In plain language
In 230 structural heart procedures at one US center, under-lead pelvic dose to interventional echocardiographers was almost always undetectable. Chest-level dose was higher in mitral and tricuspid cases, and was associated with half-shield-only use and head-of-bed positioning.
At a glance
- Type of study
- Original research, Dosimetry measurement study
- Who was studied
- Other physicians, Mixed lab staff
- Size
- n = 230 procedures
- Where
- United States
- Topics
- Pregnancy and reproductive healthDosimetry and monitoringRoom shielding and protective devicesPersonal protective equipmentWomen in the fieldWorkforce and careersMusculoskeletal injury and ergonomics
- Summary based on
- the full text
What it found
Under-lead pelvic dose was undetectable in nearly all procedures. The modeled fetal dose over a full pregnancy was far below the International Commission on Radiological Protection (ICRP) 1 mSv limit.
Key figures: 0 μSv in 98.7% of cases; ∼2.3 μSv estimated for full pregnancy
Half-shield-only use was independently associated with higher chest-level dose than adjustable full or combination shielding. This was the largest effect in the model.
Key figures: adjusted fold change 3.78; 95% confidence interval (CI): 1.51-9.44; P = 0.005
Chest-level dose to interventional echocardiographers rose from left atrial appendage occlusion (LAAO) to mitral to tricuspid interventions.
Key figures: median 9.0 μSv (IQR: 3.2-21.0) LAAO, 18.0 μSv (7.5-43.5) TMVI, 36.0 μSv (16-116) TTVI; P < 0.001
Head-of-bed positioning was independently associated with about twofold higher chest-level dose. The estimate rests on few cases.
Key figures: adjusted fold change 2.17; 95% CI: 1.06-4.43; P = 0.035, n = 17
Interventional echocardiographers received much higher chest-level doses than sonographers during the same procedures.
Key figures: 10- to 50-fold higher; P < 0.001
Limits to keep in mind
Single-center observational study using one upper-arm dosimeter site, with no eye, thyroid or hand dosimetry, two fluoroscopy systems, few head-of-bed cases (n = 17) and no correction for multiple comparisons. The fetal dose is a modeled estimate from a suprapubic under-lead dosimeter, not a measured fetal dose.
Related research summaries
- SCAI Multi-Society Position Statement on Occupational Health Hazards (2020, Guideline or consensus statement)
- Radiation Realities: Radiation Safety Practices and Awareness Among Interventional Echocardiographers in the United States (2025, Cross-sectional survey)
- Occupational Health Hazards in the Cardiac Catheterization Laboratory: Results of the 2023 SCAI Survey (2025, Cross-sectional survey)
- Radiation Exposure, Training, and Safety in Cardiology (2024, Narrative review)
- Risk of ionizing radiation in pregnancy: just a myth or a real concern? (2022, Narrative review)
How this summary was made
ORSIF prepared this summary with AI assistance from the full text of the paper. A program then checked that the passage supporting each finding appears word for word in that source. A person has not yet reviewed each summary, so read the original before relying on a number. ORSIF summarizes research and does not endorse any product or company. Report a problem with this summary.
Prepared November 5, 2026.