Research summary, narrative review, 2011

Personal dosimetry for interventional operators: when and how should monitoring be done?

Martin CJ. British Journal of Radiology. 2011

Read the original paper

In plain language

A review of published dose studies produced workload-based estimates of likely eye, thyroid and hand doses for interventional radiologists and cardiologists, for use in risk assessment. It also notes that poorly placed dosimeters can give misleading readings.

At a glance

Type of study
Narrative review
Who was studied
Interventional radiologists, Interventional cardiologists
Summary based on
the abstract

What it found

  • Dose indicator values based on third-quartile values from published distributions were derived to predict orders of magnitude of operator doses to the eye, thyroid and hands from workload.

  • These dose estimates could be used in risk assessments when reviewing protection and monitoring requirements.

  • Suboptimal dosimeter placement can produce misleading dose measurements, so wearing positions should be part of risk assessments.

  • Published data on the protection offered by shielding and technique factors were also reviewed to inform risk assessments.

Limits to keep in mind

This is a literature review whose derived indicator values depend on heterogeneous published studies. The abstract gives no numbers, study counts or search methods.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.

Prepared November 3, 2026.