Search
188 results for “lead apron”.
Results
State rules
Maine Radiation Safety Rules for Fluoroscopy Teams
Staff must be protected from scatter by protective aprons or whole-body protective barriers of at least 0.25 mm lead equivalent, and anyone who could be struck by the useful beam needs at least 0.5…
orsif.org/guidelines/us/states/maine
State rules
Kansas Radiation Safety Rules for Fluoroscopy Teams
…mSv skin or extremities, and 5 mSv to the embryo/fetus. Aprons or whole-body protective barriers of at least 0.25 mm lead equivalent are required, but the rules do not require aprons to be inspected…
orsif.org/guidelines/us/states/kansas
Research summary
An In-depth Analysis of the Adverse Effects of Ionizing Radiation Exposure on Cardiac Catheterization Staffs
Lead aprons, thyroid shields, monitoring devices, minimizing fluoroscopy time and maximizing distance are described as key protective measures.
orsif.org/research/an-in-depth-analysis-of-the-adverse-effects-of-ionizing-radiation-exposure-on
Research summary
Musculoskeletal disorders in interventional radiology workers: an integrative review
…heavy protective apparel, though a causal link with aprons is not established. Lighter, more ergonomic shielding is under development.
orsif.org/research/musculoskeletal-disorders-in-interventional-radiology-workers-an-integrative
State rules
New York Radiation Safety Rules for Fluoroscopy Teams
…fluoroscopy room must wear garments of at least 0.25 mm lead equivalent, except around tabletop mini C-arms; a new 2026 provision allows an equivalent dose reduction method instead, if measurements…
orsif.org/guidelines/us/states/new-york
State rules
South Dakota Radiation Safety Rules for Fluoroscopy Teams
…possible and checked annually, but there is no minimum lead equivalence for staff aprons, no mention of thyroid shields or eyewear, and nothing on engineered shielding systems used instead of aprons.…
orsif.org/guidelines/us/states/south-dakota
Research summary
Occupational Radiological Protection in Interventional Procedures, ICRP PUBLICATION 139
…monitoring, eye lens and extremity dose assessment, aprons, ceiling shields, eyewear, garment testing, training and audits. It cites lens opacity rates reported among interventionists and nurses in…
orsif.org/research/occupational-radiological-protection-in-interventional-procedures-icrp
Research summary
AORN Guideline - Radiation Safety
…radiation safety officer, dosimetry, inspected and tested lead protection, radiation safety time outs, extra measures for pregnant staff, ongoing training and annual program review for OR fluoroscopy…
orsif.org/research/aorn-guideline-radiation-safety
Research summary
Radiation safety compliance awareness among healthcare workers exposed to ionizing radiation
Many never used a dosimeter, lead apron or thyroid collar. (47.14% never used dosimeter; 36.2% never wore apron; 57% never wore collar)
orsif.org/research/radiation-safety-compliance-awareness-among-healthcare-workers-exposed-to
Research summary
Reproductive effects of low to moderate medical radiation exposure
In interventional cardiologists, gonad dose under the lead apron is similar in magnitude to the shielded thyroid dose, about 50 to 100 microSv per cine-angiography procedure, and up to ten-fold higher…
orsif.org/research/reproductive-effects-of-low-to-moderate-medical-radiation-exposure
State rules
Connecticut Radiation Safety Rules for Fluoroscopy Teams
There is no apron, thyroid shield or eyewear requirement for human fluoroscopy staff. Aprons are required only for operators of hand-held low-voltage therapy tubes (§ 19-25d-10, no lead value stated)…
orsif.org/guidelines/us/states/connecticut
US guidelines
U.S. Radiation Safety Regulatory Hierarchy
Some states require specific exams (e.g., California). Lead apron specifications differ (0.25mm to 0.5mm). Training hour requirements vary by state. Accreditation
orsif.org/guidelines/us/hierarchy.html
Research summary
Body pain, An unheeded personal health hazard in interventional cardiologists: A national online cross-sectional survey study in China
…matched non-interventional colleagues, and most said heavy lead aprons took a physical toll. Findings are self-reported associations.
orsif.org/research/body-pain-an-unheeded-personal-health-hazard-in-interventional-cardiologists-a
Research summary
Radiation Protection Practices Among Medical Students at Two United Kingdom Medical Schools
Only half reported that their lead apron adequately covered breast and axillary regions. (35/70 (50%) adequate; 29/70 (41%) not)
orsif.org/research/radiation-protection-practices-among-medical-students-at-two-united-kingdom
State rules
Utah Radiation Safety Rules for Fluoroscopy Teams
…other staff must be protected from scatter by protective aprons or barriers unless distance keeps exposure within the R313-15-201 limits. Facilities must have enough aprons and gloves for unshielded…
orsif.org/guidelines/us/states/utah
Research summary
AST Standards for Ionizing Radiation Exposure
…for surgical technologists and assistants: training, apron inspection and storage, time-distance-shielding, dosimeter placement, eye and thyroid protection, pregnancy policies and radionuclide…
orsif.org/research/ast-standards-for-ionizing-radiation-exposure
Research summary
The head of invasive cardiologists as a target of professional exposure to ionizing radiation
…head doses up to ten times greater than chest doses under lead aprons, with the left brain hemisphere reaching up to 2 Sv over a professional lifetime. (up to ten times; up to 2 Sv (equivalent to…
orsif.org/research/the-head-of-invasive-cardiologists-as-a-target-of-professional-exposure-to
State rules
Tennessee Radiation Safety Rules for Fluoroscopy Teams
…no badge location or two-badge method. "Collar outside the leaded apron" wording appears elsewhere in 0400-20-06, apparently in the veterinary rule (unconfirmed). The deep-dose reading is used unless…
orsif.org/guidelines/us/states/tennessee
Research summary
Performance of a radiation protection cabin during extraction of cardiac devices
Authors conclude the cabin provides nearly full-body protection and removes the need for a lead apron.
orsif.org/research/performance-of-a-radiation-protection-cabin-during-extraction-of-cardiac-devices
Research summary
Radiation exposure in interventional cardiology: Implications for patients and healthcare workers
Staff doses were measured with TLDs placed both under and above lead aprons.
orsif.org/research/radiation-exposure-in-interventional-cardiology-implications-for-patients-and
20 studies in the members' research library match. Join free to search them