Research summary, original research, 2024

Intraoperative Staff Radiation Exposure During Aortic Endovascular Procedures

Clauss N, Kuntz S, Colvard B, Ohana M, Mertz L, Lejay A, et al.. Annals of vascular surgery. 2024

Read the original paper

In plain language

Across 41 aortic endovascular procedures, the main operator had the highest body, hand and leg doses, but assistant operators had higher eye lens doses, especially in complex fenestrated/branched and iliac branch repairs. Staff positioning matters even with full protective equipment.

At a glance

Type of study
Original research, Dosimetry measurement study
Who was studied
Vascular surgeons, Mixed lab staff, Patients
Size
n = 41 procedures
Summary based on
the abstract

What it found

  • The main operator received the highest radiation dose to the whole body, hands and ankles.

  • Eye lens dose was higher for the assistant operators than for the main operator.

  • Assistant operators faced a high exposure risk, mainly during fenestrated/branched endovascular aneurysm repair (EVAR) and EVAR with iliac branch.

  • Patient peak skin dose rose significantly with procedure complexity and was below the reading threshold for many standard EVAR cases.

    Key figures: 24 patients below reading threshold

  • Other staff members received low doses; staff positioning is a key factor even with full personal protection.

Limits to keep in mind

Single-centre dosimetry study of 41 procedures with a mobile C-arm in an operating room, mostly standard EVAR; the abstract gives no dose values or statistics for staff.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.

Prepared November 3, 2026.