Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians

Fetterly K, Schueler B, Grams M, Sturchio G, Bell M, Gulati R. JACC. Cardiovascular interventions. 2017

Read the original paper

In plain language

In a phantom model of an interventional physician, leaded glasses lowered lens dose by 27% to 62% only on the scatter-facing eye, and a radioabsorbent cap lowered brain dose by 3.3%. Collar dosimeter readings can help estimate head and neck dose.

At a glance

Type of study
Original research, Phantom or simulation study
Who was studied
Phantom or simulation (no people), Interventional cardiologists, Interventional radiologists
Summary based on
the abstract

What it found

  • Unprotected brain, carotid artery and ocular lens doses were a fraction of the left collar dosimeter reading, allowing estimation of head and neck dose from personal dosimeters.

    Key figures: 8.4%, 17%, and 50% of collar dose

  • Leaded glasses reduced lens dose on the side facing the scatter source but did not protect the opposite eye.

    Key figures: 27% to 62% reduction

  • A radioabsorbent surgical cap gave minimal brain dose reduction.

    Key figures: 3.3%

Limits to keep in mind

Phantom study using a single representative geometry with radiochromic film; results may not generalize to other projections, operator positions or real clinical conditions, and no health outcomes were measured.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.