Please double-check this information. This is an ORSIF research summary, researched November 3, 2026, with its weakest answers rechecked November 5, 2026. It is not comprehensive and not always accurate: rules change, and answers may be incomplete, out of date or wrong. It is education, not legal advice. Not yet reviewed by a regulatory expert. Confirm each requirement at the source linked beside the answer, with the state program and with your facility's radiation safety officer. How this was made

In brief

ORSIF's research identified the Idaho Department of Health and Welfare (DHW), Idaho Radiation Control Program, Bureau of Laboratories, Division of Public Health as the agency that regulates X-ray and fluoroscopy equipment in Idaho. Idaho is not a U.S. Nuclear Regulatory Commission (NRC) Agreement State, so the NRC regulates radioactive materials there directly. The state still regulates X-ray machines. Its 1968 agreement ended in 1991.

Idaho's rewritten X-ray rule, IDAPA 16.02.27 (effective 1 July 2026), removed all incorporation by reference, including the Conference of Radiation Control Program Directors (CRCPD) model dose limits and fluoroscopy rules, and Idaho is not an NRC Agreement State. The rule requires exposure "as low as is practical" but has no numeric dose limits, no dosimetry threshold, and no rules on aprons, apron inspection, or apron alternatives. For private-sector workers, federal Occupational Safety and Health Administration (OSHA) 29 CFR 1910.1096 limits whole-body dose, including the lens of the eye, to 1.25 rem (12.5 mSv) per quarter, sets higher limits for the hands, feet and skin, and requires dosimeters above 25 percent of a limit, but it does not cover state and local government workers and sets no limit for a declared pregnant worker. Anyone trained in 11 radiation-safety topics may operate X-ray equipment, including fluoroscopy, and Idaho does not license technologists.

The rules, question by question

Every answer names the rule it comes from. Open "Rule text and source" to read the citation, the source page and, where it could be matched, the exact wording.

Where the rules live

Which rules apply, and whether ALARA is among them.

Which rules cover X-ray and fluoroscopy equipment in Idaho?

Yes

IDAPA 16.02.27, "Idaho Radiation Control Rules," sections 000-010, effective 7-1-26, is an X-ray-only rule. The 2026 rewrite (Docket 16-0227-2501) removed the adopted CRCPD model Parts D and F. The official PDF's cover page still refers to incorporation under Section 004, but the rule body governs. Statute: Idaho Code §§ 56-1041 to 56-1053.

Rule text and source
Rule
IDAPA 16.02.27.001 (Scope).
Source
adminrules.idaho.gov
What it says
To define licensure, education, quality assurance, and safety requirements for X-ray machines.
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

Does Idaho require X-ray users to keep doses as low as reasonably achievable (ALARA)?

Yes

Yes, in different words. Licensed facilities must keep radiation exposure "as low as is practical." The phrase is undefined, and the rule does not say whether it covers worker dose, patient dose, or both.

Where ALARA lives in Idaho: In X-ray-specific rules. ALARA-type language appears only in the X-ray-only rule IDAPA 16.02.27. Idaho has no state radioactive-materials program or shared rule, is not an Agreement State, and removed all incorporation by reference, so an NRC change would not reach it directly. (IDAPA 16.02.27.009.01.b; Senate Health & Welfare Committee minutes, 19 January 2026.)

Rule text and source
Rule
IDAPA 16.02.27.009.01.b.
Source
adminrules.idaho.gov
What it says
Licensed facilities must: … b. Keep radiation exposure as low as is practical;
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

Dose limits

The annual limits for workers, written in millisieverts (mSv). Ten mSv equal one rem.

What is the annual whole-body dose limit in Idaho?

In part

Idaho's X-ray rule sets no numeric dose limit and only requires facilities to keep exposure as low as is practical. For private-sector employers, federal OSHA limits whole-body dose to 1.25 rem (12.5 mSv) per calendar quarter, or up to 3 rem (30 mSv) per quarter if lifetime dose stays within 5 rem (50 mSv) times the worker's age minus 18 and records are kept. State and local government workers are not covered by federal OSHA.

Rule text and source
Rule
29 CFR 1910.1096(b)(1) Table G-18 and (b)(2)(i)
Source
osha.gov
What it says
During any calendar quarter the dose to the whole body shall not exceed 3 rems; and
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

What is the annual eye-lens dose limit in Idaho?

In part

Idaho's rule sets no lens of the eye limit. For private-sector employers, federal OSHA counts the lens of the eye as part of the whole body, so the same limit applies: 1.25 rem (12.5 mSv) per calendar quarter, or up to 3 rem (30 mSv) per quarter under lifetime-dose conditions. Neither Idaho nor OSHA has adopted the International Commission on Radiological Protection (ICRP)'s 20 mSv figure.

Rule text and source
Rule
29 CFR 1910.1096(b)(1) Table G-18 and (b)(2)(iii)
Source
law.cornell.edu
What it says
As used in this subparagraph Dose to the whole body shall be deemed to include any dose to the whole body, gonad, active bloodforming organs, head and trunk, or lens of the eye.
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

What is the annual limit for the skin, hands and feet in Idaho?

In part

Idaho's rule sets no skin or extremity limit. For private-sector employers, federal OSHA limits dose to the hands, forearms, feet and ankles to 18.75 rem (187.5 mSv) per calendar quarter, and dose to the skin of the whole body to 7.5 rem (75 mSv) per quarter.

Rule text and source
Rule
29 CFR 1910.1096(b)(1), Table G-18
Source
osha.gov
What it says
shall possess, use, or transfer sources of ionizing radiation in such a manner as to cause any individual in a restricted area to receive in any period of one calendar quarter from sources in the employer's possession or control a dose in excess of the limits specified in Table G-18
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

What limit applies to a declared pregnant worker in Idaho?

NoLess certain

Neither Idaho's X-ray rule nor the federal OSHA radiation standard sets a dose limit for the embryo or fetus of a declared pregnant worker. Idaho's rule only requires facilities to keep radiation exposure as low as is practical.

Rule text and source
Rule
IDAPA 16.02.27.000 to.010 (7-1-26); 29 CFR 1910.1096
Source
adminrules.idaho.gov

Why this matters, in ORSIF's FAQs

Dosimeters

When a worker must wear a dosimeter, and where.

When must a worker in Idaho wear a dosimeter?

In partLess certain

Idaho's rule sets no numeric threshold and only requires facilities to ensure personnel wear monitoring devices "if applicable." For private-sector workers covered by federal OSHA, employers must supply and require dosimeters for anyone likely to receive more than 25 percent of the applicable dose limit in a calendar quarter (5 percent for workers under 18).

Rule text and source
Rule
29 CFR 1910.1096(d)(2)(i)
Source
law.cornell.edu
What it says
Each employee who enters a restricted area under such circumstances that he receives, or is likely to receive, a dose in any calendar quarter in excess of 25 percent of the applicable value specified in paragraph (b)(1) of this section
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

Where must the dosimeter be worn in Idaho when a protective apron is worn?

NoLess certain

Idaho's rule only says facilities must make sure staff wear monitoring devices if applicable, and that operator training covers the use of personnel monitoring equipment. It says nothing about where to wear a badge with an apron, two-badge methods or how to estimate effective dose.

Rule text and source
Rule
IDAPA 16.02.27.009.01.g and 009.02.i (7-1-26)
Source
adminrules.idaho.gov

Why this matters, in ORSIF's FAQs

Aprons and alternatives

Protective apparel, how it is checked, and whether other systems are addressed.

Must staff in Idaho fluoroscopy rooms wear protective aprons or other apparel?

NoLess certain

Idaho's rule does not require protective aprons, thyroid shields or protective eyewear, and sets no lead equivalence. Operator training must cover controlling dose through time, distance and shielding, but there is no requirement to wear protective garments.

Rule text and source
Rule
IDAPA 16.02.27.000 to.010, including 009.02.f (7-1-26)
Source
adminrules.idaho.gov

Why this matters, in ORSIF's FAQs

Does Idaho require protective aprons to be inspected?

NoLess certain

Idaho's rule has no requirement to inspect protective aprons or garments. Its quality control section covers only following the X-ray machine manufacturer's quality control procedures and keeping a written quality assurance plan.

Rule text and source
Rule
IDAPA 16.02.27.007 (7-1-26)
Source
adminrules.idaho.gov

Why this matters, in ORSIF's FAQs

Do the rules in Idaho address engineered protection systems used in place of aprons?

NoLess certain

Idaho's rule does not address engineered shielding systems used in place of personal protective garments. It requires a qualified expert to prepare a shielding plan for the room, and requires training on time, distance and shielding, but it says nothing about replacing aprons.

Rule text and source
Rule
IDAPA 16.02.27.005 and 009.02.f (7-1-26)
Source
adminrules.idaho.gov

About ALARA+

Who operates the equipment

Who may use fluoroscopy equipment and what training the rules ask for.

Who may operate fluoroscopy equipment in Idaho?

Yes

Any individual may operate X-ray equipment, including fluoroscopy, after completing facility training and proving competency in radiation safety. There is no profession or supervision restriction, and Idaho does not license radiologic technologists. One commercial source conflicts on licensure, but no supporting statute was found.

Rule text and source
Rule
IDAPA 16.02.27.009.02.
Source
adminrules.idaho.gov
What it says
No individual will be permitted to operate an X-ray machine until they have completed training and proven competency in radiation safety topics.
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

What training or credentials does Idaho require to operate fluoroscopy equipment?

Yes

Facility-provided training in 11 listed radiation-safety topics, with records kept for at least two license renewal cycles. There is no American Registry of Radiologic Technologists (ARRT) requirement, fluoroscopy permit, minimum hours, or continuing education. DHW posts a free training course.

Rule text and source
Rule
IDAPA 16.02.27.009.02.a-k.
Source
adminrules.idaho.gov
What it says
X-ray operator training must include the following topics:
This quote was matched word for word to a page the research read.

Why this matters, in ORSIF's FAQs

Changes on the way, and recent ones

Rules, bills and guidance the research found from 2025 and 2026, with the ones that touch fluoroscopy teams first.

The research found nothing in this list that changes the rules for fluoroscopy teams.

1 other item the research logged (radiation therapy, industrial machines, fees and other subjects)
  • Adopted ruleZero-Based Regulation rewrite of IDAPA 16.02.27, Docket 16-0227-2501

    In effect 1 July 2026; approved by SCR 128 (Jul 1, 2026)

    Negotiated rulemaking notice 2 April 2025; proposed rule 4 June 2025; pending rule 6 August 2025, adopted with no changes; approved by the Senate Health & Welfare Committee 19 January 2026 and by SCR 128. Removed all incorporation by reference, including CRCPD Parts D and F.

    Source: adminrules.idaho.gov

Also worth knowing

  • Idaho is not an OSHA State Plan; federal OSHA (29 CFR 1910.1096) may cover most private-sector workers, but public-sector workers may not be covered.
  • Section 009.01.a still requires posting "notice standards for protection against radiation" although Idaho no longer has its own standards to post.
  • Federal facilities are exempt from Idaho X-ray licensing (16.02.27.003.01).
  • A shielding plan by a qualified expert must be submitted 30 days before patient imaging (005).
  • DHW may revoke a license if a device is used in a way that "endangers patients, facility staff, or the public" (010).
  • The official rule PDF's cover page is stale and still refers to incorporation under Section 004.

What ORSIF could not confirm

Questions the research could not settle. If you know the answer, tell us.

  • How does DHW decide when monitoring is "applicable," what are its dosimetry waiver criteria, and do inspectors use the old model limits as guidance?
  • Does federal OSHA enforce 29 CFR 1910.1096 against X-ray and fluoroscopy users in Idaho, and what covers public-sector workers?
  • What exactly did the removed model Part D and Part F text say?
  • Do Board of Medicine or Board of Nursing rules address fluoroscopy by physicians, PAs or NPs?
  • Will there be any 2027 bill or DHW docket on technologist licensure, apron alternatives, or restoring dose standards?

Double-check before you rely on this page

ORSIF compiled this page from the sources linked on it and did its best. It is not comprehensive and it is not always accurate. Rules change, a rule may have been missed or misread, and the sources themselves can be out of date. Treat this page as a starting point.

Where to check

What may be missing here

  • 0 of 14 answers on this page are "Not found" or "Unclear". That means ORSIF did not find the answer in the rules it reviewed, not that no rule exists.
  • 6 answers carry a flag or a lower confidence ("Check the source" or "Less certain").
  • Researched November 3, 2026. Rules may have changed since.
  • Only the state's rules for X-ray and fluoroscopy equipment were reviewed.

Found something wrong or missing? Tell ORSIF.

Sources and terms

Terms used on this page
ALARA
As low as reasonably achievable: keep radiation doses as low as is reasonable, below the legal limits.
Agreement State
A state that has signed an agreement with the U.S. Nuclear Regulatory Commission to regulate certain radioactive materials itself.
mSv
Millisievert, a unit of radiation dose. Ten mSv equal one rem, the older unit some rules still use.
Dosimeter
A badge or device worn to measure a worker's radiation dose.
Lead equivalent
The thickness of lead (mm Pb) that would give the same protection as the material described.
NRC
U.S. Nuclear Regulatory Commission
ICRP
International Commission on Radiological Protection
ARRT
American Registry of Radiologic Technologists
OSHA
Occupational Safety and Health Administration
CRCPD
Conference of Radiation Control Program Directors
All 11 sources the research read

Found something out of date or wrong? Tell ORSIF. Corrections are checked against the rule text and the page is updated.