The Evidence
Resources
Clinician AssessmentGet Your Risk Score FAQs Admin ToolkitMembers Economic Impact Research ArticlesMembers SIRP 2025 WebinarMembers Videos
Guidelines
What is ALARA+? US Guidelines International Guidelines News Is Not Here About Contact Donate
Join Free

Please double-check this information. This is an ORSIF research summary, researched November 3, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Illinois Emergency Management Agency and Office of Homeland Security (IEMA-OHS), Nuclear & Radiation Safety program as the agency that regulates X-ray and fluoroscopy equipment in Illinois. Illinois is a U.S. Nuclear Regulatory Commission (NRC) Agreement State: it has signed an agreement with the NRC to regulate certain radioactive materials itself.

Illinois's ALARA requirement is in its general radiation protection rule, 32 Ill. Adm. Code 340.110(b), which applies to both licensees and X-ray registrants. The X-ray rule (Part 360) asks for procedures to minimize patient and occupational doses without ALARA wording. Occupational limits are 50 mSv per year whole body and 150 mSv per year to the lens of the eye, with no lower eye limit. Fluoroscopy staff must be protected by aprons of at least 0.25 mm lead equivalent, by barriers or by distance, and everyone except the patient in a cardiac cath lab must wear an apron. A proposed ERPS rule published March 13, 2026 was paused on October 22, 2026. Only licensed physicians, dentists and podiatrists may run fluoroscopy on their own, with limited supervised exceptions for accredited radiographers, radiation therapists and radiologist assistants.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Is Illinois an NRC Agreement State?

Yes

Yes. Illinois is on the NRC's list of Agreement States, updated October 29, 2026.

Rule text and source
Rule
NRC list of Agreement States, updated October 29, 2026; 32 Ill. Adm. Code 340.520(b) (incorporates 10 CFR 20 Appendix B)
Source
nrc.gov
issrt.org
nrc.gov
What it says
the agency is working closely with the NRC to draft a replacement bill.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Which rules cover X-ray and fluoroscopy equipment in Illinois?

Yes

The X-ray and fluoroscopy rule is 32 Ill. Adm. Code 360, "Use of X-Rays in the Healing Arts Including Medical, Dental, Podiatry, and Veterinary Medicine." Fluoroscopy is in Section 360.50. Part 360 was last amended effective May 29, 2014 (38 Ill. Reg. 12031), and Section 360.50 effective February 29, 2008 (32 Ill. Reg. 3693). Part 360 applies in addition to Parts 310, 320, 340, 400 and 410. General standards are in Part 340, and operator accreditation is in Part 401.

Rule text and source
Rule
32 Ill. Adm. Code 360.10(a); 340.10(a)
Source
ilga.gov
ilga.gov
ilga.gov
What it says
The provisions of this Part are in addition to, and not in substitution for, other applicable provisions of 32 Ill. Adm. Code 310, 320, 340, 400 and 410.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Illinois require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes. 340.110(b) applies to each licensee or registrant, and X-ray machine users are registrants. The annual program review in 340.110(c) applies only to licensees; registrants must review their program at least once per inspection cycle (340.110(e)).

Where ALARA lives in Illinois: In a shared rule and in X-ray-specific language. The explicit ALARA requirement is only in the shared rule, Part 340, which covers both licensees and registrants. The X-ray rule, Part 360 (Section 360.30), requires "procedures to minimize patient and occupational doses" but does not use ALARA wording. An NRC-driven change to Part 340 would apply to X-ray registrants unless Illinois limits it to licensees. (32 Ill. Adm. Code 340.110(b); 360.30)

Rule text and source
Rule
32 Ill. Adm. Code 340.110(b), (e)
Source
ilga.gov
regulations.justia.com
What it says
The licensee or registrant shall use, to the extent practicable, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and public doses that are as low as is reasonably achievable (ALARA).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual eye-lens dose limit in Illinois?

Yes

0.15 Sv (15 rem), or 150 mSv per year. No lower lens limit has been adopted.

Rule text and source
Rule
32 Ill. Adm. Code 340.210(a)(1)-(2)
Source
ilga.gov
What it says
A) A lens dose equivalent of 0.15 Sv (15 rem); and B) A shallow dose equivalent of 0.5 Sv
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Illinois?

Yes

0.5 Sv (50 rem), or 500 mSv per year, for the skin or any extremity.

Rule text and source
Rule
32 Ill. Adm. Code 340.210(a)(1)-(2)
Source
ilga.gov
What it says
A) A lens dose equivalent of 0.15 Sv (15 rem); and B) A shallow dose equivalent of 0.5 Sv
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Illinois?

Not foundCheck the source

not found. The only related figure found is the monitoring trigger for declared pregnant women: a deep dose above 1 mSv (0.1 rem) during the pregnancy.

Rule text and source

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Illinois wear a dosimeter?

Yes

Individual dosimeters must be provided and used for adults likely to receive more than 10% of the 340.210(a) limits in a year, minors likely to receive more than 10% of their limits, declared pregnant women likely to receive a deep dose above 1 mSv (0.1 rem) during the pregnancy, and anyone entering a high or very high radiation area. Section 360.30 applies these monitoring rules to everyone associated with X-ray operation.

Rule text and source
Rule
32 Ill. Adm. Code 340.520(a)
Source
regulations.justia.com
What it says
Adults likely to receive, in 1 year from sources external to the body, a dose in excess of 10 percent of the limits in Section 340.210(a);
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Illinois when a protective apron is worn?

Not foundCheck the source

not found. No badge location, two-badge method or effective-dose method was found. 340.210(d) allows doses to be estimated from surveys if the dosimeter was not in the region of highest exposure.

Rule text and source
Rule
32 Ill. Adm. Code 340.210(d)
Source
law.cornell.edu
What it says
may be assessed from surveys or other radiation measurements for the purpose of demonstrating compliance with the occupational dose limits, if the individual monitoring device was not in the region of highest potential exposure
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Illinois fluoroscopy rooms wear protective aprons or other apparel?

Yes

In general fluoroscopy, the operator, assistants and observers must be protected by aprons of at least 0.25 mm lead equivalent, by whole-body barriers, or by sufficient distance. A shield of at least 0.25 mm lead equivalent must be provided and used but does not replace the apron. In stationary cardiac cath rooms, aprons are mandatory for everyone except the patient, and any viewing panel must be at least 0.5 mm lead equivalent. No thyroid shield or eyewear requirement was found.

Rule text and source
Rule
32 Ill. Adm. Code 360.50(i), (j), (k)
Source
ilga.gov
What it says
Protective aprons of not less than 0.25 millimeter of lead equivalent shall be worn in the fluoroscopy room by all individuals (except the patient).
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Does Illinois require protective aprons to be inspected?

Not foundLess certain

not found. Section 360.30 requires written procedures on the use of personnel and patient protective devices, but no inspection interval or method was found.

Rule text and source
Rule
32 Ill. Adm. Code 360.30 (procedures list)
Source
regulations.justia.com
What it says
Use of personnel and patient protective devices;
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Do the rules in Illinois address engineered protection systems used in place of aprons?

In part

Current rules allow whole-body barriers or distance instead of aprons in general fluoroscopy, but shields do not replace aprons and aprons are required for everyone in stationary cardiac cath rooms. A proposed rule (50 Ill. Reg. 3961, published March 13, 2026) would authorize Enhanced Radiation Protection Systems as an alternative to lead aprons. It was paused on October 22, 2026.

Rule text and source
Rule
32 Ill. Adm. Code 360.50(j)(2); proposed amendments, 50 Ill. Reg. 3961
Source
ilga.gov
iemaohs.illinois.gov
ilsos.gov
What it says
This shielding shall not be a substitute for the wearing of a protective apron (0.25 millimeter lead equivalent) for protection against scattered radiation.
This quote was matched word for word to the source page.

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Illinois?

Yes

Only those licensed under the Medical Practice Act, Dental Practice Act or Podiatric Medical Practice Act may operate fluoroscopy on people, with four exceptions: accredited medical radiographers for static functions needing no diagnostic interpretation, under supervision; accredited radiographers under the direct supervision of a licensed practitioner who is physically present and participating; accredited radiographers or radiation therapists for therapy simulation, under supervision; and accredited radiologist assistants under the supervision of an ABR- or AOBR-certified practitioner. Physician assistants and nurse practitioners are not listed.

Rule text and source
Rule
32 Ill. Adm. Code 360.50(n); 77 Ill. Adm. Code 250.630(d)
Source
ilga.gov
ilga.gov
What it says
No person shall intentionally administer radiation to a human being with a fluoroscopic radiation machine unless such person is licensed to practice a treatment of human ailments under the Medical Practice Act of 1987
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

What training or credentials does Illinois require to operate fluoroscopy equipment?

In partLess certain

Non-physician operators must hold IEMA-OHS accreditation under Part 401 as a medical radiographer, radiation therapist or radiologist assistant, which includes examination and renewal requirements. The hospital rule requires accredited staff to take continuing education. All operators must be instructed in, and show competence with, the registrant's operating and safety procedures. No fluoroscopy-specific training requirement for physicians was found.

Rule text and source
Rule
32 Ill. Adm. Code 360.30; 401.20; 401.70; 77 Ill. Adm. Code 250.630(e)
Source
law.cornell.edu
law.cornell.edu
What it says
Individuals who operate radiation machines shall be instructed in and able to demonstrate competence with the registrant's operating and safety procedures.
This quote was matched word for word to the source page.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

  • Proposed ruleERPS amendments to Part 360 (360.20 and 360.50)

    Paused on October 22, 2026, at second notice, to incorporate forthcoming Conference of Radiation Control Program Directors (CRCPD) guidance (Mar 13, 2026)

    Would authorize Enhanced Radiation Protection Systems during fluoroscopically guided procedures as an alternative to lead aprons (IEMA's page describes the scope as cardiac catheterization). Published at 50 Ill. Reg. 3961. The American Society of Echocardiography filed supporting comments on April 8, 2026.

    Source: iemaohs.illinois.gov

  • BillHB3744

    Signed August 15, 2025; effective January 1, 2026

    Deals with nuclear fuel shipments and stray radiation sources, not fluoroscopy.

  • BillHR0565 (104th General Assembly)

    Status not determined

    House resolution urging IEMA-OHS to amend Part 360 to create a pathway for ERPS.

    Source: ilga.gov

  • OtherRadiation Protection Act sunset

    Act expires January 1, 2027; whether an extension passed is not confirmed

    The GOMB study (May 8, 2026) reports that IEMA-OHS made no recommendations to change the Act and that rulemakings for Part 360 (fluoroscopy) and Part 370 (mammography) are under way.

    Source: budget.illinois.gov

Also worth knowing

  • 360.50(i) accepts barriers or distance instead of aprons in general fluoroscopy, while 360.50(k)(2) requires aprons in stationary cardiac cath rooms. An agency note in (k) recommends that staff step back behind barriers during exposures.
  • 360.50(i) and 360.40 measure "sufficient distance" against the limits in 340.310, which the codification index titles "Dose Limits for Individual Members of the Public," not the occupational limits.
  • Registrants must give monitored workers an annual dose report if their dose exceeds 1 mSv (100 mrem).
  • Workers or their representatives may ask IEMA for an inspection if they believe there is a violation or unnecessary exposure (Part 400).
  • Fluoroscopes need a 5-minute cumulative timer and an audible signal when high-level control is used.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • Agreement State status: not confirmed directly. Check the NRC's Agreement State program list and IEMA-OHS's "About" page.
  • Embryo/fetus dose limit: not retrieved. Read the full official text of Part 340, Subpart C (https://iemaohs.illinois.gov/laws/regs-title32.html).
  • Badge placement and effective-dose methods: check 340.1160 and the rest of Subpart F, plus IEMA X-ray guidance (https://iemaohs.illinois.gov/nrs/forms.html).
  • Full text of 360.30 and 360.40, to confirm whether there are apron inspection, thyroid shield or eyewear provisions.
  • The proposed ERPS rule text (50 Ill. Reg. 3961): which procedures it covers, its performance criteria (HR0565 mentions 0.5 mm lead equivalent), its monitoring conditions, and whether the one-year first-notice window leaves time to file a second notice after the pause.
  • Radiation Protection Act sunset: whether an extension bill passed in 2026 before the January 1, 2027 expiry.
  • Status of HR0565.
  • Effective date of the 2023 Part 340 amendments (47 Ill. Reg. 9163), and whether Illinois has begun any rulemaking on the NRC's proposed ALARA change.
  • The 340.310 cross-reference: confirm what limit 360.50(i) and 360.40 actually point to.
  • Physician training: whether IDFPR medical licensing rules or hospital credentialing impose fluoroscopy training, and whether American Registry of Radiologic Technologists (ARRT) certification satisfies 401.70.

Who regulates, and where to read the rules

Documents ORSIF has on file

Copies saved earlier. Rules change, so check the current text at the source.

  • Emergency Management Agency Regs (NRC Archive) Download

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 3 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 4 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
TEDE
Total effective dose equivalent
ARRT
American Registry of Radiologic Technologists
CRCPD
Conference of Radiation Control Program Directors
All 25 sources the research read