In plain language
In a cadaver model of percutaneous nephrolithotomy (PCNL), a lead apron, low pulse rates and low-dose fluoroscopy each sharply reduced estimated uterine dose to the urologist, suggesting pregnant surgeons could keep operating under the 1 mSv fetal limit; this measures dose, not health outcomes.
At a glance
- Type of study
- Original research, Phantom or simulation study
- Who was studied
- Urologists, Phantom or simulation (no people)
- Topics
- Pregnancy and reproductive healthWomen in the fieldPersonal protective equipmentDose reduction techniquesDosimetry and monitoring
- Summary based on
- the abstract
What it found
A 0.35-mm lead apron cut uterine dose by 94%; thicker aprons reduced dose further.
Key figures: 94% (P < .001); 0.50 mm further 12%, 0.70 mm further 47%
Reducing pulse rate from 30 to 1 pps reduced uterine dose by 96%.
Key figures: 96% (P < .001)
Low-dose fluoroscopy setting reduced uterine dose by 56%.
Key figures: 56% (P < .001)
At conventional settings, the 1 mSv fetal limit would be reached after 12 PCNLs without lead or 189 with a 0.35-mm apron.
Key figures: 12 PCNLs without lead; 189 PCNLs with 0.35-mm apron
Combining shielding with 1 pps and low-dose fluoroscopy allowed over 6000 cases below 1 mSv uterine exposure.
Key figures: >6000 cases
Limits to keep in mind
Cadaver simulation with two cadavers and an ion chamber rather than real pregnant surgeons; case estimates assume 5 minutes of fluoroscopy per PCNL and single geometry.
Related research summaries
- Occupational Protection in Interventional Radiology. A Joint Guideline of the Cardiovascular and Interventional Radiological Society of Europe and the Society of Interventional Radiology (2026, Guideline or consensus statement)
- Radiation Exposure, Training, and Safety in Cardiology (2024, Narrative review)
- Risk of ionizing radiation in pregnancy: just a myth or a real concern? (2022, Narrative review)
- Radiation safety program for the cardiac catheterization laboratory (2011, Guideline or consensus statement)
- Body Surface Radiation Exposure in Interventional Echocardiographers During Structural Heart Disease Procedures (2023, Dosimetry measurement study)
How this summary was made
ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.