Wassef AWA, Hiebert B, Rvandi A, et al. Radiation Dose Reduction In The Cardiac Catheterization Laboratory Utilizing A Novel Protocol. JACC Cardiovasc Intervv. 2014 May; 7(5):550-557.

This study reports the results a novel radiation reduction protocol (RRP) system for coronary angiography and interventional procedures and the determinants of radiation dose. A total of 605 patients underwent coronary angiography (309 before RRP and 296 after RRP), with 129 (42%) and 122 (41%) undergoing percutaneous coronary interventions before and after RRP, respectively. With RRP, a 48% dose reduction (1.07 ± 0.05 Gy vs. 0.56 ± 0.03 Gy, p < 0.0001) was obtained, 35% with 15 FPS RRP (0.70 ± 0.05 Gy, p < 0.0001) and 62% with 7.5 FPS RRP (0.41 ± 0.03 Gy, p < 0.001). Similar dose reductions for diagnostic angiograms and percutaneous coronary interventions were noted.