Research summary, original research, 2026

Diagnostic Radiographers' Application of the Radiation Protection Principles of Justification, Optimisation and Dose Limits in Mpumalanga Province, South Africa

Mkhonza WW, Lewis S, Badriparsad NR. Journal of medical radiation sciences. 2026

Read the original paper

In plain language

In a survey of 125 diagnostic radiographers in Mpumalanga, South Africa, most were issued dosimeters but only half reported always wearing them, a third received readings, and lead goggles and gloves were often unavailable.

At a glance

Type of study
Original research, Cross-sectional survey
Who was studied
Radiologic technologists
Size
n = 125 diagnostic radiographers
Where
South Africa
Summary based on
the full text

What it found

  • Nearly all radiographers were issued a personal dosimeter, but only about half always wore it and one third always received their dose readings.

    Key figures: 97.1% issued; 53.5% always wore; 33.3% always received readings

  • Dosimeters were most often placed under the lead apron regardless of apparel worn, contrary to guidance for apron-only use.

    Key figures: 50.6% always under apron (apron only); 51.9% (apron plus thyroid shield)

  • Full lead aprons were almost universally available, while lead goggles and gloves were least available; availability of thyroid shields, gloves and goggles varied by hospital type.

    Key figures: aprons 98.1%; thyroid shields 87.3%; lead gloves 53.9%; lead goggles 33.7%

  • Most referral forms lacked sufficient clinical history, and many radiographers never discussed incomplete referrals with radiologists.

    Key figures: 64.8% insufficient history; 31.3% never discussed with radiologists

  • Two thirds felt their expertise in justification was undervalued due to hierarchy.

    Key figures: 66.4% (n = 81)

Limits to keep in mind

Self-reported cross-sectional survey of hospital radiographers in one rural South African province, with distribution via department heads that may introduce selection bias; only about half worked in fluoroscopy and few in angiography or cardiac cath.

How this summary was made

ORSIF prepared this summary with AI assistance from the full text of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.

Prepared November 3, 2026.