Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Bureau of Radiological Health, Iowa Department of Health and Human Services (Iowa HHS) as the agency that regulates X-ray and fluoroscopy equipment in Iowa. Iowa is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Iowa replaced its radiation rules under Executive Order 10, effective 7/1/26, with Chapter 37 effective 7/29/26. The binding ALARA duty for X-ray registrants is in shared Chapter 37.11, which is consistent with 10 CFR Part 20. Dose limits follow the federal model, including a 150 mSv lens limit. All fluoroscopy workers must be badged. Aprons of at least 0.25 mm lead equivalent are required in interventional rooms and must be inspected annually. Apron alternatives are not addressed. Technologists need an American Registry of Radiologic Technologists (ARRT)-based permit and direct supervision for fluoroscopy; ARNPs may supervise after a course.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Iowa an NRC Agreement State?

Yes

Yes. Iowa has been an NRC Agreement State since January 1, 1986.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; 641-39.3 (Iowa Admin. Code, Ch. 39, effective 7/1/26)
Source
nrc.gov
legis.iowa.gov
What it says
The state of Iowa is an agreement state as of January 1, 1986.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Iowa?

YesCheck the source

641-Chapter 40 (ARC 0180D, effective 7/1/26) covers X-ray and fluoroscopy, with fluoroscopy in rule 40.6. General protection standards are in 641-37.11 (ARC 0387D, effective 7/29/26). Related chapters are 38 (operator permits), 39 (radioactive materials) and 42 (therapy and analytical machines). Pre-July 2026 numbering (Chapters 40/41) is out of date.

Rule text and source
Rule
641-40.3(2)"d"; 641-37.11
Source
legis.iowa.gov

Why this matters, in ORSIF's FAQs

Does Iowa require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes, binding on registrants under 37.11(2)"b". 37.1(7) uses weaker 'should be made' wording, and ALARA is defined in 37.2.

Where ALARA lives in Iowa: In a shared rule and in X-ray-specific language. The binding occupational ALARA duty is in shared Chapter 37 (37.11(2)"b"), which applies to registrants and licensees and is consistent with 10 CFR Parts 19/20. Materials licensees also follow Part 20 by reference as amended to August 1, 2025. Chapter 40 mentions ALARA only for patient shielding (40.4(9)"b") and for staff not wearing aprons (40.6(14)"d"). (641-37.11 (introduction); 641-39.5(1); 641-40.6(14)"d")

Rule text and source
Rule
641-37.11(2)"b"; 641-37.1(7)
Source
legis.iowa.gov
What it says
The licensee or registrant shall use, to the extent practical, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are ALARA.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual whole-body dose limit in Iowa?

Yes

TEDE of 5 rem (50 mSv) per year. Deep dose plus committed dose to any single organ other than the lens is limited to 50 rem (500 mSv). Minors are limited to 10% of adult limits.

Rule text and source
Rule
641-37.11(3)"a"
Source
legis.iowa.gov
What it says
The total effective dose equivalent being equal to 5 rem (0.05 Sv)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual eye-lens dose limit in Iowa?

Yes

15 rem (150 mSv) per year. Iowa has not adopted a lower lens limit.

Rule text and source
Rule
641-37.11(3)"a"
Source
legis.iowa.gov
What it says
A lens dose equivalent of 15 rem (0.15 Sv), and
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Iowa?

Yes

Shallow dose equivalent of 50 rem (500 mSv) per year to the skin or any extremity.

Rule text and source
Rule
641-37.11(3)"a"
Source
legis.iowa.gov
What it says
A shallow dose equivalent of 50 rem (0.5 Sv) to the skin of the whole body or to the skin of any extremity.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Iowa?

Yes

0.5 rem (5 mSv) to the embryo/fetus of a declared pregnant worker over the whole pregnancy.

Rule text and source
Rule
641-37.11(10)
Source
legis.iowa.gov
What it says
does not exceed 0.5 rem (5 mSv).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Iowa wear a dosimeter?

YesCheck the source

Adults likely to exceed 10% of a limit in a year must be monitored. All individuals working with medical fluoroscopic equipment must be monitored regardless of expected dose. Declared pregnant workers likely to exceed 0.1 rem (1 mSv) must be monitored. Dosimeters must be processed by a National Voluntary Laboratory Accreditation Program (NVLAP)-accredited processor.

Rule text and source
Rule
641-37.11(14)"a"(1), (4), (5)
Source
legis.iowa.gov

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Iowa when a protective apron is worn?

In partLess certain

Eye-dose badge goes at the collar outside the apron, or at an unshielded spot closer to the eye. Fetal badge goes at the waist under the apron. Extremity badge goes on the highest-dose extremity. Badges under protective clothing follow National Council on Radiation Protection and Measurements (NCRP) Report No. 57, Chapter 4. Deep dose must be used for effective dose equivalent (EDE) unless a department-approved method is used, but no named approved method was found.

Rule text and source
Rule
641-37.11(14)"c"(1)-(3); 641-37.11(3)"c"; 641-40.4(13)"a"
Source
legis.iowa.gov
What it says
An individual monitoring device used for monitoring the eye dose equivalent, to demonstrate compliance with subrule 37.11(3) shall be located at the neck (collar), outside any protective apron being worn by the monitored individual or at an unshielded location closer to the eye;
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Iowa fluoroscopy rooms wear protective aprons or other apparel?

Yes

Aprons of at least 0.25 mm lead equivalent must be worn by all except the patient in interventional/special-procedure rooms (brief occupants may skip them if badge reports confirm low exposure) and in sterile-field cases. Barriers with viewing panels of at least 0.5 mm must be available. Ancillary shielding must be used on stationary systems, and sufficient apparel must be kept on hand. No rule requires wearing thyroid shields or eyewear.

Rule text and source
Rule
641-40.6(12), 40.6(14), 40.4(9)
Source
legis.iowa.gov
What it says
Protective aprons of not less than 0.25 mm of lead equivalent shall be worn in the fluoroscopy room by all individuals (except the patient).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Iowa require protective aprons to be inspected?

Yes

Yes. All protective apparel and auxiliary shields must be evaluated annually for integrity and labeled with their lead equivalent. The method is not specified.

Rule text and source
Rule
641-40.4(9)"a"
Source
legis.iowa.gov
What it says
All protective apparel and auxiliary shields shall be evaluated annually for integrity and clearly labeled with lead equivalent.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Iowa address engineered protection systems used in place of aprons?

Not found

Not addressed. No rule covers engineered systems replacing aprons. Ancillary shielding is supplemental and aprons are still required. 40.4(8)"b"(3) allows whole body barriers but is framed around radiographic exposure. Waivers and exemptions exist but are not specific to this technology.

Rule text and source
Rule
641-40.4(8)"b"(3); 641-40.6(12)"a"
Source
legis.iowa.gov
What it says
For stationary fluoroscopic systems, ancillary shielding, such as drapes, self-supporting curtains, or viewing shields, shall be available and used as supplemental protection for all individuals other than the patient in the room during a fluoroscopy procedure.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Iowa?

UnclearLess certain

An Iowa permit is required, except for physicians, PAs, chiropractors, dentists, hygienists, podiatrists, certified dental radiographers and students. Limited permit holders may not perform fluoroscopy. Technologists and students need direct supervision by a licensed practitioner, radiologist assistant or ARNP. ARNPs may supervise after a course, but it is unclear whether they may operate. A licensed practitioner must interpret all images.

Rule text and source
Rule
641-38.2(1), 38.3, 40.6(13)"c", 40.6(15); 481-621.4(5)
Source
legis.iowa.gov
What it says
The use of fluoroscopy by radiologic technologists and radiologic students shall be performed under the direct supervision of a licensed practitioner, a radiologist assistant or an ARNP, pursuant to 481-subrule 621.4(5)
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Iowa require to operate fluoroscopy equipment?

Yes

Technologist permit requires passing the ARRT radiography exam and 24 continuing education (CE) hours every two years. Radiologist assistants need formal education, one year as a technologist, the ARRT RA exam and 50 CE hours. All fluoroscopy operators need qualified-expert training in eight topics and competence in dose-saving features. Supervising ARNPs need a course. There is no separate fluoroscopy permit, set hour count or physician-specific requirement.

Rule text and source
Rule
641-38.4, 38.6, 40.6(13)"c"; 481-621.4(5)
Source
legis.iowa.gov
What it says
Submit proof of a passing score on the ARRT general radiography examination, the NMTCB nuclear medicine examination, or the ARRT radiation therapist examination.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Adopted ruleChapter 37 General Provisions for Radiation and Radiation Protection Standards (ARC 0387D)

    Adopted; effective July 29, 2026

    Proposed as ARC 9772C (11/26/25), amended as ARC 0223D (4/29/26), adopted in IAB 6/24/26 with no comments and no changes.

    Source: legis.iowa.gov

1 other item the research logged (radiation therapy, industrial machines, fees and other subjects)
  • Adopted ruleChapters 38-42 rewrite under Executive Order 10 (ARC 0288D, 0179D, 0180D, 0181D, 0182D)

    Adopted; effective July 1, 2026

    Full Red Tape Review replacement of Chapters 38-42; the new chapters carry a rescission date of 7/1/31.

Also worth knowing

  • Every fluoroscopy worker must wear a dosimeter, not only those above 10% of a limit.
  • A dose-area-product monitor is required on interventional and special-procedure units (40.6(16)).
  • Facilities need a written patient-dose policy following ACR-AAPM guidance or NCRP Report 168, and field size must be kept minimal under sterile-field conditions.
  • A qualified expert must test fluoroscopy equipment at least every 12 months (40.6(6)).
  • Outdated cross-references: 37.11(2)"d" points to 40.4(9)"b", now a patient-shielding provision; 481-621.4(5) points to 641-38.2, now the exemptions rule.
  • There was a gap of about four weeks between the Chapter 40 effective date (7/1/26) and the Chapter 37 effective date (7/29/26).
  • Iowa has not adopted a lower lens limit; it remains 150 mSv per year.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Pending changes after June 2026 (bulletins July-November 2026 and 2026 bills) could not be checked.
  • Whether Iowa HHS commented on the NRC ALARA proposal or plans to change 37.11 or update the Chapter 39 reference date.
  • Which dosimetry method is department-approved under 37.11(3)"c".
  • Whether ARNPs or other unlisted clinicians may operate fluoroscopy, and how to read "and" in 40.6(13)"c".
  • Why the general technologist definition omits fluoroscopy although 40.6(15) assumes technologists perform it.
  • How the bureau treated occupational standards for X-ray registrants during the July 1-28, 2026 gap.

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 2 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 4 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
NCRP
National Council on Radiation Protection and Measurements
TEDE
Total effective dose equivalent
EDE
Effective dose equivalent
ARRT
American Registry of Radiologic Technologists
NVLAP
National Voluntary Laboratory Accreditation Program
CE
Continuing education
All 13 sources the research read

Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.