Extended Protective Shield Under Table to Reduce Operator Radiation Dose in Percutaneous Coronary Procedures: The EXTRA-RAD Study

Sciahbasi A, Sarandrea A, Rigattieri S, Patrizi R, Cera M, Di Russo C, et al.. Circulation. Cardiovascular interventions. 2019

Read the original paper

In plain language

In a single-center randomized study of 205 transradial coronary procedures, adding an under-table shield (curtain or drape) roughly tripled the reduction in operators' pelvic dose and halved thorax dose, with both shield types performing similarly.

At a glance

Type of study
Original research, Randomized trial
Who was studied
Interventional cardiologists, Patients
Size
n = 205 procedures
Summary based on
the abstract

What it found

  • Adjunctive under-table shields were associated with lower operator pelvic dose than no shield.

    Key figures: 42 µSv [14-98] vs 13 µSv [5-27]; P<0.0001

  • Operator thorax dose was also lower with adjunctive shields.

    Key figures: 4 µSv [1-13] vs 2 µSv [1-4]; P=0.001

  • Dose reduction was seen for every operator.

    Key figures: 4 operators

  • A small curtain and a drape under the table gave similar pelvic doses.

    Key figures: P=0.183

Limits to keep in mind

Single-center study with only 4 operators and transradial procedures only; dosimeter-measured dose rather than health outcomes, and country and dosimeter details are not stated in the abstract.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.