Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. The research for this state ended before every question was fully answered, so some answers may be incomplete. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the No state agency regulates X-ray or fluoroscopy equipment; related bodies: Wyoming Office of Homeland Security Radiological Services Program (non-regulatory), Wyoming Board of Radiologic Technologist Examiners (operator licensing), Wyoming Occupational Safety and Health Administration (OSHA) (Department of Workforce Services), Wyoming Department of Health (hospital licensure), Wyoming DEQ Uranium Recovery Program (Agreement State program, not X-ray) as the agency that regulates X-ray and fluoroscopy equipment in Wyoming. Wyoming is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Wyoming has no state program that registers, inspects or sets radiation-safety rules for X-ray or fluoroscopy machines; its only radiation office is a non-regulatory emergency-preparedness program in the Office of Homeland Security. Wyoming is an Agreement State only for uranium and thorium milling, so the NRC regulates hospitals' radioactive materials directly. The only legal dose limits for fluoroscopy staff found come from Wyoming OSHA's adoption of 29 CFR 1910.1096, which counts the lens of the eye inside the 1.25 rem (12.5 mSv) per quarter whole-body limit. No state rule on lead aprons, apron inspection, badge placement or engineered alternatives was found. Licensed practitioners including PAs and APNs are exempt from operator licensing; technologists need a general license based on American Registry of Radiologic Technologists (ARRT), NMTCB or CBRPA certification, and limited-license holders may not perform fluoroscopy.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Wyoming an NRC Agreement State?

Yes

Yes, but only for uranium and thorium milling facilities and 11e.(2) byproduct material (signed 2018-09-25, effective 2018-09-30); a 2026 amended agreement adds source material recovered from mineral processing. NRC Region IV directly licenses medical radioactive materials in Wyoming.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; NRC, Wyoming: Agreement State Information
Source
nrc.gov
nrc.gov
What it says
assumed regulatory authority on September 30 over the regulation of uranium and thorium milling facilities
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Wyoming?

NoCheck the source

No state X-ray or fluoroscopy rules and no state Standards for Protection Against Radiation rule for X-ray users. Wyoming OSHA adopts 29 CFR 1910.1096 (reportedly as in effect June 8, 2016, unconfirmed); operator rules are at W.S. 33-37-101 to -113 and Board rules at Wyo. Code R. agency 017 (filed 2022-09-15).

Rule text and source
Rule
Wyo. Code R. 053-0025-26 § 26-1 (version 3 per LII); W.S. 33-37-101 et seq.; Wyo. Code R. 017
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

Does Wyoming require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Not foundCheck the source

not found

Where ALARA lives in Wyoming: No ALARA requirement found for X-ray users. No ALARA in Wyoming state law for X-ray and no unified state radiation-protection rule. Medical radioactive materials ALARA comes directly from NRC 10 CFR Part 20; X-ray worker protection rests on Wyoming OSHA's adoption of 29 CFR 1910.1096, which NRC compatibility does not govern; DEQ uranium recovery rules do not reach X-ray. (NRC Wyoming page; OSHA Ch. 26 § 26-1)

Rule text and source
Rule
Wyo. Code R. agency 017, Subagency 0001, App. A (ARRT Standards of Ethics)
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual whole-body dose limit in Wyoming?

YesCheck the source

1.25 rem (12.5 mSv) per calendar quarter under 29 CFR 1910.1096 as adopted by Wyoming OSHA (values from a secondary UW summary).

Rule text and source
Rule
29 CFR 1910.1096(b), adopted by Wyo. Code R. 053-0025-26 § 26-1
Source
uwyo.edu

Why this matters, in ORSIF's FAQs

What is the annual eye-lens dose limit in Wyoming?

NoCheck the source

No separate lens limit; the lens of the eye falls inside the 1.25 rem (12.5 mSv) per quarter whole-body limit. No lens-specific limit adopted.

Rule text and source
Rule
29 CFR 1910.1096(b), adopted by Wyo. Code R. 053-0025-26 § 26-1
Source
uwyo.edu

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Wyoming?

YesCheck the source

Hands and forearms, feet and ankles: 18.75 rem (187.5 mSv) per quarter; skin of whole body: 7.5 rem (75 mSv) per quarter (secondary values).

Rule text and source
Rule
29 CFR 1910.1096(b), adopted by Wyo. Code R. 053-0025-26 § 26-1
Source
uwyo.edu

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Wyoming?

UnclearCheck the source

UW table lists 0.5 rem (5 mSv) per gestation for the embryo/fetus of a declared pregnant woman under the 1910.1096 heading, but it may be university policy; not confirmed in 1910.1096.

Rule text and source
Rule
29 CFR 1910.1096(b), adopted by Wyo. Code R. 053-0025-26 § 26-1
Source
uwyo.edu

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Wyoming wear a dosimeter?

YesCheck the source

Under 29 CFR 1910.1096(d)(2) (per UW summary), dosimeters are required for adults in a restricted area likely to exceed 25% of a quarterly limit, workers under 18 likely to exceed 5% of the adult limit, and anyone entering a high radiation area. No Wyoming-specific threshold found.

Rule text and source
Rule
29 CFR 1910.1096(d)(2), via OSHA Ch. 26 § 26-1
Source
osha.gov

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Do the rules in Wyoming address engineered protection systems used in place of aprons?

Not foundLess certain

not found

Rule text and source

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Wyoming?

In partLess certain

Licensed practitioners (physicians, osteopaths, dentists, podiatrists, chiropractors, certified PAs, licensed APNs) are exempt from the licensing act. General-license technologists apply radiation under specific direction and may 'assist with fluoroscopy'; whether they may run fluoroscopy alone is not stated. Restricted-license technicians may not perform fluoroscopy. Students may operate under direct supervision.

Rule text and source
Rule
W.S. 33-37-102 (2025); Wyo. Code R. 017-3 § 3-2; 017-4 § 4-2
Source
law.justia.com
What it says
This act does not apply to: (i) Licensed practitioners as defined in W.S. 33-37-101(a)(iv)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Wyoming require to operate fluoroscopy equipment?

In part

General license requires an approved radiologic technology program (JRCERT or other ARRT-recognized accreditor) and the ARRT, NMTCB or CBRPA registry exam; continuing education (CE) follows ARRT renewal standards. No fluoroscopy permit or fluoroscopy-specific training found, including for physicians, PAs or APRNs.

Rule text and source
Rule
Wyo. Code R. 017-3 § 3-4; 017-6 § 6-4
Source
regulations.justia.com
What it says
General license holders shall earn continuing education hours based on the standards established for ARRT certification renewal.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

The research found nothing in this list that changes the rules for fluoroscopy teams.

2 other items the research logged (radiation therapy, industrial machines, fees and other subjects)
  • Proposed ruleWyoming OSHA, General Industry 1910 Ch. 26 (Subpart Z) update, ARR25-089P

    Notice of intent; OSHA Commission voted to adopt on September 12, 2025; final status and effect on 1910.1096 adoption date unknown

    Update to Wyoming OSHA's Subpart Z chapter; unknown whether it changes the 2016 adoption date for 29 CFR 1910.1096.

    Source: wyoleg.gov

  • Other2026 Amended State Agreement

    Listed on NRC page

    Adds source material recovered from mineral processing (such as rare-earth extraction); no effect on X-ray.

    Source: nrc.gov

Also worth knowing

  • Wyoming is one of the few states with no state X-ray machine registration or inspection program for medical facilities; worker protection rests mainly on Wyoming OSHA (1910.1096) and operator licensing.
  • Because physicians, PAs and APRNs are exempt from the licensing act, Wyoming law sets no fluoroscopy training requirement for those who most often run fluoroscopy in interventional labs.
  • Equipment performance standards come from the federal FDA (21 CFR 1020), which UW cites.
  • Dental X-ray inspections appear to be handled separately; 034-4 Wyo. Code R. § 4-5 'Radiograph Use' requires X-ray machine inspections, but the issuing board (agency 034) is unconfirmed.
  • The HLS Radiological Services Program describes itself as 'not a regulatory program.'
  • The research for Wyoming ended early, so some gaps remain.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Confirm from the text of 29 CFR 1910.1096 the exact quarterly limits, any provision allowing higher quarterly doses, the monitoring threshold, any ALARA-type wording, and whether the embryo/fetus limit is in the standard or only UW policy.
  • Open the official Wyoming OSHA Ch. 26 § 26-1 text (agency 053, subagency 0025) to confirm the adopted version date of 1910.1096; check whether ARR25-089P has been finalized and what it changed.
  • Confirm with the Wyoming Department of Health and HLS (Dillon Conner, 307-777-7197) that the state has no medical X-ray registration or inspection program, and whether any 2025-2026 bill proposes one or addresses apron alternatives.
  • Ask the Board of Radiologic Technologist Examiners whether general licensees may operate fluoroscopy themselves or only 'assist.'
  • Identify which board issues 034-4 § 4-5 and whether it reaches any medical fluoroscopy.
  • Check whether Wyoming OSHA's PPE rules (29 CFR 1910 Subpart I) are applied to lead aprons in practice.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 6 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 12 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • The research for this state ended before every question was fully answered, so some answers may be incomplete.
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ARRT
American Registry of Radiologic Technologists
OSHA
Occupational Safety and Health Administration
CE
Continuing education
All 20 sources the research read

Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.