Search

238 results for “eye lens dose limit”.

Results

  1. Research summary

    Interventional Committee of the Society of Cardiovascular Interventions. Occupational hazards of interventional cardiologists: prevalence of orthopedic health problems in contemporary practice

    Limits: Web-based self-reported yes/no survey with about a 26% response rate (424 of over 1,600), raising response bias; no control group and no objective confirmation of diagnoses or apron use.

    orsif.org/research/interventional-committee-of-the-society-of-cardiovascular-interventions

  2. State Rules Map

    State-by-State Radiation Safety Rules for Fluoroscopy Teams

    …10 CFR Part 20 and replace it with a graded approach to dose management. The proposal keeps the dose limits, including 150 mSv a year for the lens of the eye. Agreement States would generally need to…

    orsif.org/guidelines/us/states.html

  3. International guidelines

    Mexico: radiation protection rules for healthcare workers

    Whole body: 50 mSv/year, 100 mSv/5 years. Lens of the eye: 150 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 2 mSv to fetus

    orsif.org/guidelines/international/countries.html

  4. International guidelines

    Turkey: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year. Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  5. International guidelines

    South Africa: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year. Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  6. FAQ

    Which states have the strictest radiation protection regulations?

    …equipment. No state has adopted the 20 millisievert eye lens limit recommended by the International Commission on Radiological Protection.

    orsif.org/faqs

  7. Research summary

    Occupational hazards of interventional cardiologists: prevalence of orthopedic health problems in contemporary practice

    Limits: Self-reported yes/no web survey with roughly a 26% response rate (424 of over 1,600 members), so responder and recall bias are likely; no control group or objective confirmation of diagnoses.…

    orsif.org/research/occupational-hazards-of-interventional-cardiologists-prevalence-of-orthopedic

  8. International guidelines

    Brazil: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year (5-year average). Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  9. International guidelines

    India: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year (5-year average). Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  10. International guidelines

    China: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year. Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  11. International guidelines

    France: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year. Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  12. International guidelines

    Argentina: radiation protection rules for healthcare workers

    Whole body: 20 mSv/year (5-year average). Lens of the eye: 20 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 1 mSv to fetus

    orsif.org/guidelines/international/countries.html

  13. International guidelines

    Canada: radiation protection rules for healthcare workers

    Whole body: 50 mSv/year, 100 mSv/5 years (20 mSv avg). Lens of the eye: 50 mSv/year (reduced from 150 mSv). Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 4 mSv remainder of pregnancy

    orsif.org/guidelines/international/countries.html

  14. Research summary

    SCAI Multi-Society Position Statement on Occupational Health Hazards

    Compliance with shielding should not be optional; hospitals should fund protective devices including disposable shielding pads, and real-time dose monitoring should become standard.

    orsif.org/research/scai-multi-society-position-statement-on-occupational-health-hazards

  15. International guidelines

    South Korea: radiation protection rules for healthcare workers

    Whole body: 50 mSv/year, 100 mSv/5 years. Lens of the eye: 15 mSv/year. Skin: 500 mSv/year. Hands and feet: 500 mSv/year. Pregnancy: 2 mSv during pregnancy

    orsif.org/guidelines/international/countries.html

  16. Research summary

    The occupational effects of interventional cardiology: results from the WIN for Safety survey

    Limits: Voluntary web-based survey with self-reported health outcomes, no control group and possible response bias; the abstract gives no response rate and cannot establish that conditions were caused…

    orsif.org/research/the-occupational-effects-of-interventional-cardiology-results-from-the-win-for

  17. Research summary

    SCAI/ASE/HRS/SIR/SVS Expert Consensus Statement on Enhanced Radiation Protection: Time for Mandatory and Urgent Action

    Limits: Expert consensus statement summarised from its abstract only; it presents recommendations rather than new data, and no quantitative evidence is given in the abstract.

    orsif.org/research/scai-ase-hrs-sir-svs-expert-consensus-statement-on-enhanced-radiation-protection

  18. Research summary

    Occupational Health Hazards in the Cardiac Catheterization Laboratory: Results of the 2023 SCAI Survey

    Limits: Self-reported cross-sectional survey with an 8% response rate, unverified procedure volumes, and possible survivorship and reporting bias; the 2014 and 2023 samples differ in composition,…

    orsif.org/research/occupational-health-hazards-in-the-cardiac-catheterization-laboratory-results-of

  19. State rules

    Wyoming Radiation Safety Rules for Fluoroscopy Teams

    …hospitals' radioactive materials directly. The only legal dose limits for fluoroscopy staff come from Wyoming OSHA's adoption of 29 CFR 1910.1096, which counts the lens of the eye inside the 1.25 rem…

    orsif.org/guidelines/us/states/wyoming

  20. International guidelines

    International Radiation Safety Guidelines for Healthcare Workers

    EU/Euratom. US (Reference). Whole Body Effective dose. 20 mSv/yr avg Max 50 mSv/yr. 20 mSv/yr Or 100 mSv/5yr. 50 mSv/yr 2.5x higher. Eye Lens Equivalent dose. 20 mSv/yr avg Reduced in 2011

    orsif.org/guidelines/international

2 studies in the members' research library match. Join free to search them