Research summary, original research, 2026

From whole-body dosimetry to local dose assessment: a 3-y experience in interventional practice

Filice S. Radiation protection dosimetry. 2026

Read the original paper

In plain language

In ten interventional radiologists and cardiologists followed for three years, chest dosemeter readings tracked eye-lens and hand doses fairly closely. Conversion factors differed by specialty, so estimates from chest badges are a stopgap, not a substitute for dedicated eye and extremity dosimetry.

At a glance

Type of study
Original research, Dosimetry measurement study
Who was studied
Interventional radiologists, Interventional cardiologists
Size
n = 180 paired dosimetry records
Summary based on
the abstract

What it found

  • Whole-body chest dosemeter readings correlated moderately to strongly with eye-lens and extremity doses.

    Key figures: r = 0.86-0.91, R2 = 0.73-0.83

  • The eye-lens conversion coefficient was higher in cardiologists than in the radiology group, supporting group-specific coefficients.

    Key figures: 1.8 vs 0.68

  • Most variance was within-operator rather than between operators.

    Key figures: inter-operator 20%-25%; within-operator 75%-80%

  • Conversion coefficients varied substantially, reflecting heterogeneous exposure conditions.

    Key figures: CV ~30% for k1, 27% for k2

Limits to keep in mind

Retrospective analysis of only ten operators at what appears to be a single programme, with large within-operator variability; the abstract does not report shielding use or the country.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.

Prepared November 3, 2026.