear apparel of at least 0.25 mm lead equivalent or use whole-body protective equipment of the same rating, and the rules say where to wear the badge when such equipment…

    orsif.org/guidelines/us/states/north-carolina

  10. State rules

    Nevada Radiation Safety Rules for Fluoroscopy Teams

    …a limit, with the dosimeter worn at the collar outside the apron. Staff must use 0.25 mm lead-equivalent aprons or whole-body barriers, or keep their distance, but aprons do not have to be inspected…

    orsif.org/guidelines/us/states/nevada

  11. State rules

    New Mexico Radiation Safety Rules for Fluoroscopy Teams

    Staff must be protected by aprons or whole-body protective barriers of at least 0.25 mm lead equivalent, and any body part in the useful beam needs 0.5 mm. For fluoroscopy scatter, under-table scatter…

    orsif.org/guidelines/us/states/new-mexico

  12. State rules

    Alabama Radiation Safety Rules for Fluoroscopy Teams

    …lens, 500 mSv skin/extremities, and 5 mSv embryo/fetus. Aprons of at least 0.25 mm lead equivalent are required for all in the room except the patient, unless measurements indicate otherwise; the…

    orsif.org/guidelines/us/states/alabama

  13. State rules

    California Radiation Safety Rules for Fluoroscopy Teams

    …staff likely to be exposed to 5 mR/hr or more must wear aprons of at least 0.25 mm lead equivalent, drapes and panels may not substitute for them, and the rules are silent on thyroid shields, eyewear,…

    orsif.org/guidelines/us/states/california

  14. State rules

    Kentucky Radiation Safety Rules for Fluoroscopy Teams

    …in the fluoroscopy room except the patient must wear an apron of at least 0.25 mm lead equivalent; leaded drapes may be used only in addition to aprons, not instead of them, and periodic apron…

    orsif.org/guidelines/us/states/kentucky

  15. State rules

    Rhode Island Radiation Safety Rules for Fluoroscopy Teams

    …the fluoroscopy room except the patient must wear 0.25 mm lead-equivalent garments that are checked for integrity annually; the general X-ray rule also accepts "whole-body protective barriers" for…

    orsif.org/guidelines/us/states/rhode-island

  16. State rules

    Michigan Radiation Safety Rules for Fluoroscopy Teams

    …in a fluoroscopy room except the patient must wear an apron of at least 0.5 mm lead equivalence. The rules are silent on engineered shielding, though secondary sources report a state certification of…

    orsif.org/guidelines/us/states/michigan

  17. State rules

    Washington Radiation Safety Rules for Fluoroscopy Teams

    …fluoroscopy room must wear a collar dosimeter outside the apron and be shielded by aprons or whole-body barriers of at least 0.25 mm lead equivalent, but thyroid shields and eyewear are not required…

    orsif.org/guidelines/us/states/washington

  18. State rules

    Wisconsin Radiation Safety Rules for Fluoroscopy Teams

    …operators must wear a dosimeter, and the rule sets apron badge placement and dose formulas. Facilities must supply protective garments and X-ray them for defects every 2 years. The rules do not name…

    orsif.org/guidelines/us/states/wisconsin

  19. State rules

    Arizona Radiation Safety Rules for Fluoroscopy Teams

    Aprons of at least 0.25 mm lead equivalent are required in the fluoroscopy room for each person except the patient likely exposed to 50 µSv/hr (5 mR/hr) or more. Drapes and panels are required for…

    orsif.org/guidelines/us/states/arizona

  20. State rules

    Montana Radiation Safety Rules for Fluoroscopy Teams

    …in the fluoroscopy room except the patient must wear an apron of at least 0.25 mm lead equivalent, with the dosimeter at the collar outside the apron, but the rules do not require apron inspection and…

    orsif.org/guidelines/us/states/montana

20 studies in the members' research library match. Join free to search them