Ordiales JM, Nogales JM, Vano E, López-Mínguez JR, Alvarez FJ, Ramos J, et al.. Radiation protection dosimetry. 2016

Read the original paper

In plain language

In a randomised cath lab study, placing a shielding drape on the patient was associated with a 50% lower median dose to interventional cardiologists and 31% lower maximum scatter dose. These are dosimeter readings, not health outcomes.

At a glance

Type of study
Original research, Randomized trial
Who was studied
Interventional cardiologists, Patients
Summary based on
the abstract

What it found

  • The median dose received by the interventional cardiologist was 50% lower when a shielding drape was placed on the patient.

    Key figures: 50% lower; p<0.001

  • The median maximum scatter radiation dose was 31% lower in the shielding drape group.

    Key figures: 31% lower; p<0.001

  • The randomised groups did not differ significantly in procedural control parameters such as fluoroscopy time, kerma-area product and cine images, supporting comparability.

Limits to keep in mind

Only the abstract was available; sample size, country, drape type and dosimeter placement are not reported. Outcomes are dosimeter readings rather than health effects, and only the cardiologist's dose is described.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.