Search

209 results for “dosimeter”, 126 in Research summaries.

Results

  1. Research summary

    Radiation-Induced DNA Damage in Operators Performing Endovascular Aortic Repair

    Leg-level dosimeter readings were higher than chest readings, and about twice as high in complex versus standard EVAR. (≈2-fold higher leg exposure; P<0.0001)

    orsif.org/research/radiation-induced-dna-damage-in-operators-performing-endovascular-aortic-repair

  2. Research summary

    Occupational radiation exposure of radiologic technologists in Interventional neuroradiology

    …to a year, mostly fixed-position rather than worn dosimeters; experimental measurements used a head-only phantom, single unrepeated readings, and a monitor that may have been saturated by pulsed high…

    orsif.org/research/occupational-radiation-exposure-of-radiologic-technologists-in-interventional

  3. Research summary

    Investigating the Performance of X-ray Protection of Various Elements and Alloy Compounds in Aprons for Interventional Radiology

    …phantoms and a single modelled room, validated against one dosimeter measurement (calculated 140.74 µGy vs measured 111.4 µGy). Shields were compared at fixed 0.5 mm thickness, and several tungsten…

    orsif.org/research/investigating-the-performance-of-x-ray-protection-of-various-elements-and-alloy

  4. Research summary

    From whole-body dosimetry to local dose assessment: a 3-y experience in interventional practice

    …factors differed by specialty, so estimates from chest badges are a stopgap, not a substitute for dedicated eye and extremity dosimetry.

    orsif.org/research/from-whole-body-dosimetry-to-local-dose-assessment-a-3-y-experience-in

  5. Research summary

    Three-Dimensional Fusion Computed Tomography Decreases Radiation Exposure, Procedure Time, And Contrast Use During Fenestrated Endovascular Aortic Repair

    Staff dose was not measured because of inconsistent badge use; reduced staff exposure was only assumed.

    orsif.org/research/three-dimensional-fusion-computed-tomography-decreases-radiation-exposure

  6. Research summary

    Occupational Health Hazards in the Cardiac Catheterization Laboratory: Results of the 2023 SCAI Survey

    …buy-in as main barriers; 17% admitted not wearing badges to avoid exposure thresholds. (<15% adoption; cost 83%, administrative buy-in 71%)

    orsif.org/research/occupational-health-hazards-in-the-cardiac-catheterization-laboratory-results-of

9 studies in the members' research library match. Join free to search them