Research summary, systematic review or meta-analysis, 2016

Radiation safety for anaesthesia providers in the orthopaedic operating room

Rhea EB, Rogers TH, Riehl JT. Anaesthesia. 2016

Read the original paper

In plain language

This systematic review found that anaesthesia providers working 1.5 m or more from standard fluoroscopy units in orthopaedic operating rooms received no or negligible measured radiation. The authors question routine lead apron use for them, but this may not apply to higher-dose interventional settings.

At a glance

Type of study
Systematic review or meta-analysis, Systematic review
Who was studied
Anesthesia staff
Summary based on
the abstract

What it found

  • At 1.5 m from the radiation source, anaesthetists received no measurable radiation or negligible amounts that would require an unreasonable number of operations to accumulate a significant dose.

    Key figures: 1.5 m

  • Doses at this distance were often at the detection limit of the dosimeters used.

  • The authors question the need for lead aprons for anaesthesia providers routinely positioned 1.5 m or more from standard fluoroscopy units.

    Key figures: ≥1.5 m

Limits to keep in mind

Abstract only, with no number of included studies or pooled dose values reported; findings are limited to standard fluoroscopy units in orthopaedic surgery and may not apply to higher-dose interventional procedures or to staff working closer than 1.5 m.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.