The Evidence
Resources
Clinician AssessmentGet Your Risk Score FAQs Admin ToolkitMembers Economic Impact Research ArticlesMembers SIRP 2025 WebinarMembers Videos
Guidelines
What is ALARA+? US Guidelines International Guidelines News Is Not Here About Contact Donate
Join Free

Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Nebraska Department of Health and Human Services (DHHS), Division of Public Health, Office of Radiological Health as the agency that regulates X-ray and fluoroscopy equipment in Nebraska. Nebraska is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Nebraska requires X-ray registrants, including fluoroscopy facilities, to keep doses ALARA under 180 NAC 4, a chapter shared with radioactive-materials licensees; Chapter 6 has only related "minimize exposure" language. Dose limits follow the federal values, including 150 mSv for the lens of the eye. The rules set badge placement and effective-dose formulas for staff wearing aprons, and require aprons or whole body protective barriers of at least 0.25 mm lead equivalent. No apron-inspection rule was found, and engineered protection systems are not addressed by name. Fluoroscopy must be directed by a licensed practitioner; medical radiographers may assist but limited radiographers may not. LB 912 (2026) lets nurse practitioners perform fluoroscopy after approved training.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Nebraska an NRC Agreement State?

Yes

Yes. Nebraska is an NRC Agreement State.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026
Source
nrc.gov

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Nebraska?

Yes

Title 180 NAC Chapter 6, "Diagnostic X-Rays in the Healing Arts" (amended effective 11/4/2020; fluoroscopy at § 6-005), plus 180 NAC 4, "Standards for Protection Against Radiation" (amended 6/7/2021). Chapters 1, 2, 4, 5, 6, 8, 10, 15, 16, 18 and 20 apply to X-ray registrants. Chapter 6 was read on Cornell LII because the official site did not load, so currency is uncertain.

Rule text and source
Rule
180 NAC 4; 180 NAC 6.
Source
dhhs.ne.gov
What it says
X-ray Registrants: 1, 2, 4, 5, 6, 8, 10, 15, 16, 18, & 20
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Nebraska require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes. Licensees and registrants, including X-ray/fluoroscopy registrants, must keep occupational and public doses ALARA. A radiation protection program and an annual program review are also required.

Where ALARA lives in Nebraska: Only in a rule shared with radioactive materials. ALARA appears in 180 NAC 4, which covers both radioactive-materials licensees and X-ray registrants. Chapter 6 has X-ray-specific "minimize personnel exposure" language (§ 6-003.13) but does not use the ALARA term in the sections read; §§ 6-001 and 6-002 were not read. (180 NAC 4-001.02 and 4-004.02; 180 NAC 6-003.13)

Rule text and source
Rule
180 NAC 4-004.02
Source
dhhs.ne.gov
What it says
The licensee or registrant must use, to the extent practical, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are as low as reasonably achievable (ALARA).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual whole-body dose limit in Nebraska?

Yes

50 mSv (5 rem) total effective dose equivalent per year.

Rule text and source
Rule
180 NAC 4-005.01
Source
dhhs.ne.gov
What it says
(i) The total effective dose equivalent being equal to 0.05 Sv (5 rem)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual eye-lens dose limit in Nebraska?

Yes

150 mSv (15 rem) per year. Nebraska has not adopted a lower limit such as the International Commission on Radiological Protection (ICRP)'s 20 mSv.

Rule text and source
Rule
180 NAC 4-005.01
Source
dhhs.ne.gov
What it says
A lens dose equivalent of 0.15 Sv (15 rem)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Nebraska?

Yes

500 mSv (50 rem) per year to the skin of the whole body or any extremity.

Rule text and source
Rule
180 NAC 4-005.01
Source
dhhs.ne.gov

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Nebraska?

Yes

5 mSv (0.5 rem) to the embryo/fetus of a declared pregnant woman over the whole pregnancy.

Rule text and source
Rule
180 NAC 4-012.01
Source
dhhs.ne.gov
What it says
does not exceed 5 mSv (0.5 rem)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Nebraska wear a dosimeter?

YesCheck the source

Dosimeters are required for adults likely to exceed 10% of a limit (5 mSv whole body, 15 mSv lens, 50 mSv skin or extremity); minors above 1 mSv deep, 1.5 mSv lens or 5 mSv skin; declared pregnant women likely to exceed 1 mSv; and anyone entering high or very high radiation areas. "Individuals working with medical fluoroscopic equipment" are a separate category, which may require monitoring regardless of the 10% threshold; how the regulator applies this is unclear.

Rule text and source
Rule
180 NAC 4-022.01(A)-(E)
Source
dhhs.ne.gov

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Nebraska when a protective apron is worn?

Yes

A single badge goes at the collar outside the apron. An optional second badge goes at the waist under the apron and is mandatory for declared pregnant women. The lens badge goes at the collar or nearer the eye. Effective dose is the deep dose from one collar badge; or that dose × 0.3 if the badge reads above 25% of the limit; or 1.5 × the waist reading + 0.04 × the collar reading with two badges. An NRC-approved method is also allowed.

Rule text and source
Rule
180 NAC 4-005.03(A)-(B); 4-022.01(E)(i)-(iii)
Source
dhhs.ne.gov
What it says
the sum of the deep dose equivalent reported for the individual monitoring device located at the waist under the protective apron multiplied by 1.5 and the deep dose equivalent reported for the individual monitoring device located at the neck outside the protective apron multiplied by 0.04.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Nebraska fluoroscopy rooms wear protective aprons or other apparel?

Yes

Staff and others needed for the procedure must be protected from scatter by aprons or whole body protective barriers of at least 0.25 mm lead equivalent; anyone in the useful beam needs at least 0.5 mm. Registrants must keep enough leaded aprons and gloves for all unshielded personnel. No thyroid shield or eyewear requirement was found.

Rule text and source
Rule
180 NAC 6-003.08(A)-(B); 6-003.12(F); 6-005.02(B)(ii)
Source
law.cornell.edu
What it says
(B) The x-ray operator, other staff, ancillary personnel, and other persons required for the medical procedure must be protected from the direct scatter radiation by protective aprons or whole body protective barriers of not less than 0.25 millimeter lead equivalent
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Nebraska address engineered protection systems used in place of aprons?

UnclearLess certain

Engineered radiation protection systems are not specifically addressed. However, § 6-003.08(B) allows aprons or whole body protective barriers of at least 0.25 mm lead equivalent, so on its face a whole-body barrier can stand in for an apron; whether a given engineered system qualifies is undefined. No Nebraska bill or rule on this was found.

Rule text and source
Rule
180 NAC 6-003.08(B); 6-005.02(B)
Source
law.cornell.edu
What it says
The radiation has passed through not less than 0.25 millimeter lead equivalent material including, but not limited to, drapes, bucky-slot cover panel, or self-supporting curtains. This requirement is in addition to any lead equivalency provided by the protective apron specified in 180 NAC 003.08.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Nebraska?

YesCheck the source

Fluoroscopy must be directed by a licensed practitioner, and only a licensed practitioner may perform interpretative procedures. Medical radiographers may use fluoroscopy but not perform interpretative procedures, and may work with CRNAs and (since about July 2026) nurse practitioners. Limited radiographers may not use fluoroscopy. CRNAs may use fluoroscopy with a licensed medical radiographer. NPs may perform fluoroscopy after approved training under LB 912. Physician assistants: not found.

Rule text and source
Rule
180 NAC 6-003.01, 6-003.05, 6-005.04; Neb. Rev. Stat. §§ 38-1915, 38-1916, 38-711, 38-2315(5)
Source
law.cornell.edu

Why this matters, in ORSIF's FAQs

What training or credentials does Nebraska require to operate fluoroscopy equipment?

In partLess certain

Medical radiographers must complete a board-approved program and exam; American Registry of Radiologic Technologists (ARRT) registration counts as proof. All operators must be competent in the unit's standard operating procedures and know the written safety procedures. CRNA training is set by 180 NAC 23 (text not retrieved). NPs need jointly approved training; a proposed 180 NAC 25 (4 hours of classroom training, 5 supervised procedures, 1 hour of continuing education (CE) per renewal) has not been shown to be adopted. No physician fluoroscopy training requirement was found.

Rule text and source
Rule
Neb. Rev. Stat. §§ 38-1915(2)-(3), 38-2315(5); 180 NAC 6-005.04(D), 6-003.07; 180 NAC 23
Source
nebraskalegislature.gov
What it says
(3) Presentation of proof of registration in radiography with the American Registry of Radiologic Technologists is proof of meeting the requirements of subdivisions (2)(a) and (c) of this section.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • BillLB 912 (2026)

    Enacted; approved by the Governor April 14, 2026

    Amends § 38-1915 to let radiographers use fluoroscopy with nurse practitioners, and § 38-2315(5) to allow NP fluoroscopy after approved training. Incorporated LB 936 via AM2578. Operative three calendar months after the April 17, 2026 adjournment (about July 17, 2026, by this research's calculation).

    Source: nebraskalegislature.gov

  • OtherProposed 180 NAC 25 (NP fluoroscopy training)

    Proposed in the 2025 credentialing review; rulemaking status not found (Sep 5, 2025)

    Would require at least 4 hours of post-graduate classroom training, at least 5 supervised procedures, and 1 hour of CE per renewal, with the UNMC course or an equivalent as the approved program.

    Source: dhhs.ne.gov

1 other item the research logged (radiation therapy, industrial machines, fees and other subjects)
  • BillLB 936 (2026)

    Indefinitely postponed after being folded into LB 912 (Apr 17, 2026)

    Its provisions were incorporated into LB 912.

    Source: nebraskalegislature.gov

Also worth knowing

  • Under-table scatter must be blocked by at least 0.25 mm lead equivalent.
  • Above-table scatter shielding of at least 0.25 mm lead equivalent is required in addition to aprons unless the person is 120 cm from the beam center; where a sterile field prevents it, shielding must be kept up "to the degree possible."
  • Typical and maximum air kerma rates must be measured annually and after relevant maintenance.
  • Fluoroscopy may not be used to position patients for general radiography.
  • Fluoroscopy time, number of images and operator name must be recorded for each exam.
  • New or modified installations need a shielding plan review (§ 6-003.19).
  • "Individuals working with medical fluoroscopic equipment" are listed as a separate monitoring category in § 4-022.01(E).

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Verify Chapters 4 and 6 against the official Secretary of State site or the Office of Radiological Health; the Chapter 8 title mismatch suggests revisions.
  • Does § 4-022.01(E) require monitoring of all fluoroscopy workers regardless of the 10% threshold?
  • Chapter 6 scope and definitions (§§ 6-001, 6-002), including any definition of "whole body protective barrier," were not reviewed.
  • DHHS Regulatory Guide 6.2 may cover apron inspection, thyroid and eye protection, and badge practice.
  • The text of 180 NAC 23 (CRNA training) was not retrieved.
  • Physician assistant authority, physician training, and radiographer CE (172 NAC 93) were not found.
  • Rulemaking status of the proposed 180 NAC 25 (NP training) is unknown.
  • Does DHHS plan changes to 180 NAC 4-004.02 in response to the NRC's ALARA/graded-approach rule?

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 2 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 5 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ICRP
International Commission on Radiological Protection
ARRT
American Registry of Radiologic Technologists
CE
Continuing education
All 20 sources the research read

Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.