The Evidence
Resources
Clinician AssessmentGet Your Risk Score FAQs Admin ToolkitMembers Economic Impact Research ArticlesMembers SIRP 2025 WebinarMembers Videos
Guidelines
What is ALARA+? US Guidelines International Guidelines News Is Not Here About Contact Donate
Join Free

Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. The research for this state ended before every question was fully answered, so some answers may be incomplete. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Montana Department of Public Health and Human Services (DPHHS) as the agency that regulates X-ray and fluoroscopy equipment in Montana. Montana is not a U.S. Nuclear Regulatory Commission (NRC) Agreement State, so the NRC regulates radioactive materials there directly. The state still regulates X-ray machines.

Montana's X-ray rules date mostly from 1980. ALARA appears only as advisory "should" language in the general Subchapter 7 standards, which are shared by licensees and registrants. Montana is not an NRC Agreement State. Dose limits are quarterly and follow the pre-1994 federal model: the lens is grouped with the whole body at 1¼ rem (12.5 mSv) per quarter, and no embryo/fetus limit was found. Everyone in the fluoroscopy room except the patient must wear an apron of at least 0.25 mm lead equivalent, with the dosimeter at the collar outside the apron. The rules reviewed do not address apron inspection, thyroid shields, eyewear or apron alternatives. Limited-permit operators may not perform fluoroscopy, and other operator rules remain unresolved.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Montana an NRC Agreement State?

No

No. Montana is not an NRC Agreement State. ARM 37.14.101 still refers to an agreement with the NRC, which appears to be leftover 1980 wording.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; ARM 37.14.101
Source
nrc.gov
law.cornell.edu

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Montana?

Yes

ARM 37.14 Subchapter 10, "X-Rays in the Healing Arts" (37.14.1001-1022), with fluoroscopy in 37.14.1006 and 37.14.1003. General standards are in Subchapter 7 (37.14.701-758). Most rules took effect 3/28/1980, and 37.14.1002 and 37.14.1003 were revised 10/31/2003. The research read the text on Cornell LII and Justia (current through September 20, 2024).

Rule text and source
Rule
ARM 37.14.701-758; ARM 37.14.1001-1022
Source
rules.mt.gov
law.cornell.edu
What it says
Subchapter 37.14.7 - Standards for Protection Against Radiation (Rule 37.14.701 to 37.14.758)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Montana require X-ray users to keep doses as low as reasonably achievable (ALARA)?

In partCheck the source

Advisory only: efforts "should" be made rather than "shall." The rule applies to all licensees and registrants, including X-ray registrants. It does not require an ALARA program.

Where ALARA lives in Montana: Only in a rule shared with radioactive materials. ALARA appears only in ARM 37.14.701, in Subchapter 7, which applies to all licensees and registrants. No ALARA wording was found in the X-ray rules reviewed (37.14.1003,.1006,.1012). 37.14.1003(5) references 10 CFR part 20 for shielding design only. (ARM 37.14.701(1); ARM 37.14.1003(5)(a))

Rule text and source
Rule
ARM 37.14.701(1)-(2)
Source
regulations.justia.com

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual whole-body dose limit in Montana?

Yes

1¼ rem (12.5 mSv) per calendar quarter. Up to 3 rem (30 mSv) per quarter is allowed if the lifetime 5(N-18) rem limit is met and dose history is documented on form MRH-30. Limits are quarterly and are not expressed as total effective dose equivalent (TEDE).

Rule text and source
Rule
ARM 37.14.705(1)-(3)
Source
law.cornell.edu
What it says
As used in (3), "dose to the whole body" shall be deemed to include any dose to the whole body, gonads, active blood-forming organs, head and trunk, or lens of eye.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual eye-lens dose limit in Montana?

In part

There is no separate lens limit. The lens is grouped with the whole body at 1¼ rem (12.5 mSv) per quarter. No modern lens limit (such as International Commission on Radiological Protection (ICRP)'s 20 mSv) has been adopted.

Rule text and source
Rule
ARM 37.14.705(1)-(3)
Source
law.cornell.edu
What it says
As used in (3), "dose to the whole body" shall be deemed to include any dose to the whole body, gonads, active blood-forming organs, head and trunk, or lens of eye.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Montana?

Yes

Hands, forearms, feet and ankles: 18¾ rem (187.5 mSv) per quarter. Skin of whole body: 7½ rem (75 mSv) per quarter.

Rule text and source
Rule
ARM 37.14.705(1)-(3)
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Montana wear a dosimeter?

YesCheck the source

Generally required if a worker is likely to exceed 25% of a quarterly limit (5% for workers under 18). The X-ray rules require monitoring for at least a 13-week period starting each January. For fluoroscopy, monitoring is required for everyone who enters a controlled area.

Rule text and source
Rule
ARM 37.14.1006(3)(h); 37.14.721(1); 37.14.1003(3); 37.14.1012(3)(a)
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Montana when a protective apron is worn?

Yes

When an apron is worn, the badge goes at the collar outside the apron. The research found no two-badge method and no method for calculating effective dose equivalent.

Rule text and source
Rule
ARM 37.14.1003(3)
Source
regulations.justia.com
What it says
When a protective apron is worn, the monitoring device shall be worn at the collar outside of the apron.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Montana fluoroscopy rooms wear protective aprons or other apparel?

In part

Aprons of at least 0.25 mm lead equivalent are required for everyone in the fluoroscopy room except the patient. Thyroid shields and eyewear are not addressed in the rules reviewed.

Rule text and source
Rule
ARM 37.14.1006(3)(d)
Source
law.cornell.edu
What it says
Protective aprons of at least 0.25 millimeters lead equivalent shall be worn in the fluoroscopy room by each person except the patient.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Montana address engineered protection systems used in place of aprons?

No

Not addressed. The only related provision is a general waiver that applies if the registrant shows equivalent protection by other means; it does not mention aprons or engineered systems.

Rule text and source
Rule
ARM 37.14.1003(1)
Source
regulations.justia.com
What it says
The department may waive compliance with the specific requirements of this subchapter by an existing machine or installation if the registrant demonstrates, to the department's satisfaction, achievement through other means of radiation protection equivalent to that required by this chapter.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Montana?

In partCheck the source

Only partly answered. People who take X-ray exposures must be licensed by the state board. Limited permit holders (104-hour training) may not perform fluoroscopy. Registrants must ensure only competent persons use sources. Physician, PA/NP and supervision rules were not found.

Rule text and source
Rule
ARM 24.204.504(3); ARM 37.14.1003(4)(a)
Source
law.cornell.edu
boards.bsd.dli.mt.gov

Why this matters, in ORSIF's FAQs

What training or credentials does Montana require to operate fluoroscopy equipment?

In partCheck the source

The RT license is based on ARM 24.204.408 and MCA 37-14-302; a secondary source says Montana requires American Registry of Radiologic Technologists (ARRT) certification/registration. Limited permits require 104 hours of training and exclude fluoroscopy. No state fluoroscopy permit, physician fluoroscopy training rules or continuing education requirements were found.

Rule text and source
Rule
ARM 24.204.408; MCA 37-14-302; ARM 24.204.504
Source
boards.bsd.dli.mt.gov
forsythtech.edu

Why this matters, in ORSIF's FAQs

Also worth knowing

  • The core rules (effective 3/28/1980) follow the pre-1994 federal model: quarterly limits, the 5(N-18) lifetime formula, "dose" rather than TEDE, and no declared-pregnant-worker provision.
  • The fluoroscopist must dark-adapt their eyes for 20 minutes, and a cumulative timer must signal at no more than 5 minutes.
  • Only persons whose presence is necessary may be in the fluoroscopy room (37.14.1006(3)(e)), and occupationally exposed staff may not routinely hold patients in radiography (37.14.1012(3)(b)).
  • Every installation must have a radiation safety officer, whose duties include investigating each known or suspected excessive exposure (37.14.1003(4)(b)-(c)).
  • Overexposures above 37.14.705 limits must be reported in writing within 30 days (37.14.756).
  • The licensing board's web page refers to the "Montana Allied Healthcare Board," while the rules still name the Board of Radiologic Technologists.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • The research for Montana ended early, so the answers on who may operate the equipment, operator training and pending changes are incomplete, as are parts of the dose-limit and apron-inspection answers.
  • Read MCA Title 37, ch. 14 (37-14-301 to 37-14-306) for physician and practitioner licensing exemptions, PA/NP authority and supervision, and read ARM 24.204 in full for continuing education and fluoroscopy training.
  • Review ARM 37.14 Subchapter 17 (37.14.1701-1721) for prenatal-exposure or worker-instruction rules, and check the full text of 37.14.706,.708 and.729.
  • Search the Montana Administrative Register for 2025-2026 DPHHS notices on ARM 37.14 and the 2025 legislative session for related bills, and ask DPHHS whether a modernization of the rules is planned.
  • Confirm the current rule text on the official ARM site (rules.mt.gov).
  • Check whether the Board of Radiologic Technologists has been merged into an "Allied Healthcare Board."
  • Ask DPHHS what the ARM 37.14.101 reference to an agreement with the NRC means.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 2 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 6 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • The research for this state ended before every question was fully answered, so some answers may be incomplete.
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ICRP
International Commission on Radiological Protection
TEDE
Total effective dose equivalent
ARRT
American Registry of Radiologic Technologists
All 15 sources the research read