Research summary, original research, 2014

An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures

2014

Read the original paper

In plain language

In interventional radiology, toe doses for radiologists were higher than expected, with two of four projected near 110 mSv a year. Table curtains reduced lower-leg exposure but left toes partly exposed, especially with gaps below the curtain.

At a glance

Type of study
Original research, Dosimetry measurement study
Who was studied
Interventional radiologists, Phantom or simulation (no people)
Size
n = 4 radiologists (in situ toe monitoring)
Summary based on
the abstract

What it found

  • In situ monitoring projected annual toe doses near the 150 mSv classification threshold for two of four radiologists.

    Key figures: 110 mSv annual toe dose

  • Protective under-table curtains reduced exposure to most of the lower extremities.

  • Toe doses were high and rose as couch height increased.

  • Curtains may not fully protect the toes, especially when there is a gap below them; stepping back from the couch is advised.

  • Authors recommend including lower legs and toes in local radiation protection programmes.

Limits to keep in mind

Only four radiologists were monitored for 7 weeks, with annual doses extrapolated; much of the data come from ionization chamber and phantom measurements, and the abstract gives few quantitative details.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.

Prepared November 5, 2026.