In plain language
In 39 fenestrated aortic repairs, dosimetry on the anesthesia equipment recorded higher doses than the operators. Staff dose tracked patient kerma-area product (KAP); shielding, fewer digital subtraction runs and avoiding lateral angulation were linked to lower measured dose.
At a glance
- Type of study
- Original research, Dosimetry measurement study
- Who was studied
- Vascular surgeons, Nurses, Radiologic technologists, Anesthesia staff, Patients
- Size
- n = 39 procedures
- Topics
- Dosimetry and monitoringDose reduction techniquesRoom shielding and protective devicesPersonal protective equipmentPatient dose
- Summary based on
- the abstract
What it found
The dosimeter on the anesthesia equipment received more radiation per case than the average operator, attributed to ineffective shielding; scrub nurse and technologist received less.
Key figures: anesthesia +143 μSv (38-247); scrub nurse -106 μSv (66-146); RT -100 μSv (55-145) vs average operator
Personnel doses correlated well with patient kerma area product but less with fluoroscopy time or cumulative air kerma.
Key figures: r = .82 operator, r = .85 scrub nurse, r = .86 anesthesia; all P < .001
During preoperative cone beam computed tomography (CT), shielding greatly reduced the technologist's dose.
Key figures: 1.1 μSv (0.6-1.5) shielded vs 37 μSv (22-53) unshielded
Operator dose rate was higher in lateral than posterior-anterior C-arm projection.
Key figures: 1.78 (1.37-2.31) times
After adjustment for lead aprons, average operator effective dose per case was low; digital subtraction acquisitions contributed a large share of doses.
Key figures: 38 μSv
Limits to keep in mind
Single procedure type (fenestrated aortic repair) with 39 cases, likely a single centre; dosimeter positions (e.g., on anesthesia equipment) may not reflect individual body doses.
Related research summaries
- Radiation Exposure To Operating Room Personnel And Patients During Endovascular Procedures (2013, Dosimetry measurement study)
- ICRP Draft - Radiological Protection in Fluoroscopically Guided Procedures (Guideline or consensus statement)
- Radiation Protection in Interventional Radiology (2022, Narrative review)
- Radiation-Induced Noncancer Risks in Interventional Cardiology: Optimisation of Procedures and Staff and Patient Dose Reduction (2013, Narrative review)
- AST Standards for Ionizing Radiation Exposure (Guideline or consensus statement)
How this summary was made
ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.
Prepared November 3, 2026.