234 results for “eye lens dose limit”, 52 in State rules.

Results

  1. State rules

    Minnesota Radiation Safety Rules for Fluoroscopy Teams

    ALARA for X-ray users Yes X-ray rule. Whole-body limit 5 rem (50 mSv) total effective dose equivalent per year. Eye-lens limit 150 mSv a year. Apron inspection Required

    orsif.org/guidelines/us/states/minnesota

  2. State rules

    District of Columbia Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 0.05 Sv (5 rem) total effective dose equivalent (TEDE) per year (50 mSv), per posted Part D. Eye-lens limit 150 mSv a year. Apron inspection Not found

    orsif.org/guidelines/us/states/district-of-columbia

  3. State rules

    Florida Radiation Safety Rules for Fluoroscopy Teams

    …no ALARA wording of its own. Florida uses the standard US dose limits: 50 mSv a year whole body, 150 mSv lens of the eye (the lower International Commission on Radiological Protection (ICRP) 20 mSv…

    orsif.org/guidelines/us/states/florida

  4. State rules

    Pennsylvania Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 5 rem (50 mSv) total effective dose equivalent (TEDE) per year, from 10 CFR Part 20 as adopted through § 219.5. Eye-lens limit 150 mSv a year. Apron inspection Not found

    orsif.org/guidelines/us/states/pennsylvania

  5. State rules

    North Carolina Radiation Safety Rules for Fluoroscopy Teams

    …requires X-ray and fluoroscopy facilities to keep worker doses ALARA by adopting 10 CFR 20.1101 into one state rule, 10A NCAC 15.1601, which covers both X-ray registrants and radioactive-materials…

    orsif.org/guidelines/us/states/north-carolina

  6. State rules

    Hawaii Radiation Safety Rules for Fluoroscopy Teams

    …requires X-ray and fluoroscopy facilities to keep worker doses ALARA under the general standards subchapter (HAR 11-45, subchapter 4), which the X-ray subchapter applies to X-ray workers while adding…

    orsif.org/guidelines/us/states/hawaii

  7. State rules

    West Virginia Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 50 mSv (5 rem) total effective dose equivalent (TEDE) per year for adults. Eye-lens limit 150 mSv a year. Apron inspection Not found. Alternatives to aprons In part

    orsif.org/guidelines/us/states/west-virginia

  8. State rules

    Delaware Radiation Safety Rules for Fluoroscopy Teams

    …D requires every licensee or registrant to keep worker doses ALARA. Delaware is not an NRC Agreement State, so an NRC compatibility change would not automatically reach its rule. Dose limits follow…

    orsif.org/guidelines/us/states/delaware

  9. State rules

    North Dakota Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit Total effective dose equivalent (TEDE) of 5 rem (50 mSv) per year, or 50 rem (500 mSv) to any organ other than the lens. Eye-lens limit 150 mSv a year

    orsif.org/guidelines/us/states/north-dakota

  10. State rules

    Tennessee Radiation Safety Rules for Fluoroscopy Teams

    ALARA for X-ray users Yes Shared rule. Whole-body limit 5 rem (50 mSv) per year total effective dose equivalent. Eye-lens limit 150 mSv a year. Apron inspection Not found

    orsif.org/guidelines/us/states/tennessee

  11. State rules

    New Jersey Radiation Safety Rules for Fluoroscopy Teams

    …the shared part but not the X-ray-specific sentence. Dose limits are federal: 50 mSv whole body, 150 mSv lens, 500 mSv skin/extremities, and 5 mSv embryo/fetus; no lower eye limit has been adopted.…

    orsif.org/guidelines/us/states/new-jersey

  12. State rules

    Texas Radiation Safety Rules for Fluoroscopy Teams

    Whole-body limit 5 rem (50 mSv) total effective dose equivalent (TEDE) per year; minors 10% of adult limits. Eye-lens limit 150 mSv a year. Apron inspection Required

    orsif.org/guidelines/us/states/texas