In plain language
In 710 supraventricular tachycardia (SVT) ablations by 32 women electrophysiologists in 12 European centres, a near-zero fluoroscopy approach kept estimated annual operator dose far below the 1 mSv pregnancy limit. Doses were estimated from patient dose-area product (DAP), not measured, and covered SVT cases only.
At a glance
- Type of study
- Original research, Prospective cohort study
- Who was studied
- Electrophysiologists, Patients
- Size
- n = 710 procedures (by 32 operators)
- Where
- Italy, Spain, Croatia, Germany, Switzerland
- Topics
- Pregnancy and reproductive healthWomen in the fieldDose reduction techniquesDosimetry and monitoringWorkforce and careersPatient dose
- Summary based on
- the full text
What it found
Estimated mean annual operator effective dose under fluoroscopy minimization was very low, and no operator reached the 1 mSv pregnancy limit.
Key figures: 9.34 ± 15.9 µSv per year (annual DAP 46.7 ± 79.5 Gy·cm²)
Even under worst-case distance and angulation assumptions, estimated annual dose stayed below 1 mSv.
Key figures: 448.32 ± 763.2 µSv
Most procedures were performed with no fluoroscopy at all.
Key figures: 555/710 (78%) zero fluoroscopy; 33/710 (5%) near-zero
Per-procedure DAP did not differ by operator lifetime experience.
Key figures: 0.76 vs 2 vs 1.6 Gy·cm², P = 0.66
High acute success with few complications.
Key figures: 693/710 (98%)
Limits to keep in mind
Operator dose was model-derived from patient DAP rather than measured with dosimeters, and only SVT ablations were captured, not operators' full case mix. Non-randomized registry without a conventional-fluoroscopy comparison.
Related research summaries
- Radiation Exposure, Training, and Safety in Cardiology (2024, Narrative review)
- Risk of ionizing radiation in pregnancy: just a myth or a real concern? (2022, Narrative review)
- Occupational radiation exposure in the electrophysiology laboratory with a focus on personnel with reproductive potential and during pregnancy: A European Heart Rhythm Association (EHRA) consensus document endorsed by the Heart Rhythm Society (HRS) (2018, Guideline or consensus statement)
- Radiation safety program for the cardiac catheterization laboratory (2011, Guideline or consensus statement)
- 2018 ACC/HRS/NASCI/SCAI/SCCT Expert Consensus Document on Optimal Use of Ionizing Radiation in Cardiovascular Imaging: Best Practices for Safety and Effectiveness: A Report of the American College of Cardiology Task Force on Expert Consensus Decision Pathways (2019, Guideline or consensus statement)
How this summary was made
ORSIF prepared this summary with AI assistance from the full text of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.
Prepared November 5, 2026.