Research summary, original research, 2017

Peripherally inserted central catheters: dependency of radiation exposure from puncture site and level of training

Jonczyk M, Gebauer B, Schnapauff D, Rotzinger R, Hamm B, Collettini F. Acta radiologica (Stockholm, Sweden : 1987). 2017

Read the original paper

In plain language

In 681 PICC placements, experienced radiologists used slightly less fluoroscopy time than juniors, with no significant difference in dose area product, and left-sided access shortened fluoroscopy time. Staff dose was not measured.

At a glance

Type of study
Original research, Retrospective cohort study
Who was studied
Interventional radiologists, Trainees, Patients
Size
n = 681 patients
Summary based on
the abstract

What it found

  • Senior radiologists used significantly less fluoroscopy time than juniors during PICC placement.

    Key figures: senior = 0.43 s, junior = 0.53 s, P = 0.041

  • Dose area product did not differ significantly between senior and junior radiologists.

    Key figures: senior = 56.3 µGy*m2, junior = 60.6 µGy*m2, P = 0.151

  • Left-sided PICC access reduced median fluoroscopy time compared with right-sided access.

    Key figures: 60.9% reduction (left = 0.45 s, right = 1.15 s, P = 0.010)

Limits to keep in mind

Single retrospective cohort measuring patient dose indices (fluoroscopy time, dose-area product (DAP)) rather than staff dose; fluoroscopy times are very short, so absolute differences are small, and country and setting details are not given in the abstract.

How this summary was made

ORSIF prepared this summary with AI assistance from the abstract of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.

Prepared November 3, 2026.