Search

209 results for “dosimeter”, 126 in Research summaries.

Results

  1. Research summary

    Operator radiation exposure during transradial coronary angiography: Effect of single vs. double catheters

    …high-volume center, diagnostic procedures only, with one dosimeter worn over the apron at the chest rather than measuring eye or under-apron dose; abstract reports no p-value for the operator dose…

    orsif.org/research/operator-radiation-exposure-during-transradial-coronary-angiography-effect-of

  2. Research summary

    AORN Guideline - Radiation Safety

    Pregnant team members should follow regulatory dose limits, wear a wraparound apron and wear a second dosimeter at waist level under the apron.

    orsif.org/research/aorn-guideline-radiation-safety

  3. Research summary

    New Image-Processing And Noise-Reduction Software Reduces Radiation Dose During Complex Endovascular Procedures

    …measured in the abstract. Operator dose came from one dosimeter outside the apron, converted to an effective-dose estimate.

    orsif.org/research/new-image-processing-and-noise-reduction-software-reduces-radiation-dose-during

  4. Research summary

    Radiation Dose to the Breast in Occupationally Exposed Healthcare Professionals: A Case Series

    In three women working in angiography procedures, dosimeters under lead garments detected low but measurable breast dose in two, possibly linked to armhole gaps and working distance. The sample is…

    orsif.org/research/radiation-dose-to-the-breast-in-occupationally-exposed-healthcare-professionals

  5. Research summary

    Reduction of Operator Radiation Dose by a Pelvic Lead Shield During Cardiac Catheterization by Radial Access: Comparison With Femoral Access

    Limits: Single operator with one dosimeter outside the apron at chest level, so results may not generalize to other operators, staff or organ doses; abstract only, elective diagnostic angiography,…

    orsif.org/research/reduction-of-operator-radiation-dose-by-a-pelvic-lead-shield-during-cardiac

  6. Research summary

    Trends in Occupational Radiation Doses

    …US radiologic technologists not doing interventional work, badge doses from general radiography fell to undetectable levels by 2015, while doses for those doing nuclear medicine, especially cardiac…

    orsif.org/research/trends-in-occupational-radiation-doses

  7. Research summary

    The occupational effects of interventional cardiology: results from the WIN for Safety survey

    The thyroid shield was the most used protective measure, and about two-thirds wore a collar badge. (87.2% thyroid shield; 64.4% collar badge)

    orsif.org/research/the-occupational-effects-of-interventional-cardiology-results-from-the-win-for

  8. Research summary

    Operator Radiation Exposure During Percutaneous Coronary Procedures Through The Left Or Right Radial Approach: the TALENT dosimetric substudy

    Limits: Only three operators with monthly pooled dosimeter readings, limiting statistical power and generalisability; randomisation was of patients, not operators, and the country and centre are not…

    orsif.org/research/operator-radiation-exposure-during-percutaneous-coronary-procedures-through-the

  9. Research summary

    National medical occupational radiation dose monitoring in Saudi Arabia

    …records reporting averages by practice, with no detail on dosimeter placement, workload, or roles within interventional radiology. Effective dose may not reflect lens or extremity doses or individual…

    orsif.org/research/national-medical-occupational-radiation-dose-monitoring-in-saudi-arabia

  10. Research summary

    Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms

    …Nonrandomized two-center dosimetry study with single-use dosimeters at one eye-level and one finger position; the abstract does not report absolute dose values, use of protective eyewear, or the…

    orsif.org/research/radiation-exposure-to-eye-lens-and-operator-hands-during-endovascular-procedures

  11. Research summary

    Use of O-arm navigation in percutaneous pedicle screw fixation for thoracolumbar fractures in patients with ankylosing spinal disorders: reducing intraoperative radiation exposure-a retrospective cohort study

    Limits: Small single-center retrospective study (24 patients) with non-random allocation by time of day. Fluoroscopy time was a surrogate; no actual staff dose or dosimeter data were collected.

    orsif.org/research/use-of-o-arm-navigation-in-percutaneous-pedicle-screw-fixation-for-thoracolumbar

  12. Research summary

    Dose Evaluation of Medical Staff During Proximal Femur Fracture Surgery Using Fluoroscopy

    The glabella (forehead) was identified as the most appropriate eye lens dosimeter location; highest hand doses occurred in complex subtrochanteric fractures.

    orsif.org/research/dose-evaluation-of-medical-staff-during-proximal-femur-fracture-surgery-using

  13. Research summary

    Literacy in the Scope of Radiation Protection for Healthcare Professionals Exposed to Ionizing Radiation: A Systematic Review

    Knowledge of regulatory legislation on radiation safety was unsatisfactory; dosimetry knowledge and use were mixed, with one study reporting only half of professionals used dosimeters.

    orsif.org/research/literacy-in-the-scope-of-radiation-protection-for-healthcare-professionals

  14. Research summary

    Reduction of Radiation Exposure Using Dynamic Trace Digital Angiography and Spot Fluoroscopy During Adrenal Venous Sampling

    Limits: Very small two-group comparison (11 patients each) with no stated randomization or design details, in a single procedure type; operator dose is a dosimeter measurement, not a health outcome.

    orsif.org/research/reduction-of-radiation-exposure-using-dynamic-trace-digital-angiography-and-spot

  15. Research summary

    Radiation protection knowledge and self-reported compliance with safety practices among radiology, nuclear medicine, radiotherapy, and interventional/fluoroscopy professionals in Türkiye: A cross-sectional survey

    Most respondents reported wearing personal dosimeters and reviewing dosimetry reports. (133/153, 86.9%; 123/149, 82.6%)

    orsif.org/research/radiation-protection-knowledge-and-self-reported-compliance-with-safety

  16. Research summary

    Novel radiation dose reduction fluoroscopic technology facilitates chronic total occlusion percutaneous coronary interventions

    …reduction is inferred rather than measured with personal dosimeters.

    orsif.org/research/novel-radiation-dose-reduction-fluoroscopic-technology-facilitates-chronic-total

  17. Research summary

    Evidence for the lack of an increase in DNA damage in occupational healthcare workers exposed to ionizing radiation: An indication of radiation safety

    Biomarkers correlated only weakly with cumulative registered thermoluminescent dosimeter (TLD) dose. (γ-H2AX R2=0.0123; MN R2= 0.0011; FDXR R2= 0.0006)

    orsif.org/research/evidence-for-the-lack-of-an-increase-in-dna-damage-in-occupational-healthcare

  18. Research summary

    Radiation exposure during cardiac device implantation: Lessons learned from a multicenter registry

    Limits: Observational registry with abstract only; staff dosimeter results are not reported in the abstract, and system comparisons may be confounded by center practices.

    orsif.org/research/radiation-exposure-during-cardiac-device-implantation-lessons-learned-from-a

  19. Research summary

    Lightweight bilayer barium sulfate-bismuth oxide composite thyroid collars for superior radiation protection in fluoroscopy-guided interventions: a prospective randomized controlled trial

    …available in only 117 of 256 data sets; outcome is dosimeter dose rather than health effects, and comfort was self-rated by unblinded operators.

    orsif.org/research/lightweight-bilayer-barium-sulfate-bismuth-oxide-composite-thyroid-collars-for

  20. Research summary

    A safety radiation marker in the cardiac catheterization lab

    …a single, unnamed centre; the abstract does not describe dosimeter placement, shielding used, or how absorbed dose was measured, and some units (e.g. 15,253) are unreported.

    orsif.org/research/a-safety-radiation-marker-in-the-cardiac-catheterization-lab

9 studies in the members' research library match. Join free to search them