The Evidence
Resources
Clinician AssessmentGet Your Risk Score FAQs Admin ToolkitMembers Economic Impact Research ArticlesMembers SIRP 2025 WebinarMembers Videos
Guidelines
What is ALARA+? US Guidelines International Guidelines News Is Not Here About Contact Donate
Join Free

Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Radiological Health Program, Radiation, Toxics & Indoor Air Division, Office of Environmental Health Services (West Virginia Department of Health) as the agency that regulates X-ray and fluoroscopy equipment in West Virginia. West Virginia is not a U.S. Nuclear Regulatory Commission (NRC) Agreement State, so the NRC regulates radioactive materials there directly. The state still regulates X-ray machines. Letter of intent filed; not yet an Agreement State.

West Virginia requires ALARA in Section 6 of 64CSR23 (2001), which is shared by all registrants, and Section 7 adds X-ray-specific minimization language. The state is not an NRC Agreement State but is working toward an agreement under its 2024 Radiation Control Act. Dose limits are 50 mSv whole body, 150 mSv lens, 500 mSv skin and extremities, and 5 mSv to the embryo/fetus. All fluoroscopy workers must be badged. Aprons or whole-body barriers of at least 0.25 mm lead equivalent are required. There is no apron inspection rule and no specific provision on engineered shielding systems. Technologists must be licensed and, from 1 July 2026, hold national certification to renew. Licensed practitioners are exempt, and there is no physician fluoroscopy training rule.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is West Virginia an NRC Agreement State?

No

No. West Virginia is not an NRC Agreement State. The Governor sent a letter of intent on 9 January 2023, and HB 208 (2024) created the Radiation Control Act to support an agreement. The NRC showed no draft application submitted yet.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; NRC West Virginia page; W. Va. Code §16-27B
Source
nrc.gov
nrc.gov
What it says
West Virginia is not an Agreement State. The State has jurisdiction over x-ray equipment, naturally occurring radioactive materials, and certain radioactive materials that are not produced in a reactor.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in West Virginia?

Yes

Yes. 64CSR23, the Radiological Health Rule, effective 1 July 2001. Section 6 sets general radiation protection standards and Section 7 covers the healing arts, with fluoroscopy at §7.7. A 2020 revision was withdrawn on 6 November 2020.

Rule text and source
Rule
64CSR23 §§1.4, 6, 7
Source
apps.sos.wv.gov
What it says
1.4. Effective Date. -- July 1, 2001.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does West Virginia require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes. §6.4.b requires ALARA for occupational and public doses for all registrants. §7.3.a.9 adds a duty to minimize personnel exposure.

Where ALARA lives in West Virginia: In a shared rule and in X-ray-specific language. The formal ALARA duty (§6.4.b) is in Section 6, which is shared by all registrants, including radioactive-materials registrants (§11.1.b). Section 7 adds X-ray-specific minimization language (§7.3.a.9). §7.3.a.10 does not list §6.4, so ALARA reaches X-ray users through §6.1.a. (64CSR23 §§6.1.a, 6.4.b, 7.3.a.9, 7.3.a.10, 11.1.b, 2.1; W. Va. Code §16-27B-5(d))

Rule text and source
Rule
64CSR23 §6.1.a, §6.4.b; §7.3.a.9
Source
law.cornell.edu
What it says
The registrant shall use, to the extent practicable, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are as low as is reasonably achievable (ALARA).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual whole-body dose limit in West Virginia?

Yes

50 mSv (5 rem) TEDE per year for adults. Minors are limited to 10% of adult limits.

Rule text and source
Rule
64CSR23 §§6.5.a.1.A-B, 6.11
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

What is the annual eye-lens dose limit in West Virginia?

Yes

150 mSv (0.15 Sv) per year. No lower International Commission on Radiological Protection (ICRP)-style limit has been adopted.

Rule text and source
Rule
64CSR23 §6.5.a.2.A
Source
law.cornell.edu
What it says
6.5.a.2.A. An eye dose equivalent of fifteen one hundredths .15 Sv;
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in West Virginia?

Yes

500 mSv (50 rem) shallow dose per year to the skin or any extremity.

Rule text and source
Rule
64CSR23 §6.5.a.2.B
Source
law.cornell.edu
What it says
6.5.a.2.B. A shallow dose equivalent of five-tenths (0.5) Sv (fifty [50] Rem) to the skin or to any extremity.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in West Virginia?

Yes

5 mSv (0.5 rem) to the embryo/fetus of a declared pregnant woman over the whole pregnancy. If the fetus has already received more than 4.5 mSv when pregnancy is declared, a further 0.5 mSv is allowed.

Rule text and source
Rule
64CSR23 §§6.12.a, 6.12.d
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in West Virginia wear a dosimeter?

Yes

Adults likely to exceed 10% of a limit in a year must be monitored, as must minors and declared pregnant women likely to exceed 10% of their limits and anyone entering high or very high radiation areas. Everyone working with medical fluoroscopic equipment must be monitored, with no dose threshold.

Rule text and source
Rule
64CSR23 §6.17.a.2-a.5
Source
law.cornell.edu
What it says
6.17.a.2. Adults likely to receive, in 1 year from sources external to the body, a dose in excess of 10 percent of the limits in Subdivision 6.5.a.; … 6.17.a.5. Individuals working with medical fluoroscopic equipment;
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in West Virginia when a protective apron is worn?

Yes

The badge is worn at the collar outside the apron. A fetal badge goes at the waist under the apron and is required for a declared pregnant woman. With a single collar badge, the collar deep dose counts as effective dose, or collar × 0.3 if the reading exceeds 25% of the limit. The two-badge method uses 1.5 × waist (under apron) + 0.04 × collar (outside apron).

Rule text and source
Rule
64CSR23 §§6.5.c.2.A-C, 6.17.a.5.A-C, 6.18.a.1-a.4
Source
law.cornell.edu
What it says
multiplied by one and five-tenths (1.5) and the deep dose equivalent reported for the individual monitoring device located at the neck outside the protective apron multiplied by four one-hundredths (0.04).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in West Virginia fluoroscopy rooms wear protective aprons or other apparel?

Yes

Staff must be protected from scatter by aprons or whole-body barriers of at least 0.25 mm lead equivalent, and anyone who could be struck by the useful beam needs 0.5 mm. Facilities must keep enough aprons and gloves for all X-ray personnel. Fluoroscopy requires 0.25 mm above-table drapes or curtains in addition to the apron, with exemptions such as Table 64-23 S. Thyroid shields and eyewear are not required.

Rule text and source
Rule
64CSR23 §§7.3.a.5.A-B, 7.3.a.8.F, 7.7.h.1-3, Table 64-23 S
Source
law.cornell.edu
What it says
The x-ray operator, other staff, ancillary personnel, and other persons required for the medical procedure shall be protected from the direct scatter radiation by protective aprons or whole body protective barriers of not less than twenty five one-hundredths (0.25) millimeter lead equivalent material;
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in West Virginia address engineered protection systems used in place of aprons?

UnclearLess certain

Not specifically addressed. §7.3.a.5.B accepts 'protective aprons or whole body protective barriers', but 'whole body protective barrier' is not defined. Drapes and curtains under §7.7.h.2.B are required in addition to the apron, not instead of it.

Rule text and source
Rule
64CSR23 §§7.2.7, 7.3.a.5.B, 7.7.h.2.B
Source
law.cornell.edu
What it says
including, but not limited to, drapes, bucky-slot cover panel, or self-supporting curtains, in addition to any lead equivalency provided by the protective apron referred to in Paragraph 7.3.a.5.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in West Virginia?

In partLess certain

Licensed radiologic technologists, whose scope includes noninterpretive fluoroscopy. Licensed practitioners (medicine, osteopathy, podiatry, chiropractic, dentistry), radiologists and residents are exempt from the license. PAs and NPs are not exempt. Radiologist assistant status is uncertain after HB 5458 (2026).

Rule text and source
Rule
W. Va. Code §§30-23-2, 30-23-4(j), 30-23-10, 30-23-12; 64CSR23 §7.1; 18CSR1 §1.1
Source
code.wvlegislature.gov
What it says
(4) A licensed practitioner, Radiologist or Radiology resident; (5) A person licensed as a Radiologist Assistant under the West Virginia Board of Medicine;
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does West Virginia require to operate fluoroscopy equipment?

In part

Technologists need an accredited program and the Board exam. From 1 July 2026, active national certification (ARRT, NMTCB, ARMRIT or ASPMA) is required to renew. All operators must be adequately instructed (Table 64-23 P). There is no fluoroscopy-specific permit or physician fluoroscopy training rule.

Rule text and source
Rule
W. Va. Code §30-23-9; 18CSR1 §§1.4, 7.1-7.3; 64CSR23 §7.3.a.2, Table 64-23 P
Source
wvrtboard.gov
What it says
Active licensees who do not maintain active national certification after July 1, 2026, are not in compliance with the Board's continuing education requirements and may not renew their license until compliance is met.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Adopted rule18CSR1 technologist licensing rule

    Filed 2 April 2026, effective 1 July 2026, sunset 1 August 2031 (Jul 1, 2026)

    Requires active national certification for license renewal. Authorized by HB 4294 (2026).

    Source: wvrtboard.gov

  • Proposed ruleBoard of Medicine notice to repeal 11CSR9 (radiologist assistants)

    Notice filed 30 June 2026; comments closed 30 July 2026; final status unknown (Jun 30, 2026)

    Repeal of the radiologist assistant rule following HB 5458.

    Source: apps.sos.wv.gov

  • BillHB 5458 (2026)

    Enacted; passed 9 March 2026, effective 7 June 2026 (Mar 9, 2026)

    Repealed the radiologist assistant statute §30-3-7a.

    Source: code.wvlegislature.gov

  • BillSB 580 (2026)

    Not enacted; passed Senate 26 February 2026; last action: H To House Government Organization 02/27/26 (Feb 27, 2026)

    Would have rewritten §30-23, added PAs and APRNs to 'licensed practitioner', updated the technologist scope and moved RAs to the imaging Board.

    Source: wvlegislature.gov

1 other item the research logged (radiation therapy, industrial machines, fees and other subjects)
  • BillHB 208 (2024) Radiation Control Act / Agreement State effort

    Signed October 2024; NRC agreement still required, no draft application yet (2024-10)

    Created W. Va. Code §16-27B to support an NRC agreement and directs the agency to keep rules compatible with federal programs.

    Source: code.wvlegislature.gov

Also worth knowing

  • Every worker using medical fluoroscopic equipment must be badged regardless of expected dose (§6.17.a.5).
  • Table 64-23 S automatically exempts angiograms and several interventional procedures from the above-table drape and curtain requirement (§7.7.h.3).
  • Rooms where diagnostic X-ray is the only source are exempt from very-high-radiation-area access controls (§6.20.a), and diagnostic X-ray rooms need no caution signs (§6.28.e).
  • Registrants must review their radiation protection program at least every 12 months (§6.4.c), and workers can request a dose summary when they leave a job (§6.41.c).
  • The rule dates from 2001 and has no lens limit below 150 mSv.
  • The 2024 Act states a policy of 'compatibility and equivalency' with federal standards (§16-27B-1).

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Does the unretrieved 'Radiation Protection Program Guidelines' PDF address apron inspection, thyroid shields or eyewear? Ask the Radiological Health Program at (304) 352-5022.
  • Does a commercial engineered shielding system count as a 'whole body protective barrier' under §7.3.a.5.B?
  • Can PAs, APRNs and radiologist assistants operate fluoroscopy without a technologist license, and has the 11CSR9 repeal been finalized?
  • When will West Virginia submit a draft Agreement State application, and will new rules keep X-ray protection standards in a shared Section 6?
  • Cornell LII's copy of §6.15.a.1 has misplaced text; verify formal citations against the official SOS PDF.
  • Watch the 2027 session for bills reviving SB 580's §30-23 rewrite.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

  • The rule itself. Open "Rule text and source" under any answer, or read the sources listed below.
  • The state. Radiological Health Program. Program contacts in the CRCPD directory.
  • Your radiation safety officer. They know the federal, accreditation and facility requirements that apply at your site, which the state rules do not cover.

What may be missing here

  • 2 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 3 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ICRP
International Commission on Radiological Protection
TEDE
Total effective dose equivalent
All 20 sources the research read