Research summary, original research, 2026

[The Multicenter Radiation Dose Survey for Catheter Ablation of Arrhythmia: Actual Conditions and Technique-specific Comparison after the DRLs 2020 Revision]

Sato M, Maekawa K, Hayashi T, Hasegawa R, Noguchi K, Takeda K, et al.. Nihon Hoshasen Gijutsu Gakkai zasshi. 2026

Read the original paper

In plain language

In a Japanese multicenter survey of catheter ablation, median patient reference air kerma was 128 mGy for non-pulmonary vein isolation (PVI), 170 mGy for catheter PVI and 228 mGy for balloon PVI. These are patient dose indices, not measured staff exposure.

At a glance

Type of study
Original research, Retrospective cohort study
Who was studied
Patients
Where
Japan
Summary based on
the abstract

What it found

  • Median patient reference air kerma differed by ablation technique, highest for balloon PVI.

    Key figures: Median Ka,r 128 mGy (non-PVI), 170 mGy (catheter PVI), 228 mGy (balloon PVI)

  • Kerma-area product (PKA), fluoroscopy time, cine runs and cine frames differed significantly among the three techniques.

    Key figures: p<0.05

  • Radiation dose in catheter ablation showed a downward trend, though balloon PVI remained higher than other methods.

  • Authors recommend continuous dose monitoring and use of the data for future diagnostic reference level (DRL) revisions.

Limits to keep in mind

Retrospective nationwide survey summarised only in an abstract; number of institutions and procedures not reported. Measures patient dose indices, not staff dose.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.